User Manual RT-C02-1

TRUE PHANTOM SOLUTIONS User ManualSectional Mouse for X-Ray CT[RT-C02] VERSION 2.4 ■ 1 May 2026 [email protected] ■ www.truephantom.com

 Open the catalog to page 1
User Manual RT-C02-2

TRUE PHANTOM SOLUTIONS INC.

 Open the catalog to page 2
User Manual RT-C02-3

TRUE PHANTOM SOLUTIONS INC. Description Sectional Mouse Phantom for X-Ray/CT is designed based on the average anatomy of a mouse, and it is sliced into four 5 mm thick segments. The phantom can be used for medical imaging research and development, testing, and calibration-related work. It can be customized in terms of size, shape, internal features, and properties to fit the needs of a wide variety of biomedical research projects. Anatomy Full Skeleton Heart Lungs Diaphragm Liver Kidneys Pancreas Spleen

 Open the catalog to page 3
User Manual RT-C02-4

TRUE PHANTOM SOLUTIONS INC. Side View Side View Perspective View

 Open the catalog to page 4
User Manual RT-C02-5

TRUE PHANTOM SOLUTIONS INC. Technical Properties Averaged HU Value Density [g/cm³] Soft Tissue Materials Used Soft tissue and organs: Composition of urethane-based soft resin Synthetic bones: Patented ceramic-reinforced epoxy-based composite material Size and Weight of the Phantom Phantom Size: 2 x 4 x 1 Inches, Weight: 0.5 Lbs (approx.). Shipment Size: 10 x 8 x 6 Inches, Weight: 3 Lbs (approx.) Included In Order Sectional Mouse Phantom User Manual/Assembly Instructions 2-Year Warranty & Unlimited Customer Service Hard Carry Case 5|Page

 Open the catalog to page 5
User Manual RT-C02-6

TRUE PHANTOM SOLUTIONS INC. RT-C02 | User Manual The phantom is fabricated based on the anatomy of the real human body. It can be scanned per the standard protocols used while positioning a real person. The phantom can be put on horizontal and vertical positions for scanning purposes. Anterior, Lateral, and Posterior techniques can also be performed. • The phantom is made of urethane-based material and should be protected from direct exposure to any intense UV light. • The experiments conducted on the phantom can be performed in a sunny lab, but leaving the phantom under direct sunlight for weeks...

 Open the catalog to page 6
User Manual RT-C02-7

TRUE PHANTOM SOLUTIONS INC. RT-C02 | User Manual • The phantom is water-resistant and can be cleaned after use. It is ideal for cleaning it either with water or with soapy water. It is also quite resistant to chemicals, but if stronger solvents are meant to be used with the phantom, we recommend doing a small test on the bottom part of the neck or legs. The phantom should be placed on its belly, and the chosen solvent can be applied on a small, selected surface of the phantom for a few hours. If there is no visible effect on the phantom's surface, it is safe to assume that the phantom is resistant...