Overview: The TS-10A 4” Alternating Air Mattress & Pump System by True Source Technology Co., Ltd. is designed to prevent pressure ulcers. It features a power unit with adjustable comfort settings, an auto firm mode for nursing, and an audible mute button for alarms. The system is cost-effective and manufactured in Taiwan.
Power Unit Features:
  • Comfort Setting/Knob Control: Allows adjustment of mattress hardness/softness from 1 to 10, supporting a weight range of 30kg to 120kg.
  • Auto Firm Mode: Temporarily hardens the mattress for nursing ease, reverting after 30 minutes to prevent pressure ulcers.
  • Audible Mute Button: Mutes alarms for low pressure or power failure, with reset required to restore sound.
  • Pressure Monitoring LED: Indicates pump activity and mattress inflation status.
Air Mattress Features:
  • Design: 4” mattress with 20 air cells for intensive protection, especially for hips and chest.
  • Friction and Shear Prevention: Coverlet made from non-toxic PU-film reduces skin injury.
  • Elastic Bands: Large bands at corners for secure mattress fixing.
  • Head End Design: No alternating air cells at the head end for increased comfort.
Safety and Durability:
  • Shock Absorption: Vibration isolation through a suspension system and rubber shock absorbers.
  • Power Safety: Class I electrical device with a 3-pin detachable power cord.
  • Double-Fuse Design: Ensures safety during long-term operation, with easy fuse replacement.
  • Fire Safety: ABS external cover with V-0 fire classification.
  • Filter Foam: Visible and replaceable without opening the compressor.
Specifications:
  • Control Unit: AC110V/60Hz or AC220-240V/50Hz, max power consumption of 10W, dimensions L26*W8*H13 cm, weight approx. 1.5 kg.
  • Air Mattress: Dimensions L200*W85*H10 cm, weight approx. 3.8 kg, load capacity 30-120kg, materials include Nylon/TPU and Nylon/PVC.
Manufacturer Information: True Source Technology Co., Ltd., located in Taipei, Taiwan. Contact via phone or fax for more details.
See more

Catalog excerpts

TS-10A-1

Anti-pressure Ulcer Cost Effective - High Specifications / Made in Taiwan Power Unit:Safety Power Saving Aesthetic i □ Comfort Setting /Knob Control: Automatically provides a suitable alternating pressure according to the selected comfort setting. The air mattress can be easily adjusted to a proper hardness/softness ranging from 1 to 10. Loading weight:30kg - 120kg. Auto Firm Mode (Nursing) Button: During nursing, it can be difficult to turn a patient and nurse if the mattress is too soft. This can harden the mattress in the quickest way for easy nursing. However, after 30 minutes, the unit will forcefully resume the setting before the button is pressed in order to protect the patient from the risk of developing pressure ulcers because the mattress becomes too hard. Press the button when necessary. 3. Audible Mute Button: The alarm becomes audible when Low Pressure Alarm or Power Failure Alarm alerts problem occurrence. The alarm can be muted with this button when it is necessary to turn off the function of alarm sound. To restore the audible alarm function, you have to reset the power switch. 4. Pressure Monitoring LED Indicator: When the LED is flashing, this indicates that the pump is in the process of giving sufficient air to the mattress. When the LED is lit on, this indicates that the pump is inflating the mattress according to the selected comfort setting. If the LED is not lit on, this indicates that the mattress has reached to an air pressure according to the selected comfort setting. •KEasy operation & installation •^Safe external dual-fuse design •&3-PIN detachable power cord •^Alternating inflation & deflation electronically •^Low vibration, low noise, low power consumption •^No acute angle on the entire machine for the utmost safety Patented internal mechanism ^Filter foam is visible from the outside and easy to replace •^Sturdy double hook design •^Can be placed vertically/horizontally or hung on a hook.

 Open the catalog to page 1
TS-10A-2

Air Mattress: Comfort Ease Durability •^4” mattress, 20 air cells allowing shortened spacing between tubes, and providing more intensive protection for our most critical body parts Friction and Shear Prevention Coverlet Durable, deformation free & lightweight air cells Patented CPR design ^ Large scale elastic bands fixed on four corners •^The Air Tube connected to the power unit is protected by tube-cover. •^Head end 3 air cells no alternating Digital Control Power Unit Safety Power Management Wide Elastic Band for Mounting CPR Quick Deflation Valve Air Cells Overlap Closely Sleep with comfort...

 Open the catalog to page 2
TS-10A-3

Perfect dimensions: The length, width and height of the mattress is carefully designed to match the dimensions of most hospital beds, eliminating worries regarding the bed slipping or excessive gaps, which lead to feelings of insecurity. Comprehensive Safety Considerations  Mechanical shock absorption: The air inlet to the main compressor may introduce vibration; structurally, the inlet is supported by a suspension system and furnished with external rubber shock absorbers, enabling near perfect isolation of discomfort resulting from the vibration. Power safety management: Applying for electrical...

 Open the catalog to page 3
TS-10A-4

■ Continuously upgrading R&D capabilities: Retain existing merits, continuously improve defects, enhance collection of clinic information, absorb professional and relevant up-to-date know-how, and consider functional requirements of the product based on the company’s value that those most in need should receive the most pampering and care. * Operation Temperature : 10°C ~ 40°C ^Transport Temperature: -10C ~ 45°C (14°F ~113°F) * NO AP/APG Control Unit: Manufacturer: True Source Technology Co., Ltd. Address:4F., No.523, Chung-Chueng Rd., Hsin Tien City, Taipei Hsien 231, Taiwan (R.O.C.) Tel: +886-2-86671780...

 Open the catalog to page 4

All True Source Technology Co., Ltd. catalogs and technical brochures

  1. TS-508+

    2  Pages

  2. TS-508

    1  Page

  3. TS-505

    1  Page

  4. TS-106

    2  Pages

  5. TS-50U

    2  Pages

  6. TS-60A6

    2  Pages

  7. TS-10V

    1  Page

  8. TS-506

    2  Pages

  9. TS-105

    1  Page

  10. TS-305

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.