iProtin
2Pages

{{requestButtons}}

Catalog excerpts

iProtin - 1

Protin High-quality quantitative assays equivalent to laboratory methods Using iProtin system, all you need to do are: • Finger Blood, volume is 5 |jL only (one drop). • No need additional blood centrifugation or filter procedure. • Simple operation, easy to use. • Hand-held and portable (iProtin Reader) • Within 3 minutes to have result. For Chronic Lp(a) & ApoB are highly heritable biomarker independently associated with atherosclerotic cardiovascular diseade (ASCVD) used for cardiovascular diseases diagnosis and monitor. For Patient Replace the traditional venous blood collection with fingertip blood for testng, reducing the impact of blood collection. CRP* Lp(aK ApoB Specification Intended Use Sample Type Sample Volume Measuring time Measuring rage Sensitivity Storage Approved CRP Evaluation and Tracking of inflammation Whole Blood mixed with enhancer SpL 3 minutes 0.2-10 mg/dL LoQ= 0.1 mg/dL Room temperature for 1 year CE/FDA Lp(a) Risk Evaluation of CVD (Genetic) Whole Blood SpL 3 minutes 8.3 - 140.2 mg/dL LoQ= 5.83 mg/dL Room temperature for 1 year CE/FDA ApoB Risk Evaluation of CVD (Metabolic) Whole Blood mixed with enhancer SpL 40 Seconds 8.0-202.2 mg/dL LoQ= 8.01 mg/dL Room temperature for 1 year CE/FDA Test Range CRP Range 0.2 - 10 mg/dL (whole blood) Normal Range: < 1 mg/dL Abnormal Range: > 1 mg/dL The product has a one-year shelf life at room temperature. Lp(a) Range 10 - 140 mg/dL Normal Range: < 30 mg/dL The product has a one-year shelf life at room temperature. ApoB Range 10 - 200 mg/dL Normal Range for Males: 46 - 174 mg/dL Normal Range for Females: 46 - 142 mg/dL The product has a one-year shelf life at room temperature. Ultra-fast < 3 mins Bio-marker Detection • Hand-held IVD detector, suitable for clinics, long-term care centers, and home medical care. • Multiple biomarkers tested in one Reader • Accurate and reliable quantitative test results.

Open the catalog to page 1
iProtin - 2

CRP assay cartridge kit Cat No. TU0001A C€ Lp(a) assay cartridge kit Cat No. BMLPAP0110 FDA, ApoB assay cartridge kit Indicators of cardiovascular disease risk • C-reactive protein / High-sensitivity CRP • Lipoprotein (a) • Apolipoprotein B For individuals with chronic diseases and suboptimal health Cardiovascular diseases, abbreviated as ASCVD, can be assessed using diverse biomarkers. ApoB predicts low-density lipoprotein (LDL) levels with greater resistance to high triglyceride levels than traditional LDL-C tests. hsCRP aids in ASCVD risk assessment in infection-free patients. Meanwhile,...

Open the catalog to page 2

All Tst Biomedical Electronics catalogs and technical brochures

  1. iPro-Lab

    2 Pages