1. Catalogs
  2. Tsunami Medical
  3. INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM
video corpo

INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM

INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM
1 / 244 PagesView full catalog

INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM

Product catalog summary
Overview: The document provides comprehensive specifications and guidelines for orthopedic implants and surgical instruments, focusing on materials, dimensions, and usage procedures.
Implant Trials: It details Ortigia Implant Trials with specific dimensions and angles, highlighting materials like Stainless Steel INOX 304/17-4 ph. These implants feature built-in fixation and are part of the first generation.
Materials: The primary materials include Stainless Steel INOX 304/17-4 ph and Nylon PA12, with a dimensional tolerance of ± 2 mm, ensuring durability and precision.
Instrument Sets: Various surgical sets such as OLIF, PLIF, and TLIF are described, each containing specific instruments like implant holders and curettes, designed for ease of use and adaptability.
Key Features: Instruments and implants are noted for their 'First Generation' and 'Expandable' designs, emphasizing the importance of selecting the correct implant height and angle.
Usage Instructions: Detailed instructions are provided for assembling and using instruments like the Salina and Pianosa Implant Holders, ensuring proper surgical application.
Conclusion: The document serves as a guide for selecting and using orthopedic implants and instruments, stressing precision and adaptability in surgical applications.
VENTOTENE Instruments Overview: Specifications and procedures for VENTOTENE surgical instruments are detailed, with each instrument identified by a unique code and primarily made from Stainless Steel INOX 304/17-4 ph.
Specifications: Instruments are described with dimensions and tolerances, including tools like screwdrivers, torque wrenches, and rod benders.
Materials: Stainless Steel INOX 304/17-4 ph is the primary material, with some instruments incorporating silicone and nylon for flexibility and strength.
Procedures: Procedures for 'OPEN' and 'MIS' techniques are outlined, ensuring correct instrument application during surgeries.
Key Instruments and Features: Includes screwdrivers, torque wrenches, probes, and rod benders, with features like fast connection handles and trays for organization.
General Instruments: Emphasizes first-generation design with built-in fixation and expandable features, crucial for implantable devices.
Conclusion: The guide ensures medical professionals can effectively use VENTOTENE instruments, highlighting specifications and procedural applications.
Cleaning and Sterilization Instructions: Instructions for cleaning, inspecting, disassembling, and sterilizing TSUNAMI MEDICAL instruments are provided, emphasizing validated reprocessing methods.
Warnings and Precautions: Reusable instruments should not be used with TSE infective tissue, and aggressive decontamination agents are discouraged.
Cleaning: Manual and automated cleaning methods are detailed, requiring protective clothing and specific tools.
Inspection: Instruments should be inspected for soil, corrosion, and damage before sterilization.
Packaging and Sterilization: Steam autoclave sterilization is recommended, with specific cycle parameters, and flash sterilization is not advised.
Storage Before Use: Post-sterilization storage should be in a dust-free, dry place, with shelf life defined by the healthcare facility.
References: The document references ISO standards for sterilization and packaging.
Product Warranty and Non-Conformity: Tsunami Medical offers a warranty against defects, with a process for reporting complaints.
See more

Catalog excerpts

INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-1

I N S T R U M E N T S C ATA LO G U E INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM

 Open the catalog to page 1
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-5

ALIF Surgery Set OLIF Surgery Set PLIF Surgery Set IDF-AFF Surgery Set IFS Surgery Set G E N E R A L I N S T R U M E N T S TLIF IDF-AFF IFS VENTOTENE GENERAL INSTRUMENTS INSTRUCTIONS FOR USE

 Open the catalog to page 5
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-8

• First Generation S u r g e r y S e t Fu l l D i n Capraia Implant Holder (Dismantable) BOK-CS-02 Capraia Implant Holder Shaft BOK-CS-01 Capraia Implant Holder 121 mm Implant Holder Shaft Implant Holder Assembly Scheme: Insert the Shaft in the Holder and screw the knob. Connect the Cage to the coupling. Capraia Implant Holder Implant Holder body with soft silicone handle • Stainless Steel INOX 304/17-4 ph • Silicone Implant Holder Shaft

 Open the catalog to page 8
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-9

• Built-In Fixation S u r g e r y S e t Fu l l D i n Capraia-Z Implant Holder (Dismantable) BOK-CSZ-03 Capraia-Z Pins Expansion Shaft BOK-CSZ-02 Capraia-Z Implant Holder Shaft Pins Expansion Shaft BOK-CSZ-01 Capraia-Z Implant Holder Implant Holder Shaft Implant Holder 1. Insert the Holder Shaft. 2. Screw the knob to lock the cage. 3. Insert the Pins Expansion Shaft. 4. Screw the knob to expand the pins. Capraia-Z Implant Holder (Dismantable) Implant Holder body with soft silicone handle • Stainless Steel INOX 304/17-4 ph • Silicone Implant Holder Shaft Pins Expansion Shaft

 Open the catalog to page 9
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-10

• First Generation • Built-In Fixation Materials • Stainless Steel INOX 304/17-4 ph • Silicone **Dimensional tolerance

 Open the catalog to page 10
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-11

• First Generation • Built-In Fixation S u r g e r y S e t Fu l l D i n One Side Squared Curette One Side Squared Curette BOK-CS-04 Materials • Stainless Steel INOX 304/17-4 ph • Silicone **Dimensional tolerance ± 2 mm

 Open the catalog to page 11
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-12

• First Generation • Built-In Fixation Materials • Stainless Steel INOX 304/17-4 ph **Dimensional tolerance ±

 Open the catalog to page 12
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-13

• First Generation • Built-In Fixation Materials • Stainless Steel INOX 304/17-4 ph **Dimensional tolerance ± 2 mm

 Open the catalog to page 13
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-14

• First Generation • Built-In Fixation S u r g e r y S e t Fu l l D i n Vertebral Body Perforator Vertebral Body Perforator BOK-CS-08 Materials • Stainless Steel INOX 304/17-4 ph • Silicone **Dimensional toleranc

 Open the catalog to page 14
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-15

• First Generation • Built-In Fixation Components: 1 Assembly Scheme: Insert the Screw in the Holder. Distraction Screwdriver BOK-CS-05 Materials • Stainless Steel INOX 304/17-4 ph • Silicone **Dimensional tolerance ± 2 mm

 Open the catalog to page 15
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-16

• First Generation • Built-In Fixation BOK-CS-10-12-14-16 Materials • Stainless Steel INOX 304/17-4 ph

 Open the catalog to page 16
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-17

• First Generation • Built-In Fixation S u r g e r y S e t Fu l l D i n Capraia Implant Trial Square Materials • Stainless Steel INOX 304/17-4 ph ** Choose preferred height and dimension and use them instead of the asterisks to get the final eference. BOK-CS-0405S Capraia Implant Trial 4-5 Small (12x12mm) Capraia Implant Trial 4-5 Medium (14x14mm) Capraia Implant Trial 4-5 Large (16x16mm)

 Open the catalog to page 17
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-18

• First Generation • Built-In Fixation Capraia Implant Trial 6-7 Small (12x12mm) Capraia Implant Trial 6-7 Medium (14x14mm) Capraia Implant Trial 6-7 Large (16x16mm) Capraia Implant Trial 8-9 Small (12x12mm) Capraia Implant Trial 8-9 Medium (14x14mm) Capraia Implant Trial 8-9 Large (16x16mm)

 Open the catalog to page 18
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-19

• First Generation • Built-In Fixation S u r g e r y S e t Fu l l D i n Capraia Implant Trial Rectangular Materials • Stainless Steel INOX 304/17-4 ph ** Choose preferred height and dimension and use them instead of the asterisks to get the final reference. BOK-CS-0405WS Capraia Implant Trial 4-5 Small (14x12mm) Capraia Implant Trial 4-5 Medium (16x14mm) Capraia Implant Trial 4-5 Large (18x16mm)

 Open the catalog to page 19
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-20

• First Generation • Built-In Fixation Capraia Implant Trial 6-7 Small (14x12mm) Capraia Implant Trial 6-7 Medium (16x14mm) Capraia Implant Trial 6-7 Large (18x16mm) Capraia Implant Trial 8-9 Small (14x12mm) Capraia Implant Trial 8-9 Medium (16x14mm) Capraia Implant Trial 8-9 Large (18x16mm)

 Open the catalog to page 20
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-21

• First Generation S u r g e r y S e t Fu l l D i n Capraia Implant Trial Rasp Materials • Stainless Steel INOX 304/17-4 ph ** Choose preferred height and dimension and use them instead of the asterisks to get the final eference. BOK-CS-R0405S Capraia Implant Trial Rasp 4-5 Small (12x12mm) Capraia Implant Trial Rasp 4-5 Medium (14x14mm) Capraia Implant Trial Rasp 4-5 Large (16x16mm)

 Open the catalog to page 21
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-22

• First Generation Capraia Implant Trial Rasp 6-7 Small (12x12mm) Capraia Implant Trial Rasp 6-7 Medium (14x14mm) Capraia Implant Trial Rasp 6-7 Large (16x16mm) Capraia Implant Trial Rasp 8-9 Small (12x12mm) Capraia Implant Trial Rasp 8-9 Medium (14x14mm) Capraia Implant Trial Rasp 8-9 Large (16x16mm)

 Open the catalog to page 22
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-23

• Built-In Fixation S u r g e r y S e t Fu l l D i n Capraia-Z Implant Trial Rasp Square Instrument Ref. Code: Materials • Stainless Steel INOX 304/17-4 ph ** Choose preferred height and dimension and use them instead of the asterisks to get the final eference. BOK-CSZ-R0405WS Capraia-Z Implant Trial Rasp 4-5 Small (12x12mm) Capraia-Z Implant Trial Rasp 4-5 Medium (14x14mm) Capraia-Z Implant Trial Rasp 4-5 Large (16x16mm)

 Open the catalog to page 23
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-24

• Built-In Fixation Capraia-Z Implant Trial Rasp 6-7 Small (12x12mm) Capraia-Z Implant Trial Rasp 6-7 Medium (14x14mm) Capraia-Z Implant Trial Rasp 6-7 Large (16x16mm) Capraia-Z Implant Trial Rasp 8-9 Small (12x12mm) Capraia-Z Implant Trial Rasp 8-9 Medium (14x14mm) Capraia-Z Implant Trial Rasp 8-9 Large (16x16mm)

 Open the catalog to page 24
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-25

• Built-In Fixation S u r g e r y S e t Fu l l D i n Capraia-Z Implant Trial Rasp Recatangular Instrument Ref. Code: Materials • Stainless Steel INOX 304/17-4 ph ** Choose preferred height and dimension and use them instead of the asterisks to get the final eference. BOK-CSZ-R0405WS Capraia-Z Implant Trial Rasp 4-5 Small (14x12mm) Capraia-Z Implant Trial Rasp 4-5 Medium (16x14mm) Capraia-Z Implant Trial Rasp 4-5 Large (18x16mm)

 Open the catalog to page 25
INSTRUMENTS CATALOGUE INTERBODY FUSION CAGES VENTOTENE SCREW & ROD SYSTEM-26

• Built-In Fixation Capraia-Z Implant Trial Rasp 6-7 Small (14x12mm) Capraia-Z Implant Trial Rasp 6-7 Medium (16x14mm) Capraia-Z Implant Trial Rasp 6-7 Large (18x16mm) Capraia-Z Implant Trial Rasp 8-9 Small (14x12mm) Capraia-Z Implant Trial Rasp 8-9 Medium (16x14mm) Capraia-Z Implant Trial Rasp 8-9 Large (18x16mm)

 Open the catalog to page 26

All Tsunami Medical catalogs and technical brochures

  1. CAPRAIA

    4  Pages

  2. ALICUDI-J

    4  Pages

  3. ALICUDI

    4  Pages