1. Catalogs
  2. Tuttnauer
  3. Medical Waste Autoclaves

Medical Waste Autoclaves

Medical Waste Autoclaves
1 / 12 PagesView full catalog

Medical Waste Autoclaves

Product catalog summary
Overview: The document provides a comprehensive overview of Tuttnauer's medical waste autoclaves, highlighting their cost-effectiveness, environmental safety, and advanced features for sterilizing medical waste in hospitals and medical centers.
Cost-Effectiveness: The autoclaves allow for on-site waste treatment, reducing the need for transportation to external facilities, thus lowering costs and liability. They offer a modest price and operating cost, enabling quicker cost recovery.
Environmental Safety: The process is chemical-free and radiation-free, ensuring a clean and environmentally safe technology for waste treatment.
Key Features: The autoclaves are equipped with a strong vacuum pump for effective air removal, fast cooling cycles, and specialized loading carts for safe waste transfer. They also include pre-vacuum air sterilization and thermal sterilization processes to ensure the air is sterile and safe.
Waste Treatment Process: The process involves temporary waste storage, segregation and identification, sterilization by autoclaving at high pressure and temperature, optional compacting, shredding, and safe disposal in municipal landfills.
Advanced Control Systems: Tuttnauer offers sophisticated control systems with features like multi-color touch screens, real-time remote monitoring, and automatic recording of cycle information. The systems support multiple languages and provide detailed reporting capabilities.
Safety Features: The autoclaves include door safety mechanisms, pressure relief valves, emergency shut-off switches, and double independent monitoring systems to ensure safe operation.
Models and Specifications: The document lists various models with different chamber dimensions and volumes, catering to different needs from small to large medical centers.
Compliance and Standards: Tuttnauer's autoclaves comply with international standards and directives, including EN 285, DIN 58951-2, and ISO 9001, ensuring high-quality and safe waste treatment solutions.
Company Profile: Tuttnauer has over 85 years of experience in sterilization and infection control, supplying products to over 110 countries and recognized globally as a leader in the field.
See more

Catalog excerpts

Medical Waste Autoclaves-1

Your Sterilization & Infection Control Partners •£•) Medical Waste Autoclaves

 Open the catalog to page 1
Medical Waste Autoclaves-2

Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small, medium and large hospitals. Tuttnauer steam autoclaves are a safe cost-effective alternative for servicing your medical waste needs making it easier to dispose medical waste and empowering you to treat waste close to its sourceat a considerably lower price than expensive incinerator waste treatment technologies. Medical Waste Autoclaves Cost-Effective • Easy on-site installation removes need to transport waste to an external treatment facility...

 Open the catalog to page 2
Medical Waste Autoclaves-3

Medical Waste Autoclaves Strong Vacuum Pump Specialized Loading Cart for Waste Transfer The built-in vacuum pump produces a strong vacuum that ensures proper air removal for excellent sterilization results. A specialized loading cart for safely transferring medical waste is available with the following important features: • The bottom shelf has no holes to prevent liquid from leaking out of the cart • The bottom shelf has a drain to enable collection of any liquid waste into a container • All the shelves have a barrier around their perimeter to prevent waste from falling off the cart Inactivation...

 Open the catalog to page 3
Medical Waste Autoclaves-4

Medical Waste Treatment Process Waste Segregation & Identification Temporary Waste Storage Effective and safe management of medical waste begins with segregation and identification of waste. Segregation usually takes place nearby or at the source where the waste is generated. Waste is commonly identified by sorting the waste into sealed colour-coded plastics bags or containers. Sometimes is is necessary to temporarily store waste when it is not subject to immediate processing or when there are delays in the waste treatment processing. The described process is an example of a regulated medical...

 Open the catalog to page 4
Medical Waste Autoclaves-5

Medical Waste Autoclaves Waste Treatment Sterilization The waste is sterilized by autoclaving using steam at high pressure and temperature (134ºC). This ensures that the biologically harmful elements of the waste are destroyed. Shredding ensures that any sharp elements of the waste are broken down, making them safe for handling and disposal. Another advantage of shredding is that it reduces the treated waste’s volume. After sterilization and shredding the waste is fragmented and non-toxic. It is safe for disposal in a municipal landfill. Compacting is an optional stage that significantly reduces...

 Open the catalog to page 5
Medical Waste Autoclaves-6

Advanced Control System for Your CSSD Sophisticated Touch Screen HMI Take advantage of Tuttnauer’s sophisticated user-friendly control systems for repeatable high performance. Choose either Tuttnauer’s sophisticated Bacsoft controller or the Allen-Bradley (AB 1400 PLC) controller. The HMI (Human Machine Interface) has been designed with the following considerations: • Multi-color display for easier reading from a distance Standard Features • 7” Multi-color touch screen panel • Keypad control panel on second door of two door autoclaves with Bacsoft controller • Stores the last 200 cycles in built-in...

 Open the catalog to page 6
Medical Waste Autoclaves-7

Medical Waste Autoclaves R.PC.R Software Automatic Recording of Cycle Information to Your PC Reporting You Can Rely On • Automatic recording of cycle information to any PC on your network • Convenient access to graphs and tables that are easy to understand • Easily generate PDF reports • No need to file printouts, saving you time Documentation Package An optional full documentation package is available: • Installation Qualification (IQ) • Operation Qualification (OQ) • Performance Qualification (PQ) Be in Control with Real-Time Remote Monitoring • See the real-time autoclave display on your PC...

 Open the catalog to page 7
Medical Waste Autoclaves-8

Large Autoclave Series Chamber volume between 250 and 1300 liters The Medical Waste Autoclave Line is designed to service hospitals and large medical centers that need to process high volumes of medical waste safely and on site. Features • Automatic or manual loading system • Manual or automatic door system • Pre-vacuum air stream sterilization • Optional advanced control system with touch screen control • HEPA air filter

 Open the catalog to page 8
Medical Waste Autoclaves-9

Medical Waste Autoclaves Autoclave Safety Door Safety • Chamber door cannot be opened when chamber is pressurized • Steam cannot enter the chamber when the door is open • A cycle cannot start if the door is open or not properly locked • Sliding door movement is stopped if an object is detected in front of the door Volume (Liter) Emergency Shut-Off Easily accessible emergency switches for immediate cycle shut-off. Double Independent Monitoring Digital and mechanical monitoring systems provide accurate pressure results which are displayed on the analog and digital displays. Safety Valves Both chamber...

 Open the catalog to page 9
Medical Waste Autoclaves-10

Economic Medium Size Autoclave Chamber volume of 160 liters The Biohazard Economic Line is ideal for most medical centers that need hospital grade medical waste treatment without large costly autoclaves. Designed to be economical high performance hard working autoclaves that offer substantial loading capacity and mobility in one easy to connect device. Features • Chamber volume of 160 liters with minimal foot-print • High volume water-ring vacuum-pump for fast and efficient air removal • Stand-by heating mode keeps the autoclave warm and ready for use • 316L grade stainless steel chamber and...

 Open the catalog to page 10
Medical Waste Autoclaves-11

Medical Waste Autoclaves Bulk Autoclave Series Chamber volume between 1500 and 4000 liters The medical waste bulk autoclave line is designed for high volume waste treatment. The autoclaves have pre and post vacuum capabilities. A wide range of sizes and upgrades are available to meet the ever-growing demands of medical waste facilities. Features • Optional advanced control system with touch screen control • Automatic or manual loading systems • Manual or automatic door systems • Pre-vacuum air stream sterilization • Printer for a clear and concise documentation of the sterilization process •...

 Open the catalog to page 11

Archived catalogs

  1. Elara 9D

    8  Pages

  2. Elara 9i

    8  Pages

  3. M and MK

    12  Pages

  4. 2540MKA

    12  Pages

  5. Nova

    12  Pages

  6. Elara

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.