Plasma Low Temperature Sterilization
12Pages

{{requestButtons}}

Catalog excerpts

Plasma Low Temperature Sterilization - 1

Plasma Low Temperature Sterilization With vaporized hydrogen peroxide Your Sterilization & Infection Control Partners v*/

Open the catalog to page 1
Plasma Low Temperature Sterilization - 2

Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization solution for heat & moisture sensitive equipment in CSSDs and Gastroenterology & Respiratory Endoscopy Clinics. With PlazMax you get increased productivity, reduced risk of work stoppage, and efficient supply of sterilized equipment where it’s needed. In operating rooms PlazMax benefits you with almost immediate access to sterilized equipment. Simple to install and control, only requiring 1-phase electricity and Hydrogen Peroxide (H2O2) packs to operate. No need...

Open the catalog to page 2
Plasma Low Temperature Sterilization - 3

PlazMax Line Advanced and Flexible Control System Take Advantage of Tuttnauer’s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features. 25 minutes Fast and Productive PlazMax cycle times are as low as 25 minutes (P50 normal cycle). Wide Range of Chambers Don’t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 4 models with chamber sizes from 47 to 162 liters. Keep Running Costs Low Keep you consumable costs low With PlazMax you have the freedom to use commonly available...

Open the catalog to page 3
Plasma Low Temperature Sterilization - 4

Chamber Door options Single | Double | Manual | Vertical Automatic with Hands-Free door operation Chamber Door options Single | Double | Manual | Vertical Automatic with Hands-Free door operation

Open the catalog to page 4
Plasma Low Temperature Sterilization - 5

PlazMax Line Single | Double | Manual | Vertical Automatic with Hands-Free door operation Technical Specifications Chamber Volume External Dimensions (WxHxD/D 2-doors) mm * Internal Chamber dimensions for each model are specified next to the image for each chamber 5

Open the catalog to page 5
Plasma Low Temperature Sterilization - 6

Advanced Control System for Your CSSD Take advantage of Tuttnauer’s sophisticated user-friendly control system for repeatable high performance. Standard Features • 7” Multi-color touch screen panel (also on second door of two door configurations) • Stores the last 200 cycles in built-in memory • Multiple access levels and user passwords to control access/ operation of the Plazmax • Diagnostic In/Out test (enables technician to check each system component separately) • Sterilization Temperature range 50°C to 55°C • Thermal Printer • USB and Ethernet connection port Sophisticated Touch Screen...

Open the catalog to page 6
Plasma Low Temperature Sterilization - 7

PlazMax Line R.PC.R Software Automatic Recording of Cycle Information to Your PC Reporting You Can Rely On • Automatic recording of cycle information to any PC on your network • Convenient access to graphs and tables that are easy to understand • Easily generate PDF reports • No need to file printouts, saving you time Be in Control with Real-Time Remote Monitoring • See the real-time autoclave display on your PC • Monitor all activity for up to 8 sterilizers With R.PC.R you can see: Graphs of the cycle data, Numeric cycle data, cycle print-outs, measured values table, parameter table....

Open the catalog to page 7
Plasma Low Temperature Sterilization - 8

Sterilization Cycle Process from Chamber Removal & Plasma " Plasma breaks down Hydrogen Peroxide (H?o;) molecules into Water (H^O) and Oxygen (02) outside the chamber Sterilization Cycle and Test Programs * Endoscope cycle temperature: short heating time and reduced H202 exposure time. Note: Cycle times are based on a hot cycle and may vary according to load volume.

Open the catalog to page 8
Plasma Low Temperature Sterilization - 9

PlazMax Line How can you be sure your hollow instruments have been 100% penetrated? Use Tuttnauer’s Process Challenge Device (PCD) Tuttnauer’s PCD kit includes lumens that are more difficult to penetrate than your loads. With the PCD you can be certain your lumen loads, like endoscopes, are fully exposed to the vaporized hydrogen peroxide sterilizing agent. The PCD kit includes long lumen configurations that cannot be successfully sterilized in many competing devices. The PCD Kit includes 1mm diameter lumens with lengths of 4m (both sides open) and 1.4m lumens (one side open). 4m both sides...

Open the catalog to page 9
Plasma Low Temperature Sterilization - 10

Non-Hollow Loads Non-hollow loads are sterilized with the “Normal Cycle”. Electrocautery Instruments Laser probe Ophthalmic lenses Defibrillator paddles Harmonic cable Hollow Loads Hollow loads are sterilized with the “Advanced Cycle”. Laryngscope blade Shaver hand pieces Surgical power drill Laryngscope & blades Fiber optic light cable • The instruments and equipment presented are only a partial list of the wide range that can be safely sterilized in PlazMax • Only use PlazMax with equipment authorized by original manufacturer to be sterilized with plasma steril

Open the catalog to page 10
Plasma Low Temperature Sterilization - 11

Endoscopes and similar equipment are sterilized with the "Endoscope Cycle' Rigid scope for optics Rigid scope Flexible endoscope I Flexible endoscope

Open the catalog to page 11
Plasma Low Temperature Sterilization - 12

Standards and Directives PlazMax has been developed according to the following international standards and directives (partial list): • ISO 9001:2008 • ISO 13485:2003 • ISO 14937 • EN 61010-2-040:2005 • EN 60601-1:2006/AC:2010 • Medical Device Directive 93/42/EC • CE Medical Device Mark 0344 Your Sterilization & Infection Control Partners Company Profile For over 90 years, Tuttnauer’s sterilization and infection control products have been trusted by hospitals, universities, research institutes, clinics and laboratories throughout the world. Supplying a range of top-quality products to over...

Open the catalog to page 12