1. Catalogs
  2. Tuttnauer
  3. Vertical & Benchtop Autoclaves

Vertical & Benchtop Autoclaves

Vertical & Benchtop Autoclaves
1 / 16 PagesView full catalog

Vertical & Benchtop Autoclaves

Product catalog summary
Overview
Tuttnauer provides a variety of advanced autoclaves for life sciences laboratories, suitable for applications such as liquid, pipette, glass, instrument, biohazard, and waste sterilization, as well as agar preparation. These autoclaves are equipped with sophisticated control systems and cater to research institutes, universities, and industries like medical, pharmaceutical, biotechnology, food, and chemical sectors.
Specifications
The autoclaves come in models with chamber volumes from 28 to 160 liters, constructed with 316L or 316Ti stainless steel. They feature a multi-color control panel and are available in vertical top-loading and benchtop front-loading designs, accommodating various flask sizes.
Features
- Multi-color display for cycle monitoring
- Advanced control system with Fo software and PID pressure control
- Memory storage for the last 200 cycles
- Compliance with 21 CFR part 11
- Optional fast cooling technology
- Efficient air removal and active drying options
Optional Features
- Built-in steam generator
- Vacuum pump for pre and post-vacuum cycles
- Biohazard air filter
- Customizable program cycles
Documentation and Reporting
An optional documentation package includes IQ, OQ, and PQ. The autoclaves support remote PC reporting and real-time monitoring, facilitating automatic cycle recording and PDF report generation.
Applications
Suitable for sterilizing liquids, solids, and biohazard materials, with specialized cycles for media processing and customizable tests like material stress and ageing tests.
Standards and Compliance
ASME certified and compliant with international standards such as DIN 58951-2:2003, PED 97/23/EC, RoHS, and safety standards like EN 61010-1:2010 and EN 61326-1:2006.
Safety Features
Includes safety devices to prevent door opening under pressure, cycle initiation only when the door is locked, and temperature sensors to prevent over-boiling and explosions.
Quality System Compliance
Complies with ISO 9001:2008, EN ISO 13485:2012, Canadian MDR, and FDA QSR 21 CFR parts 820 & 11.
Contact Information
For international sales and marketing, contact Tuttnauer Europe b.v. in the Netherlands or Tuttnauer USA Co. in New York.
See more

Catalog excerpts

Vertical & Benchtop Autoclaves-1

Vertical 8r Benchtop Autoclaves Your Sterilization & Infection Control Partners

 Open the catalog to page 1
Vertical & Benchtop Autoclaves-2

Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide high quality repeatable performance and accountability for a wide range of applications used in modern laboratories, which include: • Liquid sterilization (using two flexible PT100 probes) with various cooling options • Pipette and Glass sterilization • Instrument sterilization (wrapped or unwrapped) • Biohazard and Waste sterilization • Agar preparation • Specialized customized cycles For life science applications the Tuttnauer line of vertical and benchtop autoclaves...

 Open the catalog to page 2
Vertical & Benchtop Autoclaves-3

Vertical & Benchtop Autoclaves The laboratory autoclave line is designed for laboratory applications used in research institutes, universities, medical, pharmaceutical, biotechnology, food and chemical industries. Each model has a number of optional added-value features which can be configured for fast cooling, efficient drying, biohazard and waste sterilization, Fo control, and more. Benchtop lab autoclaves are designed to save space on your laboratory workbench. Vertical lab autoclaves are designed for your convenience and ease of use when vertically loading the autoclave. For over 90 years...

 Open the catalog to page 3
Vertical & Benchtop Autoclaves-4

Vertical Autoclaves - ELV Tuttnauer vertical laboratory autoclaves are top loading autoclaves available in chamber sizes from 31 to 160 liters. ELV models have an advanced multi-color control panel and a chamber made of 316L or 316Ti stainless steel. Erlenmeyer Flasks (ml) Loading Capacity Vertical D-Line Models - Technical Data Chamber Volume (Liter) 31 External Dimensions WxHxD (mm) 540 x 980 x 440 Schott-Duran Flasks (ml) Loading Capacity Model * External dimensions may change when an optional internal steam generator is added. Please see page 12.

 Open the catalog to page 4
Vertical & Benchtop Autoclaves-5

Vertical & Benchtop Autoclaves Benchtop Autoclaves Tuttnauer benchtop laboratory autoclaves are front loading autoclaves available in chamber sizes from 28 to 160 liters. EL models have an advanced multi-color control panel and a chamber made of 316L or 316Ti stainless steel. Erlenmeyer Flasks (ml) Loading Capacity Benchtop D-Line Models - Technical Data Chamber Volume (Liter) External Dimensions WxHxD (mm) Schott-Duran Flasks (ml) Loading Capacity Model * External dimensions may change when an optional internal steam generator is added * Optional shelves are needed to accommodate some of the...

 Open the catalog to page 5
Vertical & Benchtop Autoclaves-6

Advanced Control System for Your Laboratory Take Advantage of Tuttnauer’s state-of-the-art Control System with Multi-Color Display Features • Fo software control • PID (Proportional Integral Differential) pressure control • Stores the last 200 cycles in built-in memory • Two independent flexible PT100 temperature sensors to prevent over-boiling of liquids and explosions of bottles • Up to 6 temperature sensors and 4 pressure sensors can be connected • 30 Identification Codes and Passwords for access level control • The controller and software comply with the 21 CFR part 11 standard Innovative...

 Open the catalog to page 6
Vertical & Benchtop Autoclaves-7

Vertical & Benchtop Autoclaves Digital Cycle Data on Your PC Save cycle data files on your PC with no additional software or specialized hardware Select “Export History” Connect USB memory to your PC Create reports with R.PC.R View cycle data files on your PC R.PC.R Software Automatic Recording of Cycle Information to Your PC Reporting You Can Rely On • Remote PC Reporting (optional PC software) • Automatic recording of cycle information to any PC on your network • Convenient access to graphs and tables that are easy to understand • Easily generate PDF reports • No need to file printouts, saving...

 Open the catalog to page 7
Vertical & Benchtop Autoclaves-8

Liquid Loads Liquid Load Fast Cooling Applications Sterilizing liquid requires longer heating and cooling times for completing a cycle, especially with sensitive liquid loads. When time is critical, advanced optional fast cooling features are available with Tuttnauer’s laboratory autoclaves that prevent a sudden drop in chamber pressure which can cause liquids to boil over. Fast Cooling Graph Fast Liquid Cooling After sterilization is completed, compressed air is passed through a microbiological filter into the autoclave chamber in order to prevent a drop in pressure which also prevents load...

 Open the catalog to page 8
Vertical & Benchtop Autoclaves-9

Vertical & Benchtop Autoclaves Super Fast Liquid Cooling In addition to fast cooling, an optional fan can be applied to further circulate the compressed air in the chamber. This speeds up the heat exchange during the cooling stage in order to safely achieve super fast cooling of the liquid load under pressure. Tuttnauer’s accelerated fast liquid cooling technology reduces cycle time by as much as 90% and minimizes load exposure to high temperatures. Benchtop ELC Models Fan circulates air that speeds-up cooling Compressed Air Inlet Chamber is Pressurized Cold Water Inlet Chamber Temperature is...

 Open the catalog to page 9
Vertical & Benchtop Autoclaves-10

Glassware, Hollow and Tip Applications Efficient air removal is an important requirement for sterilizing hollow loads such as laboratory glassware and tips where the standard gravity displacement air removal method is not effective. Air removal after sterilization also assists in fast drying of your laboratory glassware. Active Drying with Post Vacuum An optional vacuum pump can be used for fractioned pre vacuum air removal eliminating air pockets from all load types and maximizing efficient steam penetration throughout the entire load. For benchtop autoclaves, an optional vacuum pump can be...

 Open the catalog to page 10
Vertical & Benchtop Autoclaves-11

Vertical & Benchtop Autoclaves For Applications that Need High Performance Tuttnauer's high performance laboratory autoclaves are equipped with the following optional features: a built-in steam generator, a vacuum pump and a coiled pipe around the chamber. These autoclaves provide efficient heat-up and complete drying. Fast and Efficient Heat-up Complete Drying Immediate Steam and Efficient Air Removal During the heat-up phase air is efficiently removed from the chamber by a strong vacuum pump. Steam, that is immediately available from the built-in steam generator, is then injected into the autoclave...

 Open the catalog to page 11

Archived catalogs

  1. Elara 9D

    8  Pages

  2. Elara 9i

    8  Pages

  3. M and MK

    12  Pages

  4. 2540MKA

    12  Pages

  5. Nova

    12  Pages

  6. Elara

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.