1. Catalogs
  2. UFIT IMPLANT
  3. dental implant system

dental implant system
1 /54Pages

dental implant system

dental implant system
1 /54Pages

Catalog excerpts

dental implant system-4

Established 2001. Ufit Implant is a dental implant manufacturer and distributor with all the staff working hard in unison to provide the best product and the excellent service to dentists and patients all over the world. With continued research and effort by the best techinical researchers in Korea that started in 2001 to provide a world class product, the Sylbutment was developed and launched in 2010. With Ufit Implant continuous research, the solution for loosening of joined fixture and abutment was presented according to clinical studies. We are consistently researching for innovative technologies...

 Open the catalog to page 4
dental implant system-5

The Ufit Dental Implant History 2001 JULY Established T.STRONG 2004 MAR Acquired Patent Registration for Torque Wrench Driver Adapter 2004 MAY Acquired Patent Registration for Dental Locking Abutment 2007 SEP Acquired Certification from KOREA GOOD MANUFACTURING PRACTICE 2011 JUL Received First Certified ISO 13485 License 2012 JAN Received Domestic Patent for SYLBUTMENT 2012 MAR Attend PHARMED & HEALTHCARE VIETNAM 2013 JUL Received Japan Patent for SYLBUTMENT 2015 JAN Ufit Exclusive Distributors in Kazakhstan 2015 FEB Received China Patent for Sylbutment 2021 MAR Ufit Implant is slected to pitch...

 Open the catalog to page 5
dental implant system-7

A revolution in dental implant systems SYLBUTMENT is the product of engineering research in which the perfect contact of two flat surfaces is only possible theoretically but practically impossible. Unprecedented - a remarkable sealing effect The Sealing Effect occurs because of elastic modification done by the pressure on the circular bands of the contact sides. Outstanding durability due to even stress distribution The even contact surfaces uniformly transfer power from prosthetic appliances to fixtures. Results of fatigue tests showed that not a single fatigue failure occurred when repeated...

 Open the catalog to page 7
dental implant system-8

The principles of The principles of SYLBUTMENT are easily discovered around us. Tire treads Sealing effect of a piston ring Conventional Abutment and In a conventional abutment, the gap between fixture and abutment may increase gradually due to repeated chewing forces. This is due to the contact between the outer surface of the abutment and the inner taper of the fixture, which only occurs on a small surface area due to the roughness of both the two surfaces. On the other hand, SYLBUTMENT increases the contact surfaces by transformation to the grooves. It does not create a gap as the transformation...

 Open the catalog to page 8
dental implant system-9

Research presentation in development of new sealing type abutment (SYLBUTMENT) for the improvement of contact state of abutment and fixture region Why does loosening occur in conventional abutments? The perfect contact of two flat surfaces is only possible theoretically but practically impossible. Repetitive chewing forces The Perfect Contact of Two Flat The theoretically possible perfect contact of two surfaces The actual contact of two surfaces The perfect contact of two flat surfaces is only possible theoretically but practically impossible. When a chewing force is applied then removed, the...

 Open the catalog to page 9
dental implant system-10

When the abutment screw is fastened, elastic deformation occurs around the grooves of the SYLBUTMENT, creating a force which moves the abutment and fixture together. Before fastening After fasteningthe Abutment Screw the Abutment Screw TM As shown in the figure above, chewing forces are experienced asymmetrically due to the grooves of the SYLBUTMENT acting as an elastic body. This firmly maintains the sealed state of the abutment and distributes the chewing forces evenly in the fixture. receiving chewing forces 10

 Open the catalog to page 10
dental implant system-11

Pressure distribution at the contact surfaces of the Fixtures and the Abutments (FEM Analysis) When conventional abutments experience asymmetrical chewing forces, the contact surfaces of the fixtures and abutments are separated; however, when a SYLBUTMENT is used, the contact surfaces are not separated. Conventional Abutment Fatigue Limit Load (Newton) Load (Newton) Conventional Abutments can withstand 5 million repeated loads of 344N~34N, but the SYLBUTMENT can withstand 5 million repeated loads of 552N~55N. Fatigue Limit Conventional Abutment

 Open the catalog to page 11
dental implant system-12

Micro Thread 2.5 Hex indentation and 11 degree Morse Taper. The deep 0.2 mm micro thread increases the surface area and induces a smooth connection with the larger main thread. Additionally, the micro thread increases thread contact with bone thereby improving the initial fixation effect. Dual Thread As 0.8mm pitch of dual thread type, the surgery time is reduced. (1.6mm per 1 rotation) Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media. Main Thread When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture...

 Open the catalog to page 12
dental implant system-13

Dual Thread 2.5 Hex fastening Type of 11 degree Morse Taper Type As 0.8 Dual Thread Type, the placing speed is very fast. (1.6mm per 1 rotation) Surface areas are increased through blasting by highly biocompatible Calcium-Phosphate Media. Main Thread When the fixture is inserted into the implant bed, the conical shape and lower deep thread of the fixture increase stability and make immediate loading possible. Cutting Edge When placing the implants, the cutting edge of the Twist Type increases Self Tapping ability and minimizes Bone resistance. Apex As a structure of D (Diameter) - 0.7mm, the...

 Open the catalog to page 13
dental implant system-14

Submerged System Flow Chart Solid impression coping Solid abutment Cover screw Healing abutment

 Open the catalog to page 14
dental implant system-15

Submerged System Flow Chart Abutment screw Transfer abutment Angled abutment Milling abutment Temporary abutment UCLA abutment Plastic cylinder Impression coping (Pick-up) Impression coping (Transfer) Cover screw Healing abutment

 Open the catalog to page 15
dental implant system-16

* Use mini size abutment • Mini Regular

 Open the catalog to page 16
dental implant system-17

* Use mini size abutment • Mini Regular € Wide

 Open the catalog to page 17
dental implant system-18

Cover screw Height 0.5 2 mini MICS 5005 MICS 5020 Cover screw Height 0.5 2 Use 1.2 Hex hand driver 5~8Ncm Joining torque Used to prevent foreign materials from entering after the fixture insertion • Mini Regular fl Wide

 Open the catalog to page 18
dental implant system-19

Healing abutment[m]n7^^^^^^^^^^^^^^| GH Height 3 Height 4 Height 5 Height 7 Use 1.2 Hex hand driver 5~8Ncm of joining torque Used to protect the connecting part of the implant Acts as the shape of the gingiva after surgery Abutment is chosen according to the patien's gingival height.

 Open the catalog to page 19