Catalog excerpts
biopsy valves & irrigation accessories
Open the catalog to page 1BioShield® biopsy valves and irrigation accessories are single-use, offering unsurpassed protection for patients and staff. Why single-use valves? It is nearly impossible to manually clean, disinfect, flush and dry biopsy valves. Reused biopsy valves can become leaky and potentially harbor dangerous pathogens - putting both patients and healthcare workers at risk. Fortunately, BioShield® biopsy valves are single-use, leaving you one less thing to worry about. Why take the risk? Trust BioShield® biopsy valves.
Open the catalog to page 2BioShield® biopsy valve It just makes sense Single-use valves reduce the possibility of cross-contamination between patients. Small valve size and easy device passage offer exceptional functionality during usage. convenience and peace of mind
Open the catalog to page 3Did you know? Findings suggest biopsy valves aren’t designed to be cleaned and reprocessed… FACT: The design of a biopsy valve inhibits the reach and effectiveness of cleaning brush bristles, making it nearly impossible to remove debris from inner crevices FACT: Biopsy valves have internal flaps that squeegee biomaterial off devices as they are extracted, allowing it to collect deep within the valve’s inner crevices Arrows show insufficient contact of cleaning brush bristles within internal crevices Play it safe...US Endoscopy’s line of BioShield® biopsy valves are single-use so you no...
Open the catalog to page 4In a documented study,* published in EndoNurse and Infection Control Today, researchers found visible debris/proteinaceous material in over 50% of the test valves. The reprocessed valves used in the study, supplied from three major U.S. institutions, were deemed “clean and ready to use” prior to microscopic evaluation. The results showed wear and damage to valve structure, gross contamination on the outer edges, and contamination within the nooks and crannies of the valves where cleaning brushes can’t always reach. (Figure 1.2-1.4 taken from David M. Parente, BS, BA, MBA, “Could Biopsy Port...
Open the catalog to page 5BioShield® irrigator... Flush blood, exudate and other debris out of your way at anytime throughout a procedure*- even with a device in place 1133 How important is a clear view? The BioShield® irrigator affords immediate, direct, intraprocedural irrigation. Simply attach a 60cc syringe to the irrigation line, or use extension tubing to connect with your water pump for hands-free, foot pedal control. Add a whole new level of efficiency to your endoscopy procedures with the BioShield® irrigator immediate, direct irrigation with device in channel *In order to achieve moderate irrigation...
Open the catalog to page 6product information part number Olympus & Fujinon (G5 series and newer) compatible 00711124* 00711125 00711128 00711135 biopsy biopsy biopsy biopsy valve valve valve valve (individually packaged) (20 per pack/10 packages) sterile (individually packaged) (individually packaged) biopsy valve (individually packaged) biopsy valve (20 per pack/10 packages) Pentax compatible biopsy valve (individually packaged) biopsy valve (individually packaged) universal irrigation accessories universal irrigating adaptor universal water pump extension tubing *Not currently for sale in the United States
Open the catalog to page 7Listening…and delivering solutions®, the US Endoscopy listening…and delivering solutions design, and all marks denoted with ® or ™ are registered with the U.S. Patent and Trademark Office, or trademarks owned by US Endoscopy BioShield® biopsy valves are intended to be used with gastrointestinal endoscopes. Fujinon® is a registered trademark of Fuji Film Co., Ltd. Olympus® is a registered trademark of Olympus Optical, Inc. PENTAX® is a registered trademark of Asahi Kogaku Kogyo Kabushiki Kaisha. phone fax customer service
Open the catalog to page 8All US endoscopy catalogs and technical brochures
-
VIA® procedure kits
8 Pages
-
New and Featured Products
12 Pages
-
Hemostasis Solutions
16 Pages
-
GI Procedure Products
16 Pages
-
Bite Blocks
4 Pages
-
Polypectomy Solutions
8 Pages
-
bioGuard
2 Pages
-
E-Z-Guard™
2 Pages
-
CO2EFFICIENT
2 Pages
-
Infinity®
2 Pages
-
Polypectomy
1 Pages
-
Histolock™ resection kit
2 Pages
-
Take-Out transport pad
2 Pages
-
BioShield irrigating adaptor
8 Pages
-
iSnare ® system
2 Pages
-
EndoRings device
2 Pages
-
Raptor ® grasping device
2 Pages
-
Guardus ® overtube
2 Pages
-
Entrada colonic overtube
2 Pages
-
Exacto cold snare
2 Pages
-
eTrap polyp trap
2 Pages
-
InStream polyp trap
2 Pages
-
Infinity cytology device
2 Pages
-
Talon grasping device
2 Pages
-
Raptor grasping device
2 Pages
-
Mio medical device organizer
2 Pages
-
Keeper device clip
2 Pages
-
Boost head positioner
2 Pages
-
Reach overtube
2 Pages
-
AdvanCE delivery device
2 Pages
-
Articulator injection needle
2 Pages
-
Carr-Locke injection needle
2 Pages
-
Vari-Safe injection needle
4 Pages
-
Velocity irrigation system
2 Pages
-
Torrent irrigation tubing
2 Pages
-
BioVac direct suction device
2 Pages
-
Feeding
8 Pages
-
Roth Net ® retriever
8 Pages
-
endoscope care and cleaning
12 Pages