Technical Specifications:
  • Heater: Single element CE approved ceramic heater with manual output control from 0 to 100%.
  • Phototherapy Unit: Provides irradiance of 6 - 8 µW/cm²/nm at bed level.
  • Electrical Safety: Complies with IEC 60601-1-2 standards for medical equipment.
  • Resuscitator: Features include airway ventilation outlet, oxygen flow rate control (0 to 6 liters/min), breathing rate control, and adjustable airway pressure (10 - 35 mm water column).
  • Suction Control: Maximum suction of 200 mm of Hg with a vacuum gauge range of 0 - 760 mm of Hg.
  • Auxiliary Oxygen Outlet: Oxygen flow control from 1 to 15 liters/minute with a maximum airway pressure of 55 cm water column.
Environmental and Physical Specifications:
  • Operating Temperature Range: 20°C to 33°C.
  • Storage Temperature Range: -25°C to 60°C.
  • Operating Humidity Range: 0 - 100% RH.
  • Physical Dimensions: Mattress dimensions are 780 mm in length, 490 mm in width, and 50 mm in thickness. The working level from the ground is 920 mm.
Features and Functionality:
  • Electronic Controller: Micro computerized system with large displays and feather touch keys for easy operation. Includes alarms for probe failure and temperature deviations.
  • Thermal Care: Uses a 750 W ceramic heater with a parabolic reflector for efficient heat distribution.
  • Apgar Timer: Digital timer with acoustic alarms at 1, 5, 10, 15, and 20 minutes post-birth.
  • Patient Bed: Adjustable to Trendelenburg and Fowler positions with acrylic sidewalls.
  • Observation Lamp: Halogen-based for focused lighting.
  • Optional Features: Includes resuscitator, electrical slow suction, phototherapy unit, and digital weighing scale.
Manufacturer Information:

V-Care Medical Systems Pvt Ltd, located at #30/2, S.V.Complex, Magadi Main Road, Vijayanagar, Bangalore, Karnataka, India. Contact: +91-80-2311 0651 / 52, Email: [email protected], Website: www.vcaremed.com

See more

Catalog excerpts

V-1000-1

RESUSCITATION UNIT : "V-1000" TECHNICAL SPECIFICATIONS V-Care TM all the way every way PHYSICAL PARAMETERS : HEATER : Mattress : 780 mm Length : 490 mm Width : 50 mm Thickness : 920 mm Working level from ground o Maximum baby tray tilt on : +/-8 both sides continuously variable : 130 kg Weight Castors : 100 mm with 2 brake wheels and 2 non - brake wheels Single element CE approved ceramic heater placed in a parabolic reflector. RESUSCITATION CENTRE "V-1000" Heater output control range in manual mode : 0 to 100 % } PHOTOTHERAPY UNIT : Supply to each tamp Irradiance ENVIRONMENTAL SPECIFICATIONS : o Operating temperature range Storage temperature range Operating Humidity range : 12 V, 50 W : 6 - 8 µW/cm2/nm at bed level RESUSCITATOR : o : 20 C to 33 C o o : -25 C to 60 C : 0 - 100% RH Airway ventilation outlet Oxygen flow rate control Breathing rate control Maximum airway pressure Adjustable airway pressuer Air pressure airway gauge Note : Best results obtained in low convective environmental : 0 to 6 liter/min : Manual : 40 cm water column : 10 - 35 mm water column : 0-60 cm water column ISO 9001:2000 ISO 13485:2003 CMDCAS ELECTRICAL SPECIFICATIONS : Electrical Supply SUCTION CONTROL : : 230V ± 10% 50Hz, 6A Power consumption with Heater at max. output Power consumption with Heater, Photo therapy and observation lamp ON Maximum suction Vacuum gauge range } : 750W } : 200 mm of Hg : 0 - 760 mm of Hg : 1250 W AUXILIARY OXYGEN OUTLET : Oxygen flow control Maximum airway pressure OBSERVATION LIGHT : Power required : 1 - 15 liter/minute : 55 cm water column : 12 V, 50 W ELECTRICAL SAFETY : ELECTRONICS : As per IEC 60601-1-2 for medical equipments Micro computerized system SKIN TEMPERATURE PROBE : Range Accuracy Resolution Probe interchangeability o o : 28 C to 38 C o : +/-0.2 C within range o : 0.1 C o : +/- 0.2 C (Servo) NOTE : DUE TO OUR CONTINUOUS R&D PROGRAM THE SPECIFICATIONS AND DESIGN MAY CHANGE WITHOUT PRIOR NOTICE. Manufacturer : V V-Care Medical Systems Pvt Ltd, # 30 / 2, S.V.Complex, Magadi Main Road, Vijayanagar, Bangalore - 560 040. KARNATAKA, INDIA Ph:+91-80-2311 0651 / 52, Fax:+91-80-2311 0645 Mobile: +91-98440 78793 E-mail: [email protected], [email protected], [email protected] Website: www.vcaremed.com We believe that a warmer design should take into account both the science and art of the thermal regulation. To provide the most efficient use of heat we select the appropriate wattage, use the best material for heating element and design the reflectors for maximum effectiveness. The art involves designing the unit for optimum functionality. It is an equation we have worked hard to perfect.

 Open the catalog to page 1
V-1000-2

NEONATAL RESUSCITATION CENTRE : “V-1000” NEONATAL RESUSCITATION CENTRE : “V-1000” Neonatal resuscitation units are commonly used as open care incubator in the delivery rooms, Intensive care units & operation theaters. They must combine heat control, Resuscitation, Phototherapy unit, space for monitoring systems and complete accessibility to the infant with an optimum medical procedural capability. THE ELECTRONIC CONTROLLER : ! The controller is based on micro computerized system. ! Large bright displays are easy to monitor & for viewing from a distance. ! Double digital display system provided...

 Open the catalog to page 2

Archived catalogs

  1. STP-DS

    2  Pages

  2. V-150

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.