1. Catalogs
  2. Vacu Activ
  3. Activ Aqua Bed

Activ Aqua Bed
1 /30Pages

Activ Aqua Bed

Activ Aqua Bed
1 /30Pages

Catalog excerpts

Activ Aqua Bed-1

Activ Aqua Bed Manual guide

 Open the catalog to page 1
Activ Aqua Bed-2

MetricsProducer VACU ACTIV World Leading Manufacturer tosino, ul. Modrzewiowa 1 76-251 Kobylnica POLAND Customer service / Technical service (ordering spare parts for machine components): Copyright 2023 Vacu Activ +48 501 186 938 www.vacuactiv.com TECHNICAL SUPPORT www.vacuactiv.com/technical-support/

 Open the catalog to page 2
Activ Aqua Bed-3

Table of Contents 1. Safety & Warning 1.2 Transport and installation of the appliance 3. Electrical specifications of the appliance 5. Filling the appliance with water and draining it 6.1 Starting the oxygen generator 6.2 Connecting the oxygen generator to the hydromassage 6.3 Connecting with Bluetooth 6.5 Adjusting the oxygen delivery rate 7.2 Switching the water heating on and off 7.3 Setting water temperature 7.4.1 Setting patient height 7.4.3 Selecting body parts 7.4.4 Setting the appliance's runtime TECHNICAL SUPPORT Copyright 2023 Vacu Activ

 Open the catalog to page 3
Activ Aqua Bed-4

1. Safety & Warnings In order to maintain safe use of the appliance, please read the following operating instructions and follow the guidelines contained therein. Operator - a person who has been trained in the use of the appliance. The operator is responsible for the correct operation of the appliance and for observing the necessary service intervals for individual parts. User/patient - a person who uses a hydro massage bed. He or she is not responsible for the correct function of the appliance or for its maintenance. Electrician - a person with the appropriate professional training, knowledge,...

 Open the catalog to page 4
Activ Aqua Bed-5

1.2 Transport and installation of the appliance The appliance can be transported on a recyclable pallet. The appliance is delivered and transported by a qualified technician or by the dealer in your region or country. The operator is responsible for supplying power to the appliance in accordance with the requirements and regulations applicable to the country or region. The appliance shall not be installed outdoors. Indoors, the ambient temperature should oscillate between -15 and +60 degrees Celsius. The tank should be vented during filling or two days after the tank has been filled to its capacity....

 Open the catalog to page 5
Activ Aqua Bed-6

Copyright 2023 Vacu Activ TECHNICAL SUPPORT www.vacuactiv.com/technical-support/

 Open the catalog to page 6
Activ Aqua Bed-7

4. Connecting a touchscreen To connect the operating screen, unpack the cardboard box containing the screen. Next, mount the screen in the mounting bracket. The next step involves connecting the monitor's power supply and the communication port. It's important to connect the communication port to a connector labelled "USB" and not "Serial port". Incorrect connection will result in faulty operation of the appliance. Once the screen is correctly connected, an application will be launched on the screen and the device will initiate the synchronisation process if it was previously filled with water....

 Open the catalog to page 7
Activ Aqua Bed-8

The appliance is filled via the plumbing system. Filling is achieved with the filling valve. The water level is determined by an inductive sensor mounted on the appliance housing. When the level is suitable, the touchscreen displays a message. This must be approved. The appliance details are shown below. To fill the appliance with water, turn the side pieces of the appliance. There is a V2 filling valve at the top. The connected hose must be of the same diameter as the valve and no section of it should be kinked or bent. Upon connecting the water hose from the water mains, turn the drain valve...

 Open the catalog to page 8
Activ Aqua Bed-9

Loosen the oxygen therapy cover. To do this, use an Allen key. STEP 2 Loosen the screws securing the housing to the appliance frame. Copyright 2023 Vacu Activ TECHNICAL SUPPORT

 Open the catalog to page 9
Activ Aqua Bed-10

Loosen the fixing screws from the front of the appliance. Use an Allen key. STEP 4 Carefully lift the appliance housing and pull it away from the frame. Disconnect the LED supply connectors and the communication leads for the touchscreen. Copyright 2023 Vacu Activ TECHNICAL SUPPORT www.vacuadiv.com/technical-support/

 Open the catalog to page 10
Activ Aqua Bed-11

STEP 5 Remove the black cover and turn the vent plug. Once it is loosened, press the valve stem and turn it by 90 degrees in a gentle motion. TECHNICAL SUPPORT Copyright 2023 Vacu Activ

 Open the catalog to page 11
Activ Aqua Bed-12

Connect the water hose to the drain valve. Make sure that the hose is properly connected and that it is not kinked or kinked anywhere. Fill the massage bed until the display indicates that the water level is high enough to start the appliance. When the water level is appropriate, the appliance controller will initiate the synchronisation procedure. CAUTION The water should be changed at least once a month when the appliance is in use. Add glycol or other agents that prevent the build-up of scale and algae, which can damage the appliance, to the water. The use demineralised water is acceptable....

 Open the catalog to page 12
Activ Aqua Bed-13

6. Oxygen generator During massage, the oxygen generator is meant to improve the comfort of the massager and facilitate the recovery of the human body. The generator is a separate appliance supplied with the massage bed. "Hie appliance includes a Bluetooth function so that you can listen to your favourite music during the massage. Furthermore, the generator has LED RGBW lights, which are controlled via the control panel. Before starting the oxygen generator, check that the fuse is in the on position, i.e. the switch is in the down position. As shown in the picture below. Then plug the power plug...

 Open the catalog to page 13
Activ Aqua Bed-14

The generator should be connected to a 230 V AC power supply to any power socket. The cable coming from the top cover should be connected to the socket on the back of the generator. Note the positioning pin so that it is in the position shown in the picture below. Then push the connector all the way in. 6.3 Connecting with Bluetooth The generator can be connected to a phone via Bluetooth so that you can listen to music during the massage. To do this, launch Bluetooth on your phone, then search for the appliance and pair it with your phone. The icon on the generator's dashboard will flash. Once...

 Open the catalog to page 14
Activ Aqua Bed-15

6.4 Controlling the LED light The generator has the LED light function, which can be operated with a button on the dashboard. To change the colour of the light, press the button on the dashboard. Each press of the button will change the colour. To turn off the LED light, press the button until the LED switches off. 6.5 Adjusting the oxygen delivery rate Blowing power is adjusted by turning the right-hand dial. Turning it to the left will increase the flow of oxygen, while turning it to the right will decrease the flow. TECHNICAL SUPPORT Copyright 2023 Vacu Activ

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.