Group: BRAND
Catalog excerpts
ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE
Open the catalog to page 1ATEX chemistry diaphragm pumps. ATEX VARIO® chemistry diaphragm pumps. Chemistry diaphragm pumps, vacuum systems and gauges for use in areas with potentially explosive atmospheres When intended for use in areas with potentially explosive atmospheres, European Community Directive 94/9/EC (ATEX) requires equipment in conformity with ATEX standards. VACUUBRAND offers Category 2 chemistry diaphragm pumps and vacuum systems in conformity with ATEX (for use in zones where an explosive atmosphere is likely to occur). These chemistry diaphragm pumps are appropriate for such locations because they...
Open the catalog to page 22.3 ATEX vacuum pumps // www.vacuubrand.com/atex
Open the catalog to page 3Pumping speed diagram at 50 Hz, without gas ballast NOW AVAILABLE WITH VARIO®-CONTROL A characteristic feature of all models is their high performance even close to specified ultimate vacuum. The pumps are also characterized by excellent long-term stability of performance.
Open the catalog to page 4O outstanding chemical resistance and tolerance to condensate by use of fluoro plastics Q flame-proof motor with built-in and self-retaining overcurrent and excess temperature protection, the customer does not need any additional overcurrent protection system Q overpressure safety relief valve at the outlet Q safety diaphragm design with inert gas purge feature to permit optional installation of a diaphragm crack-detection system Q separator AK and emission condenser EK for pump protection and solvent recovery Technical data ATEX conformity Pumping chamber (pumped gases): II 2G IIC T3X...
Open the catalog to page 5O outstanding chemical resistance and tolerance to condensate by use of fluoro plastics flame-proof motor with built-in and self-retaining overcurrent and excess temperature protection, the customer does not need any additional overcurrent protection system overpressure safety relief valve internal and at the outlet safety diaphragm design with inert gas purge feature to permit optional installation of a diaphragm crack-detection system separator AK and emission condenser EK for pump protection and solvent recovery Technical data ATEX conformity Pumping chamber (pumped gases): II 2G IIC...
Open the catalog to page 6MV 10C EX MV 10C EX +AK +EK O outstanding chemical resistance and tolerance to condensate by use of fluoro plastics Q flame-proof motor with built-in and self-retaining overcurrent and excess temperature protection, the customer does not need any additional overcurrent protection system Q overpressure safety relief valve internal and at the outlet Q safety diaphragm design with inert gas purge feature to permit optional installation of a diaphragm crack-detection system Q separator AK and emission condenser EK for pump protection and solvent recovery Technical data ATEX conformity Pumping...
Open the catalog to page 7O full advantage of ATEX chemistry diaphragm pumps O short process times due to hysteresis-free VARIO® vacuum control VARIO®-pump operates on demand only as fast as necessary - minimal power consumption, extended maintenance intervals, silent operation vacuum controller CVC 3000 (optional) for precise vacuum control and fully automatic processes complete system accessories I/O-Module, supply / isolation amplifier and ATEX vacuum sensor Technical data ATEX conformity Pumping chamber (pumped gases): II 2G IIC T3X Environment with inert purge gas: II 2G IIB T4 X Environment without inert...
Open the catalog to page 8O full advantage of ATEX chemistry diaphragm pumps O short process times due to hysteresis-free VARIO® vacuum control O VA^O®-pump operates on demand only as fast as necessary - minimal power consumption, extended maintenance intervals, silent operation O vacuum controller CVC 3000 (optional) for precise vacuum control and fully automatic processes O complete system accessories I/O-Module, supply / isolation amplifier and ATEX vacuum sensor Technical data ATEX conformity Pumping chamber (pumped gases): II 2G IIC T3X Environment with inert purge gas: II 2G IIB T4 X Environment without...
Open the catalog to page 9^ cvc 3000 Installation outside of the EX-area, without integrated sensor Control range (dependent on the sensor) 1080 - 0.1 mbar / 810 - 0.1 torr Interface external RS 232C Interface to pump / sensor Analog-I/O-Module, connectable via isolation amplifier ordering data i) CVC 3000, 100-230 V ~50-60 Hz Supply / isolation amplifier 4 ATEX-sensor
Open the catalog to page 10O large analog and digital vacuum display O mains independent power supply unit BVE 9V, with ATEX approval, mercury and cadmium free O enhanced battery life due to automatic shutdown and variable sampling rate O high reliability, low EMI emission level near detection limit, high degree of immunity to electromagnetic interference for use in industrial environments O capacitive alumina ceramic diaphragm vacuum sensor with excellent chemical resistance, accuracy and long term stability Vacuum Gauge ATEX category 2 approval Technical data ATEX-approval II 2G Ex ia IIC T4 Upper measuring...
Open the catalog to page 11Phone Fax Sales Service 995541 PRINTED IN GERMANY EN / 06 / 2015 © VACUUBRAND GMBH + CO KG
Open the catalog to page 12All Vacuubrand catalogs and technical brochures
-
Connection Guide
22 Pages
-
VACUU·SELECT®, Vacuum Controller
16 Pages
-
DVR 3pro, Vacuum Gauge
2 Pages
-
ATEX VACUUM PUMPS AND GAUGES
12 Pages
-
CHEMISTRY DIAPHRAGM PUMPS
12 Pages
-
DVR 2pro
2 Pages
-
VACUU·VIEW
4 Pages
-
Chemistry Compatibility
2 Pages
-
CVC 3000 detect
2 Pages
-
BVC Accessories
2 Pages
-
Catalog 2014/2015
191 Pages