3024M-1

X-RAY PRODUCTS Digital Image Receptor Product Descrip on The PaxScan 3024M is a X-ray flat panel detector designed for full-field digital mammography (FFDM) systems. The 3024M is available with Gigabit Ethernet interface. Technical Specifications Receptor Type . . . . . . . . . . . . . . . . . . . . . . Amorphous Silicon Technology Conversion Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CsI Pixel Area Total . . . . . . . . . . . 29.7 (h) x 23.4 (v) cm (11.7 x 9.2 inch) Active . . . . . . . . . . 29.7 (h) x 23.2 (v) cm (11.7 x 9.1 inch) Pixel Matrix Total . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,584 (h) x 2,816 (v) Active . . . . . . . . . . . . . . . . . . . . . . . . . . 3,584 (h) x 2,792 (v) Pixel Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 mm2 Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 lp/mm Energy Range Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 - 40 kVp Fill Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~70% Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive A/D Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-bit Software The software release includes ViVA™, a basic application for image acquisition and viewing on an end-user workstation or laptop running Microsoft® Windows™. The developer’s software package includes a “Virtual Command Processor” software interface that performs detector calibration, detector set-up, image acquisition, and image corrections. ViVA™ includes file type translators for .viv, .raw, .jpg, and .bmp file formats. Windows® XP compatible. Environmental Shock Tolerance . . . . . . . . . . . . . . . 20G (any direction no power applied) Temperature Range - Operating (at back cover) . . . 10°C to 35°C (max.) (Ambient) Storage . . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C Humidity - Operating (non-condensing) . . . . . . . . . . . . . . . . . . . 10 to 90% Storage (non-condensing) . . . . . . . . . . . . . . . . . . . . 10 to 90% Regulatory U.S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 61010-1 Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CSA 22.2 No. 601.1-M90 Frame Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 fps (1 x 1) Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gigabit Ethernet Exposure Control . . . . . . . . . . . . . . . . . . . . . . . . . . Inputs: Expose-Request Outputs: Expose-OK Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Sensor Protection Material . . . . . . . . . . Carbon fiber plate and aluminum Power Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <30 watts (cont.) 45 watts (max.) PaxScan is a Registered Trademark of Varian Medical Systems Manufactured by Varian Medical Systems

 Open the catalog to page 1
3024M-2

X-RAY PRODUCTS PaxScan 3024MDigital Image Receptor Dimensions are for reference only Dimensions are in mm [inches] NOTE: As with all Varian Amorphous Silicon Image Receptors, the PaxScan 3024M is designed to be integrated into a complete X-ray system by a qualified system integrator. The system integrator is responsible for obtaining FDA clearance for medical use. var/an medical systems 1678 South Pioneer Road Salt Lake City, Utah 84104 Phone: 801-972-5000 Fax: 801-973-5050 Varian Proprietary & Confidential Information. Use is prohibited without Varian’s express written consent. Copyright © 2015,...

 Open the catalog to page 2

All VAREX Imaging catalogs and technical brochures

  1. 4336W

    2  Pages

  2. 4336X

    4  Pages

  3. 2530W

    4  Pages

Archived catalogs

  1. 4343CB

    2  Pages

  2. GS-3074

    8  Pages

  3. MCS-6074

    8  Pages

  4. 2530C

    2  Pages

  5. Linatron K15

    2  Pages

  6. B-130HM

    6  Pages

  7. B-135H

    6  Pages

  8. B-130H

    6  Pages

  9. B-121

    6  Pages

  10. B-115

    6  Pages

  11. B-110

    6  Pages

  12. B-112

    6  Pages

  13. B-100

    6  Pages

  14. B-147

    6  Pages

  15. B-148H

    6  Pages

  16. B-146H

    6  Pages

  17. B-146HM

    6  Pages

  18. B-145W

    6  Pages

  19. B-145A

    6  Pages

  20. B-185H

    6  Pages

  21. B-180H

    6  Pages

  22. B-165H

    6  Pages

  23. 4343R ver3

    2  Pages

  24. 4336R

    2  Pages

  25. AMX4

    4  Pages

  26. OPTICA™ 40

    2  Pages

  27. Linatron® M3

    4  Pages

  28. GS-2079

    8  Pages

  29. GS-2077

    8  Pages

  30. GS-1584

    8  Pages

  31. GS-1587

    8  Pages

  32. Nexus DRF

    2  Pages

  33. Nexus DR

    2  Pages

  34. Attila

    2  Pages

  35. XRpad 4343 F

    2  Pages

  36. XRD 4343RF

    2  Pages

  37. XRpad2 4336

    2  Pages

  38. PaxScan 2020X

    2  Pages

  39. Nexus DR

    2  Pages

  40. Optica™ 30

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.