video corpo

4336R
2Pages

{{requestButtons}}

Catalog excerpts

4336R - 1

PaxScan® 4336R Flat Panel Detector Product Description The PaxScan 4336R is the first ruggedized portable X-ray flat panel detector designed formobile digital radiographic X-ray systems to fit existing 14"x17" standard bucky trays. Based upon the new Gigabit Ethernet interface, images are displayed on a usersupplied workstation. Technical Specifications Receptor Type . . . . . . . . . . . . . . . . . Amorphous Silicon Technology Pixel Matrix Total . . . . . . . . . . . . . . . . . . . . . . . 3,072 (v) x 2,560 (h) Active . . . . . . . . . . . . . . . . . . . . . . 3,052 (v) x 2,540 (h) The software release includes ViVA™, a basic application for image acquisition and viewing on an end-user workstation or laptop running Microsoft® Windows™. The developer’s software package includes a “Virtual Command Processor” software interface that performs detector calibration, detector set-up, image acquisition, and image corrections. ViVA™ includes file type translators for .viv, .raw, .jpg, and .bmp file formats. Windows® XP and Windows® 7 (32 bit) compatible. Computer Requirements Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 lp/mm Image Quality CPU . . . . . . . . Pentium dual core running @ 2.0 GHz or equivalent Conversion Screen . . . Direct Deposit CsI, Detached CsI, DRZ Plus Pixel Area Total . . . . . . . 42.7 (v) x 35.6 (h) cm (16.8 x 14.0 inch) Active . . . . . . 42.4 (v) x 35.3 (h) cm (16.7 x 13.9 inch) GADOX (typical) DD/CSI (typical) DQE @ 0 lp/mm DQE @ 1 lp/mm DQE @ 2 lp/mm DQE @ 3 lp/mm DQE @ Nyquist MTF @ 1 lp/mm MTF @ 2 lp/mm MTF @ 3 lp/mm MTF @ Nyquist Sensitivity Power Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 watts (cont.) 35 watts (max.) I/O Interface Box . . . . . . . . . . . . . . . . . . . . 100 - 240 VAC, 47 - 63 Hz (Up to 9m away from panel) Mechanical Weight (includes battery) . . . . . . . . . . . . . . . . . . . . . 8.6 lbs. (3.9 kg) Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Energy Range Sensor Protection Material . . . . Carbon fiber plate and aluminum Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gigabit Ethernet Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-shock tolerance Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX1 Water Resistant Cycle Time (minimum / standard) . . . . . . . . . . . . . . . . . . . 4 / 5 sec. Exposure Control Inputs: . . . . . . . . . . . . Prepare, Expose-Request Temperature Range - Operating (at back cover) 10°C to 35°C (max.) (Ambient) - Storage . . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C Outputs: . . . . . . . . . . . . . . . . . . . . . . . . Expose-OK Humidity - Operating & Storage (non-condensing) . . 10% to 90% Patient Contact Atmospheric Pressure - Operating & Storage . . 70 kPa to 106 kPa Weight Limit Uniform load across entire carbon fiber surface . . . . . . . 150 kg Concentrated 40mm diameter load at the center . . . . . . 100 kg Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN/CSA C22.2 No. 60601-1:08 EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC/EN 60601-1:2005 * Without enclosure ®PaxScan is a Registered Trademark of Varex Imaging Corporation 134772-000 Rev B 08/17 Copyright © 2017, Varex Imaging

Open the catalog to page 1
4336R - 2

PaxScan® 4336R Flat Panel Detector Dimensions are for reference only Dimensions are in mm [inches] 2 Denotes Approximate Center of Gravity 3 Active Area Dimension 4 Top Surface of Active Area 5 Hybrid Cable (Approximate Ø 9.5mm) Manufactured by Varex Imaging Corporation Specifications subject to change without notice. Salt Lake City, UT 1-801-972-5000 Charleston, SC 1-843-767-3005 www.vareximaging.com Note: All Varex Imaging Amorphous Silicon Receptors are designed to be integrated into a complete X-ray system by a qualified system integrator. The system Integrator is responsible for...

Open the catalog to page 2

All VAREX Imaging catalogs and technical brochures

  1. 4343R ver3

    2 Pages

  2. 4343CB

    2 Pages

  3. 4336X

    4 Pages

  4. 4336W

    4 Pages

  5. 4336W

    4 Pages

  6. 2530W

    4 Pages

  7. 2530C

    2 Pages

  8. Nexus DR

    2 Pages

  9. B-165H

    6 Pages

  10. B-180H

    6 Pages

  11. B-185H

    6 Pages

  12. B-145A

    6 Pages

  13. B-145W

    6 Pages

  14. B-146H

    6 Pages

  15. B-146HM

    6 Pages

  16. B-147

    6 Pages

  17. B-148H

    6 Pages

  18. B-100

    6 Pages

  19. B-110

    6 Pages

  20. B-112

    6 Pages

  21. B-115

    6 Pages

  22. B-121

    6 Pages

  23. B-130H

    6 Pages

  24. B-130HM

    6 Pages

  25. B-135H

    6 Pages

  26. AMX4

    4 Pages

  27. Optica™ 30

    2 Pages

  28. OPTICA™ 40

    2 Pages

  29. Linatron K15

    2 Pages

  30. MCS-6074

    8 Pages

  31. GS-3074

    8 Pages

  32. GS-2079

    8 Pages

  33. GS-2077

    8 Pages

  34. GS-1587

    8 Pages

  35. GS-1584

    8 Pages

  36. Nexus DRF

    2 Pages

  37. Nexus DR

    2 Pages

  38. Attila

    2 Pages

  39. 3024M

    2 Pages

  40. XRpad 4343 F

    2 Pages

  41. XRD 4343RF

    2 Pages

  42. XRpad2 4336

    2 Pages

Archived catalogs