Product catalog summary
Overview: The Linatron® M9 and M9A are modular high-energy X-ray sources designed by Varex Imaging Corporation. These systems are adaptable for mobile, gantry, and fixed installations, with a common control console, modulator, and RF unit across all models, while the X-ray head varies based on application.
1.0 Standard Equipment and Services:
  • Control Console: Features a touchscreen display.
  • X-ray Head: Low leakage of 0.1%.
  • Modulator/Power Distribution: Includes external signal interface.
  • Temperature Control Unit (TCU): Maintains components at 30°C, suitable for environments from -40°C to +55°C.
  • Spare Parts Kit: Contains over 40 items including PC boards.
  • Cables and Hoses: Interconnecting cables and hoses included, up to 100 meters.
  • Manuals: Operator manuals provided in English.
  • Installation Supervision: Includes radiographic optimization.
  • Warranty: Varex’s standard warranty applies.
2.0 Performance:
  • X-ray Beam Quality: Derived from broad beam data measurements.
  • Dose Rate: Maximum continuous dose rate at 1 meter is specified in Table 1.
  • Field Size: Defined by a 30° cone or 22.5° square.
  • Focal Spot Size: Does not exceed 2.0 mm in diameter.
  • Beam Symmetry: Asymmetry does not exceed 5% at ±7.5° off the central axis.
  • Leakage Radiation: Specified along the horizontal axis at 1 meter from the beam centerline.
3.0 Customer Facility Requirements:
  • Electrical Requirements: Operates from a single 15 kVA power source with low and high voltage options.
  • TCU Power Source: Requires a separate 13-kVA power source.
  • Operating Environment: Indoor temperature between 4°C and 35°C; outdoor range depends on TCU and insulation.
  • Ventilation: Heat output specified for each component.
4.0 Optional Equipment:
  • Custom Beam Collimation: Nonstandard field sizes and motorized collimator available.
  • Lower Leakage Options: Detailed in Table 3.
  • Voltage Regulator: Recommended for installations with power fluctuations.
  • Beam Flattener: Provides uniform beam intensity.
  • Dual Energy: Specifications provided in Table 4.
  • Laser Alignment System: Available for beam alignment.
  • Variable External Collimator: Field size varies between 1° and 24°.
  • Remote Customer Interface: Includes various signals for external equipment.
Quality and Compliance:
  • ISO 9001: Varex Imaging Corporation is ISO 9001 registered.
  • CE Marking: Models meet safety and EMC standards, complying with EU Directives.
  • Safety Standards: Complies with IEC/EN 61010-1:2010 and ANSI/UL/CSA standards.
  • EMC Standards: Complies with FCC and CISPR 11 standards.
  • EU Directives: Complies with Low Voltage, EMC, and RoHS Directives.
See more

Catalog excerpts

Linatron® M9 & M9A-1

The Linatron® M™ is a modular system. The control console, modulator, and RF unit are common to all model configurations. Only the X-ray head changes to match the application. The Linatron M is designed to fit mobile, gantry, and fixed installations. 1.0 Standard Equipment and Services 1.1 Control Console The standard control console is a touch screen display system. Touchscreen Control Console 1.2 X-ray Head Low Leakage (0.1%) 1.3 Modulator/Power Distribution Cabinet External signal interface. 1.4 Temperature Control Unit (TCU) The TCU is used to keep the system components at a nominal 30°C (86°F). It is available in high voltage and low voltage configurations for environments ranging from -40/+55°C (-40/131°F), condensing. 1.5 Standard Spare Parts Kit The standard spare parts kit includes over 40 items such as PC boards and individual components. 1.6 Interconnecting Cables (X-ray Head to Modulator. Modulator to Console) and Hoses (TCU to X-ray Head) Included. Lengths up to 100 meters. 1.7 Manuals Operator manuals are included in English. 1.8 Installation Supervision and Startup * Radiographic Optimization available. 1.9 Varex’s Standard Warranty The X-ray beam quality is derived from a compilation of broad beam data measurements. 2.2 X-ray Beam Dose Rate* (10 cm x 10 cm field). The maximum continuous dose rate at 1 meter is listed in Table 1 (without flattening filter). *Dose rate is reduced with flattening filter. 2.3 X-ray Field Size A 30° cone or 22.5° square defines the field. Also see section 4.1. 2.4 X-ray Beam Focal Spot Size The focal spot size does not exceed 2.0 mm in diameter. 2.5 X-ray Beam Symmetry The beam asymmetry does not exceed 5% at ±7.5° off the central axis for all energies. Copyright © 2017, Varex Imaging Corporation. All Rights Reserved.

 Open the catalog to page 1
Linatron® M9 & M9A-2

Linatron® M9 & M9AModular High-energy X-Ray Source 3.3.3 Ventilation 2.6 Standard Leakage Radiation The leakage radiation is specified along the horizontal axis at 1 meter from the beam centerline at angles 60° and greater, outside the primary beam. The values in Table 2 are a fraction of the primary beam central axis dose rate measured with a 10 cm x 10 cm collimator. Leakage is taken with the primary beam completely blocked. See section 4.2 for lower leakage options. 3.0 Customer Facility Requirements 3.1 Electrical Requirements The Linatron M operates from a single 15 kVA 50/60 Hz power source....

 Open the catalog to page 2
Linatron® M9 & M9A-3

4.5 Dual Energy For a complete description of these signals, request document #100015302. The dual energy specifications are given in Table 4. Select two operating energies: 4.10 Small Focal Spot An internally mounted single spot laser is available to align the X-ray beam to an object being radiographed. ULLP shielding option is unavailable with the laser option. Laser is 533 nm, Class II, 0.5 mW. Quality 4.6 Laser Alignment System 1.0 to 1.5 mm available * Maximum dose rate may be reduced. 4.9 Smart Remote Customer Interface The Linatron uses industry standard Modbus TCP Client/Server Protocol....

 Open the catalog to page 3
Linatron® M9 & M9A-4

Linatron® M9 & M9A Modular High-energy X-Ray Source Salt Lake City, UT Tel: 801-972-5000 Fax: 801-973-5050 Varex Imaging and Linatron are registered trademarks, and Linatron M is a trademark of Varex Imaging Corporation. All other trademarks are the property of their respective owners. Copyright © 2017, Varex Imaging Corporation. All Rights Reserved.

 Open the catalog to page 4

All VAREX Imaging catalogs and technical brochures

  1. 4336W

    2  Pages

  2. 4336X

    4  Pages

  3. 2530W

    4  Pages

Archived catalogs

  1. 4343CB

    2  Pages

  2. GS-3074

    8  Pages

  3. MCS-6074

    8  Pages

  4. 2530C

    2  Pages

  5. Linatron K15

    2  Pages

  6. B-130HM

    6  Pages

  7. B-135H

    6  Pages

  8. B-130H

    6  Pages

  9. B-121

    6  Pages

  10. B-115

    6  Pages

  11. B-110

    6  Pages

  12. B-112

    6  Pages

  13. B-100

    6  Pages

  14. B-147

    6  Pages

  15. B-148H

    6  Pages

  16. B-146H

    6  Pages

  17. B-146HM

    6  Pages

  18. B-145W

    6  Pages

  19. B-145A

    6  Pages

  20. B-185H

    6  Pages

  21. B-180H

    6  Pages

  22. B-165H

    6  Pages

  23. 4343R ver3

    2  Pages

  24. 4336R

    2  Pages

  25. AMX4

    4  Pages

  26. OPTICA™ 40

    2  Pages

  27. Linatron® M3

    4  Pages

  28. GS-2079

    8  Pages

  29. GS-2077

    8  Pages

  30. GS-1584

    8  Pages

  31. GS-1587

    8  Pages

  32. Nexus DRF

    2  Pages

  33. Nexus DR

    2  Pages

  34. Attila

    2  Pages

  35. 3024M

    2  Pages

  36. XRpad 4343 F

    2  Pages

  37. XRD 4343RF

    2  Pages

  38. XRpad2 4336

    2  Pages

  39. PaxScan 2020X

    2  Pages

  40. Nexus DR

    2  Pages

  41. Optica™ 30

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.