

Catalog excerpts

X-RAY PRODUCTS Digital Image Receptor PaxScan 1313DXT imagers provide industry leading CBCT and Panoramic image quality for mid-size dental applications. Varian's amorphous silicon based detectors are the gold standard for CBCT in medical, dental and industrial applications. Amorphous silicon brings key advantages unmatched by other technologies, including: - radiation hardness > 1MRad - widest input energy range - immunity from single photon events in the substrate - excellent low dose performance - proven 3-D soft-tissue capability Varian's extensive dental product line allows the OEM to easily integrate multiple panel sizes. The Virtual CP software interface is common across all the panels and the entire product line is offered with Gigabit Ethernet. Technical Specifications Receptor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amorphous Silicon Conversion Screen . . . . . . . . . . . . . . . . . . Direct Deposit CsI, DRZ Plus The software release includes ViVA™, a basic application for image acquisition and viewing on an end-user workstation running Microsoft® Windows™. The developer’s software package includes a “Virtual Command Processor” software interface that performs detector calibration, detector set-up, image acquisition, and image corrections. ViVA™ includes file type translators for .viv, .raw, .jpg, and .bmp file formats. Pixel Area Pixel Matrix Total . . . . . . . . . . . . . . . . . . . . . . . . 1024 x 1024 (1 x 1) 512 x 512 (2 x 2) Active Pixel Matrix for CsI . . . . . . . . . . . . . . . . . 1014 x 1014 (1 x 1) 508 x 508 (2 x 2) Pixel Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 μm2 Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.94 lp/mm MTF, X-Ray . . . . . . . . . . . . . . . >48% @ 1 lp/mm (1 x 1), CsI screen Energy Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 - 160 kVp Fill Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57% Environmental Temperature Range - Operating . . . . . . . . . . . . . . . 10°C to 35°C (max.) (Ambient) - Storage . . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C Humidity - Operating (non-condensing) . . . . . . . . . . . . . . . . . 10 to 90% Storage (non-condensing) . . . . . . . . . . . . . . . . . . . 10 to 90% Atmospheric Pressure - Operating . . . . . . . . . . . . . . . 70 kPa to 106 kPa Storage . . . . . . . . . . . . . . . . . 70 kPa to 106 kPa Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive Frame Rate (Workstation dependent) . . . . . . . . . . . . . . 30 fps (1 x 1) 60 fps (2 x 2) Image Capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pleora Gigabit Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gigabit Ethernet Exposure Control . . . . . . . Opto Coupled, External Sync, Expose OK Sensor Protection Material Carbon fiber plate (2.5 mm thick) and aluminum Power Power Dissipation . . . . . . . . . . 11 Watts nominal power consumption) 11 to 35V input range, 15 V typical ®PaxScan is a Registered Trademarks of Varian Medical Systems Manufactured by Varian Medical Systems, Inc. Specifications subject to chang
Open the catalog to page 1
medical systems NOTE: As with all Varian Amorphous Silicon Image Receptors, the PaxScan into a complete X-ray system by a quali- fied system integrator. The system inte- grator is responsible for obtaining FDA Varian Medical Systems 1678 South Pioneer Road Salt Lake City, Utah 84104 Copyright © 2012, Varian Medical Systems, Inc. All Rights Reserved.
Open the catalog to page 2All VAREX Imaging catalogs and technical brochures
-
4336W
2 Pages
-
4343CB
2 Pages
-
4336X
4 Pages
-
2530W
4 Pages
-
2530C
2 Pages
-
B-165H
6 Pages
-
B-180H
6 Pages
-
B-185H
6 Pages
-
B-145A
6 Pages
-
B-145W
6 Pages
-
B-146H
6 Pages
-
B-146HM
6 Pages
-
B-147
6 Pages
-
B-148H
6 Pages
-
B-100
6 Pages
-
B-110
6 Pages
-
B-112
6 Pages
-
B-115
6 Pages
-
B-121
6 Pages
-
B-130H
6 Pages
-
B-130HM
6 Pages
-
B-135H
6 Pages
-
Linatron K15
2 Pages
-
PaxScan® 4030X
2 Pages
-
PaxScan® 4030CB
2 Pages
-
PaxScan® 3030X
2 Pages
-
PaxScan® 3030DX
2 Pages
-
MCS-6074
8 Pages
-
GS-3074
8 Pages
Archived catalogs
-
4343R ver3
2 Pages
-
4336R
2 Pages
-
Nexus DR
2 Pages
-
AMX4
4 Pages
-
Optica™ 30
2 Pages
-
OPTICA™ 40
2 Pages
-
LINATRON™ XP
2 Pages
-
Linatron® M6 & M6A
4 Pages
-
Linatron® M9 & M9A
4 Pages
-
Linatron® M3
4 Pages
-
GS-2079
8 Pages
-
GS-2077
8 Pages
-
GS-1587
8 Pages
-
GS-1584
8 Pages
-
Harmony Series
4 Pages
-
CBCT Software Tools
2 Pages
-
Nexus DRF
2 Pages
-
Nexus DR
2 Pages
-
Attila
2 Pages
-
3024M
2 Pages
-
XRpad 4343 F
2 Pages
-
PaxScan® 2530DX
2 Pages
-
XRD 4343RF
2 Pages
-
XRpad2 4336
2 Pages
-
Security Detectors
4 Pages
-
PaxScan 2520DX
2 Pages
-
PaxScan 2121DXV
2 Pages
-
PaxScan 2020X
2 Pages
-
PaxScan 2020DXV
2 Pages
-
PaxScan 1515DXT
2 Pages
-
PaxScan 1508 DXT
2 Pages
-
PaxScan 1313DX
2 Pages
-
PaxScan 1308DXT
2 Pages
-
PaxScan 1308DX
2 Pages