Catalog excerpts

X-RAY PRODUCTS Digital Image Receptor Product Description The PaxScan® 2020X is a real-time digital X-ray imaging device commonly referred to as a flat panel detector (FPD). The main system components are the 20 x 20cm 194μm-pixel amorphous silicon FPD and Command Processor CP2LC. Excellent low-dose performance is achieved by combining Varian’s proprietary readout electronics with a custom Cesium Iodide scintillator. A Windows® based application program and a communications command (DLL) library has also been developed to assist OEM customers tasked with developing their own system interface. This imager is intended for incorporation into a complete X-ray system by a qualified equipment manufacturer. Technical Specifications Receptor Type . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amorphous Silicon Conversion Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integral columnar CsI:TI Pixel Area - Total . . . . . . . . . . . . . . . . . . 199 mm (h) x 199 mm (v) (7.8 x 7.8 in.) Pixel Matrix - Total . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,024 (h) x 1,024 (v) Effective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,004 (h) x 1,004 (v) Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.58 lp/mm @ 30 fps (1 x 1) 1.29 lp/mm @ 60 fps (2 x 2) Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... Parallel Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fiber optic Manufactured by Varian Medical Systems Specifications subject to chang
Open the catalog to page 1
X-RAY PRODUCTS Digital Image Receptor Drawing for reference only Inches [Centimeter] NOTE: As with all Varian Amorphous Silicon Image Receptors, the PaxScan 2020X is designed to be integrated into a complete X-ray system by a qualified system integrator. The system integrator is responsible for obtaining FDA clearance for medical use. 1678 South Pioneer Road Salt Lake City, Utah 84104 Phone: 801-972-5000 Fax: 801-973-5050 Varian Proprietary & Confidential Information. Use is prohibited without Varian’s express written consent. Copyright © 2016, Varian Medical Systems. All Rights Reserved
Open the catalog to page 2All VAREX Imaging catalogs and technical brochures
-
4336W
2 Pages
-
4343CB
2 Pages
-
4336X
4 Pages
-
2530W
4 Pages
-
2530C
2 Pages
-
B-165H
6 Pages
-
B-180H
6 Pages
-
B-185H
6 Pages
-
B-145A
6 Pages
-
B-145W
6 Pages
-
B-146H
6 Pages
-
B-146HM
6 Pages
-
B-147
6 Pages
-
B-148H
6 Pages
-
B-100
6 Pages
-
B-110
6 Pages
-
B-112
6 Pages
-
B-115
6 Pages
-
B-121
6 Pages
-
B-130H
6 Pages
-
B-130HM
6 Pages
-
B-135H
6 Pages
-
Linatron K15
2 Pages
-
PaxScan® 4030X
2 Pages
-
PaxScan® 4030CB
2 Pages
-
PaxScan® 3030X
2 Pages
-
PaxScan® 3030DX
2 Pages
-
MCS-6074
8 Pages
-
GS-3074
8 Pages
Archived catalogs
-
4343R ver3
2 Pages
-
4336R
2 Pages
-
Nexus DR
2 Pages
-
AMX4
4 Pages
-
Optica™ 30
2 Pages
-
OPTICA™ 40
2 Pages
-
LINATRON™ XP
2 Pages
-
Linatron® M6 & M6A
4 Pages
-
Linatron® M9 & M9A
4 Pages
-
Linatron® M3
4 Pages
-
GS-2079
8 Pages
-
GS-2077
8 Pages
-
GS-1587
8 Pages
-
GS-1584
8 Pages
-
Harmony Series
4 Pages
-
CBCT Software Tools
2 Pages
-
Nexus DRF
2 Pages
-
Nexus DR
2 Pages
-
Attila
2 Pages
-
3024M
2 Pages
-
XRpad 4343 F
2 Pages
-
PaxScan® 2530DX
2 Pages
-
XRD 4343RF
2 Pages
-
XRpad2 4336
2 Pages
-
Security Detectors
4 Pages
-
PaxScan 2520DX
2 Pages
-
PaxScan 2121DXV
2 Pages
-
PaxScan 2020DXV
2 Pages
-
PaxScan 1515DXT
2 Pages
-
PaxScan 1508 DXT
2 Pages
-
PaxScan 1313DXT
2 Pages
-
PaxScan 1313DX
2 Pages
-
PaxScan 1308DXT
2 Pages
-
PaxScan 1308DX
2 Pages