VARIAN BRACHYTHERAPY INFORM PLAN VERIFY TREAT BrachyVision Treatment Planning medical systems
Open the catalog to page 1Expect more with BrachyVision The new paradigm for image-based planning BrachyVision™ is a complete 3D treatment planning system that introduces a new paradigm of patient-centric, image-based planning. Optimized for use with Varian’s VariSource™ iX and GammaMedplus™ iX HDR afterloader products, BrachyVision meets all of your brachytherapy planning needs. As part of the ARIA™ oncology information system family, BrachyVision oers a common interface for users of Varian systems. BrachyVision oers: • Integration with the Eclipse™ treatment planning system supporting a combined database, patient registration,...
Open the catalog to page 2Complete brachytherapy planning system BrachyVision is a complete treatment planning system that allows plans to be generated for LDR, PDR, and HDR treatments using coordinates, lms, or 3D images. Image acquisition Ideally suited for accelerated prostate brachytherapy Combined with the advanced capabilities of BrachyVision, Vitesse™ real-time HDR brachytherapy allows 3D HDR prostate brachytherapy to be performed accurately and quickly without the need for CT. The exibility of BrachyVision allows the user to acquire images • Using DICOM 3.0 • Directly from an ARIA server Image registration The...
Open the catalog to page 3Extensive set of tools to meet every need Powerful contour editing Delineate target volumes Plan data from localization radiographs For image-guided brachytherapy (IGBT), segmenting organs at risk and precisely delineating target volumes are critical and time-consuming tasks. BrachyVision uses the same extensive set of tools found in Eclipse to reduce this time from hours to minutes. Clinicians can accurately dene target and critical structures on fused multi-modality images with advanced drawing and editing capabilities. Enhanced templates and powerful post-processing of structures accelerate...
Open the catalog to page 4Planning with the latest technology Multiple dose optimization methods BrachyVision provides a variety of dose optimization methods which may be used alone or in combination to obtain the optimal dose plan. Adaptive volume optimization (AVOL) Manual dose optimization Dose Shaper™ graphical interactive optimization provides inverse visual planning Adaptive volumetric optimization introduces options to the existing inverse planning tool to get the plan you want — the rst time, every time. The optimization routine attempts to match the specied DVH limits to structures (or lines) while creating smoother...
Open the catalog to page 5Intuitive plan evaluation Analyze and compare alternative plans Technical specications Use the plan evaluation workspace for analyzing and comparing alternative plans to determine the most appropriate plan for treatment. Compare plans side by side, or sum and evaluate matched image sets. View DVHs on the same graph for both multiple and summed plans. Stand alone workstations Software • HDR brachytherapy planning • DICOM-3 network image data interface Hardware (conguration to be as follows or better) Tower system • LDR brachytherapy planning • Template-based pre-plans BrachyVision creates an export...
Open the catalog to page 6Varian Medical Systems Oncology Systems 3100 Hansen Way Palo Alto, CA 94304-1038 Tel: 650.424.5700 | Tel: 800.544.4636 http://www.varian.com For more information on BrachyVision, visit http://www.varian.com/brachytherapy. USA Headquarters California Varian Medical Systems Palo Alto, CA Tel: 650.424.5700 800.544.4636 Fax: 650.493.5637 www.varian.com BrachyTherapy Offices USA Varian Medical Systems BrachyTherapy Head Office Charlottesville, VA Tel: 888.666.7847 Fax: 434.244.7181 UK Varian Medical Systems UK Ltd. BrachyTherapy Crawley, West Sussex, UK Tel: 44.1293.601.219 Fax: 44.1293.542.626 Germany...
Open the catalog to page 715 Pages
7 Pages
2 Pages
11 Pages
16 Pages
150 Pages
4 Pages
7 Pages
8 Pages
2 Pages
4 Pages
2 Pages
2 Pages
3 Pages
9 Pages
3 Pages
3 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
22 Pages
4 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
10 Pages
12 Pages
8 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
8 Pages
2 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
7 Pages
3 Pages
7 Pages
147 Pages