Catalog excerpts

The Varian SRS Package includes specifically-designed features that provide the clinician with confidence to deliver Stereotactic Radiosurgery (SRS). Additionally, the features help reduce overall time and resources required for SRS when compared to traditional methods. This can lead to an increase in the volume of procedures performed and lower per procedure costs for the hospital when compared to traditional surgery procedures. Frameless SRS may be administered using real-time tracking capabilities offered in the SRS package. Even slight motion has the potential to be assessed in real-time with the help of Varian’s optical technology and 3D mapping of the patient’s external surface – all while minimizing dose to healthy tissue. Stereotactic radiosurgery is growing as a technique New technology advances are expected to extend clinical applications, increase patient throughput and help reduce side effects.* Targeted treatment is driving radiotherapy growth. SRS treatment volume is expected to grow 93% from 2010 to 2020.** Growth Factors in SRS: • Mounting pressure to increase efficient equipment utilization that reduce treatment times • Use of fewer treatment sessions is preferred by both patients and clinicians • Decreases in overall costs • SRS delivers strong margins for oncology and neuroscience programs* *Source: Sg2 Intelligence, Technology Guide, EBRT Platforms, 2013 **Source: Sg2 Intelligence, Technology Guide, SRS/SBRT, 2013 FOR HEALTH PROFESSIONALS ONLY Package features: OPTICAL SURFACE MONITORING SYSTEM OSMS Start-Up Screen The Varian SRS Package uses non-ionizing real-time surface tracking to monitor patient motion after patient set up has been completed. Real time and accurate assessment of target location during beam delivery is combined with the instantaneous beam gating capability of Varian linacs. This combination can allow clinicians to reduce uncertainty margins, which is critical when delivering to a wide range of targets in the brain. • The system’s 3D imaging technology produces high resolution and accurate 3D surface data referenced to the treatment isocenter • The user has the ability to compare the treatment position with the reference surface both inside the treatment room and remotely • Highly accurate tracking of cranial position for all couch angles throughout treatments allowing non-coplanar treatments • A continuously updating display with a refresh rate optimized for tracking intracranial targets shows motion in all six degrees of freedom and may be viewed
Open the catalog to page 1
• Direct calibration to treatment beam isocenter • Seamless integration with beam gating for out-of-threshold patient or target motion • SRS Phantom for QA (matched to within +/-0.1 mm tolerance) and levelling plate SRS QA Phantom Table 1: Optical Surface Monitoring System (Select Specifications) 1 Leakage specified for 6X and 10X High Intensity energy configurations per IEC 60601-2-1, Leakage through Beam Limiting Devices 2 For additional IEC conical collimator leakage performance specifications for 6 MV and 10 MV, please refer to 100042130 TrueBeam®, TrueBeam® STx, and Edge™ IEC Type...
Open the catalog to page 2
ECLIPSE CONE PLANNING IMMOBILIZATION ACCESSORIES FROM QFIX™ Eclipse Cone Planning provides planning and dose calculation for treatments utilizing stereotactic cones. Immobilization accessories offered in the Varian SRS Intracranial Package have been specifically chosen to be used in a stereotactic treatment environment. Fibreplast™ Open View Mask Support for frame or frameless immobilization gives clinical staff the flexibility to choose the ideal treatment approach and continue to expand treatment techniques in their oncology program. These key features assist with planning stereotactic...
Open the catalog to page 3
The Head Support minimizing overstretching of the mask while simultaneously offering cranial support. • Quantity in package: 5 MOLDCARE® Cushion The MOLDCARE Cushion provides customized head support for enhanced patient comfort during positioning and treatment. The cushion is composed of a soft fabric bag containing expanded polystyrene beads coated in a moisture-cured resin. The pillow becomes rigid when activated with water and conforms to the contours of the patient's head and neck. With the Silverman Head Support, it creates the most comfortable and repeatable head support. • 20 cm x 35...
Open the catalog to page 4All Varian Oncology catalogs and technical brochures
-
Halcyon
15 Pages
-
Eclipse
7 Pages
-
TrueBeam Safety Features
2 Pages
-
TrueBeam Brochure
11 Pages
-
ProBeam Brochure
16 Pages
Archived catalogs
-
Brachytherapy Applicator Catalog
150 Pages
-
GammaMedplus™ iX Afterloader
4 Pages
-
Trilogy Brochure
7 Pages
-
VitalBeam
8 Pages
-
HyperArc Overview
2 Pages
-
Eclipse™
2 Pages
-
ProBeam 360
2 Pages
-
VELOCITY SOFTWARE
3 Pages
-
ProBeam Compact Brochure
9 Pages
-
oNCOLOGY CARE MANAGEMENT
3 Pages
-
360 ONCOLOGY
3 Pages
-
Proton Therapy reatment
4 Pages
-
HALCYON
12 Pages
-
PaxScan ® 3030X
2 Pages
-
PaxScan ® 4336X
4 Pages
-
PaxScan ® 4343R
2 Pages
-
Nexus-DRF™
2 Pages
-
2520DX
2 Pages
-
1515DXT
2 Pages
-
PaxScan 1508 DXT
2 Pages
-
PaxScan 1313DXT
2 Pages
-
1308DXT
2 Pages
-
Calypso Product Brief
2 Pages
-
Clinac Brochure
12 Pages
-
Capri? Applicator Set
2 Pages
-
Edge Brochure
22 Pages
-
NDI-452
4 Pages
-
M-101G
6 Pages
-
M-105SP
6 Pages
-
M-109
6 Pages
-
M-113
6 Pages
-
M-143
6 Pages
-
M-147SP
6 Pages
-
M-146
6 Pages
-
M-147
6 Pages
-
RAD-85S
6 Pages
-
M-149
6 Pages
-
M-151
10 Pages
-
M-152
12 Pages
-
M-153
8 Pages
-
PaxScan 3030+
2 Pages
-
M-171
6 Pages
-
PaxScan 2520E+
2 Pages
-
PaxScan 4030E
2 Pages
-
PaxScan 4336R
2 Pages
-
PaxScan® 2520XI/V
2 Pages
-
PaxScan® 2520D/CL
2 Pages
-
PaxScan® 2020X
2 Pages
-
PaxScan® 2020+
2 Pages
-
1313
2 Pages
-
PaxScan® 1308
2 Pages
-
Vitesse 3.0
3 Pages
-
BrachyVision
7 Pages
-
RapidArc
8 Pages
-
Varian Exact© IGRT couch
2 Pages
-
ARIA Oncology Information System
12 Pages
-
PaxScan ® 4030CB
2 Pages
-
PaxScan ® 1508DXT
2 Pages
-
PaxScan ® 1313DX
2 Pages
-
PaxScan ® 1308DX
2 Pages
-
Vitesse? 2.5
2 Pages
-
VariSeed? 8.0 Brochure
7 Pages
-
BrachyVision Acuros
3 Pages
-
BrachyVision? 8.5
7 Pages
-
Varian BrachyTherapy
147 Pages