NDI-452

NDI-452

NDI-452

Product catalog summary
X-Ray Tube Specifications
The NDI-452 X-Ray tube is designed for NDI and security applications, featuring a maximum peak voltage of 450 kV. The anode and cathode to ground voltages are both 225 kV. It includes a small focal spot of 2.5 mm and a large focal spot of 5.5 mm, with oil as the cooling medium. The maximum continuous rating is 900 W for the small focal spot and 4500 W for the large focal spot, both requiring a cooling flow of 14 liters per minute. The target material is tungsten with a target angle of 30° and radiation coverage of 90° x 10°.

Installation Instructions
Proper installation involves careful cleaning and greasing of the rubber cone and cable terminal. The mounting flange should be attached without rotating from its setup position. High voltage cables of type R28 are used for connection.

Operation Guidelines
The equipment manufacturer is responsible for controlling high voltage and filament current. Adequate cooling of the anode is crucial to prevent damage, requiring monitoring of flow, pressure, and temperature of the cooling medium. The cooling medium must continue for at least 2 minutes after switching off the tube.

Cooling and Insulation
The anode must be cooled with high voltage insulating oil with a dielectric strength of at least 20 kV/mm, free of air. Insufficient cooling can lead to anode destruction.

Additional Information
The product is manufactured by Varian Medical Systems, with specifications subject to change. The housing type is V-452, and the approximate weight is 95 kg (209.5 lbs).
See more

Catalog excerpts

NDI-452-1

X-RAY PRODUCTS Stationary Anode X-Ray Tube Product Description The NDI-452 is a 450 kV, oil cooled stationary anode metal ceramic x-ray source. This source is specifically designed for NDI and Security Applications. X-Ray Tube Specifications Maximum Peak Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 kV Anode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 kV Cathode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 kV Focal Spot - EN12543 Small . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = 2.5 mm Large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D = 5.5 mm Cooling Medium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Oil Maximum Continuous Rating Small . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 W with 14 Litre/min cooling flow Large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4500 W with 14 Litre/min cooling flow Target Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tungsten Target Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30° Reference Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perpendicular to port face. Radiation Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90° X 10° Loading Factors for Leakage Radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 kV, 10 mA Maximum Radiation Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mSv/h X-Ray Tube Assembly Permanent Filtration . . . . . . . . . . . . . . . . . . . . . 2.3 mm Fe + 1 mm Cu High Voltage Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R28 Housing Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-452 Weight (approx.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 kg (209.5 lbs) 21494 Rev B 03/07 Manufactured by Varian Medical Systems Specifications subject to change without notice.

 Open the catalog to page 1
NDI-452-2

X-RAY PRODUCTS Instructions for Installation and Operation Connection of the x-ray tube The careful adjustment of the pressure gap and the use of the correct amount of silicone grease are extremely important. First, clean the rubber cone carefully with a lint-free cloth. Take specific care that the contacts are absolutely free of old grease or oxide layers. Use only pure alcohol for cleaning, no other detergents. Cover the entire cone with a thin film of the supplied silicone grease, apply a rope of approximately 3 cm of grease and spread it gently, avoiding the contact tip. The grease layer...

 Open the catalog to page 2
NDI-452-3

medical systems Housing Outline Drawing MOUNTING BRACKET Copyright © 2007, Varian Medical Systems. All Rights Reserved.

 Open the catalog to page 3
NDI-452-4

medical systems Rating Charts medical systems Salt Lake City, UT 1-801-972-5000 Copyright © 2007, Varian Medical Systems. All Rights Reserved.

 Open the catalog to page 4

All Varian Oncology catalogs and technical brochures

  1. Halcyon

    15  Pages

  2. Eclipse

    7  Pages

Archived catalogs

  1. VitalBeam

    8  Pages

  2. Eclipse™

    2  Pages

  3. ProBeam 360

    2  Pages

  4. 360 ONCOLOGY

    3  Pages

  5. Nexus-DRF™

    2  Pages

  6. 2520DX

    2  Pages

  7. 1515DXT

    2  Pages

  8. 1308DXT

    2  Pages

  9. Clinac Brochure

    12  Pages

  10. Edge Brochure

    22  Pages

  11. M-101G

    6  Pages

  12. M-105SP

    6  Pages

  13. M-109

    6  Pages

  14. M-113

    6  Pages

  15. M-143

    6  Pages

  16. M-147SP

    6  Pages

  17. M-146

    6  Pages

  18. M-147

    6  Pages

  19. RAD-85S

    6  Pages

  20. M-149

    6  Pages

  21. M-151

    10  Pages

  22. M-152

    12  Pages

  23. M-153

    8  Pages

  24. PaxScan 3030+

    2  Pages

  25. M-171

    6  Pages

  26. PaxScan 4030E

    2  Pages

  27. PaxScan 4336R

    2  Pages

  28. 1313

    2  Pages

  29. Vitesse 3.0

    3  Pages

  30. BrachyVision

    7  Pages

  31. RapidArc

    8  Pages

  32. Vitesse? 2.5

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.