PaxScan ® 4030CB-1

X-RAY PRODUCTS Digital Image Receptor Product Description The PaxScan® 4030CB is specifically designed to meet the needs of Cone Beam X-ray imaging applications featuring multiple sensitivity ranges and extended dynamic range modes. The main system components are the 40 x 30cm 194µm-pixel amorphous silicon FPD and real-time image and Command Processor 2. Excellent low-dose performance is achieved by combining Varian’s proprietary readout electronics with the high sensitivity of a custom Cesium Iodide scintillator. A Windows®XP™ based application program and a communications command (DLL) library has also been developed to assist OEM customers tasked with developing their own system interface. This imager is intended for incorporation into a complete X-ray system by a qualified equipment manufacturer PaxScan® 4030CB Receptor and Command Processor 2. (Fiber optic cable not shown) Technical Specifications Receptor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amorphous Silicon Conversion Screen . . . . . . . . . . . . . . . . . . . . . . Integral columnar Csl:Tl Inactive Lines . . . . . . . . . . . . . . . . . . . . . . . . < 9 total rows and columns, minimum separation 16 lines Pixel Area - Total . . . . . . . . . . 397 mm (h) x 298 mm (v) (15.6 x 11.7 in) Pixel Matrix - Total . . . . . . . . . . . . . . . . . . . . . . . . 2,048 (h) x 1,536 (v) Pixel Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 µm Limiting Resolution . . . . . . . . . . . . . . . . . . . 2.58 lp/mm @ 7.5 fps (1x1) 1.29 lp/mm @ 30 fps (2x2) Inactive Pixels . . . . . . . . . . No inactive visible pixels after interpolation Maximum Entrance Dose/Frame Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Passive convection Lead Barrier Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optional Temperature Limit . . . . . . . . . . . . . . . . . . . . . 10 - 35°C case temperature Relative Humidity . . . . . . . . . . . . . . . . . . . . . . 10 - 90% Non-Condensing Fill Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70% Contrast Ratio . . . . . . . . . . . . . . . . . . . . . . Large Area (120 mm):< 0.8% Small Area (10 mm): < 7% Lag . . . . . . . . . . . . . . . . . . . . . <16% (first frame, 30 fps, 2x2 bin mode) <5% (first frame, 7.5 fps, 1x1 bin mode) Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive Atmospheric Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 kPa - 106 kPa Shock Tolerance . . . . . . . . . . . . . . 20G (any direction no power applied) Regulatory U.S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL 60601-1 Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-speed serial Spectral Response . . . . . . . . . . . . . . . . . . . . . 400-700 nm; 550 nm peak Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.9 kg panel only 20.8 kg panel with lead primary barrier. Signal Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 pC/pixel/frame Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Gamma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Radiation Tolerance . . . . . . 1MRad (active area), 10 kRad (electronics) Dynamic Range (saturation-to-noise) Dual/Dynamic Gain Modes . . . . . . . . . . . . . . . . . . . . 18,000 : 1 Full-Resolution Modes . . . . . . . . . . . . . . . . . . . . . . . . 3,000 : 1 Fluoro Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,500 : 1 Dual/Dynamic Gain Modes, Effective resolution . . . . . . . . . . >16-bits 2017 Rev B 02/12 Sensor Protection . . . . . . . . . . . . . . . Carbon fiber plate 2.5 mm thick plus 0.25 mm thick aluminum plate. Mounting Provisions . . Blind, threaded mounting holes front and back. ®PaxScan is a Registered Trademarks of Varian Medical Systems Manufactured by Varian Medical Systems Specifications subject to change without notice.

 Open the catalog to page 1
PaxScan ® 4030CB-2

medical systems Digital Image Receptor Front View Rear View medical systems Image Acquisition Modes (Current) Image Acquisition Modes (Digital Board 2.0 with Dynamic-Gain readout required) Dynamic Gain High Range: Additional Modes: Consult Varian Medical Systems, Inc. Salt Lake City, UT Copyright © 2012, Varian Medical Systems. All Rights Reserved.

 Open the catalog to page 2

All Varian Oncology catalogs and technical brochures

  1. Halcyon

    15  Pages

  2. Eclipse

    7  Pages

Archived catalogs

  1. VitalBeam

    8  Pages

  2. Eclipse™

    2  Pages

  3. ProBeam 360

    2  Pages

  4. 360 ONCOLOGY

    3  Pages

  5. Nexus-DRF™

    2  Pages

  6. 2520DX

    2  Pages

  7. 1515DXT

    2  Pages

  8. 1308DXT

    2  Pages

  9. Clinac Brochure

    12  Pages

  10. Edge Brochure

    22  Pages

  11. NDI-452

    4  Pages

  12. M-101G

    6  Pages

  13. M-105SP

    6  Pages

  14. M-109

    6  Pages

  15. M-113

    6  Pages

  16. M-143

    6  Pages

  17. M-147SP

    6  Pages

  18. M-146

    6  Pages

  19. M-147

    6  Pages

  20. RAD-85S

    6  Pages

  21. M-149

    6  Pages

  22. M-151

    10  Pages

  23. M-152

    12  Pages

  24. M-153

    8  Pages

  25. PaxScan 3030+

    2  Pages

  26. M-171

    6  Pages

  27. PaxScan 4030E

    2  Pages

  28. PaxScan 4336R

    2  Pages

  29. 1313

    2  Pages

  30. Vitesse 3.0

    3  Pages

  31. BrachyVision

    7  Pages

  32. RapidArc

    8  Pages

  33. Vitesse? 2.5

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.