Product Description: The PaxScan 4336R is a ruggedized, portable X-ray flat panel detector designed for mobile digital radiographic X-ray systems. It fits standard 14"x17" bucky trays and uses a Gigabit Ethernet interface for image display on a user-supplied workstation.
Technical Specifications:
  • Receptor Type: Amorphous Silicon with Charge Well Pixel™ Technology.
  • Conversion Screen: Options include Direct Deposit CsI, Detached CsI, and DRZ Plus.
  • Pixel Area: Total: 42.7 x 35.6 cm; Active: 42.4 x 35.3 cm.
  • Pixel Matrix: Total: 3,072 x 2,560; Active: 3,052 x 2,540.
  • Pixel Pitch: 139 μm.
  • Limiting Resolution: 3.6 lp/mm.
  • Image Quality: DQE and MTF values provided for GADOX and DD/CSI.
  • Sensitivity: 0.412 LSB/nGy for GADOX, 0.825 LSB/nGy for DD/CSI.
  • Energy Range: 40 - 150 kVp.
  • Fill Factor: 100%.
  • Scan Method: Progressive.
  • Data Output: Gigabit Ethernet.
  • A/D Conversion: 14-bits.
  • Cycle Time: Minimum 8 sec, standard 10 sec.
  • Exposure Control: Inputs: Prepare, Expose-Request; Outputs: Expose-OK.
Computer Requirements: Minimum 2.00 GB RAM and a Pentium dual-core CPU running at 2.0 GHz or equivalent.
Software: Includes ViVA™ for image acquisition and viewing, compatible with Windows® XP and Windows® 7 (32 bit).
Environmental Specifications:
  • Shock: High-shock tolerance.
  • Water Resistance: Yes.
  • Operating Temperature: 10°C to 35°C.
  • Storage Temperature: -20°C to +70°C.
  • Humidity: 10 to 90% non-condensing for both operating and storage.
  • Atmospheric Pressure: 70 kPa to 106 kPa for both operating and storage.
Weight Limit: Uniform load: 150 kg; Concentrated load: 100 kg.
Regulatory Compliance: UL 60601-1 for the U.S. and CSA 22.2 No. 601.1-M90 for Canada.
Mechanical Specifications: Weight: 8.6 lbs (3.9 kg); Housing Material: Aluminum; Sensor Protection: Carbon fiber plate and aluminum.
Power Specifications: Power Dissipation: 30 watts (continuous), 35 watts (max); I/O Interface Box: 100 - 240 VAC, 47 - 63 Hz.
Additional Notes: The PaxScan 4336R is designed to be integrated into a complete X-ray system by a qualified system integrator, who is responsible for obtaining FDA clearance for medical use.
See more

Catalog excerpts

PaxScan 4336R-1

X-RAY PRODUCTS Digital Image Receptor Product Description The PaxScan 4336R is the first ruggedizedportable X-ray flat panel detector designed formobile digital radiographic X-ray systems to fit existing 14"x17" standard bucky trays. Based upon the new Gigabit Ethernet interface, images are displayed on a user-supplied workstation. Technical Specifications Receptor Type Amorphous Silicon with Charge Well Pixel™ Technology Conversion Screen . . . . Direct Deposit CsI, Detached CsI, DRZ Plus Pixel Area Total . . . . . . 42.7 (h) x 35.6 (v) cm (16.8 x 14.0 inch) Active . . . . 42.4 (h) x 35.3 (v) cm (16.7 x 13.9 inch) Pixel Matrix Total . . . . . . . . . . . . . . . . . . . . . . . 3,072 (h) x 2,560 (v) Active . . . . . . . . . . . . . . . . . . . . . 3,052 (h) x 2,540 (v) Pixel Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 μm Limiting Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 lp/mm Software The software release includes ViVA™, a basic application for image acquisition and viewing on an end-user workstation or laptop running Microsoft® Windows™. The developer’s software package includes a “Virtual Command Processor” software interface that performs detector calibration, detector set-up, image acquisition, and image corrections. ViVA™ includes file type translators for .viv, .raw, .jpg, and .bmp file formats. Windows® XP and Windows® 7 (32 bit) compatible. Environmental Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-shock tolerance Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water resistant Energy Range Standard . . . . . . . . . . . . . . . . . . . . . . . . . 40 - 150 kVp Image Quality DQE @ 0 lp/mm DQE @ 1 lp/mm DQE @ 2 lp/mm DQE @ 3 lp/mm DQE @ Nyquist MTF @ 1 lp/mm MTF @ 2 lp/mm MTF @ 3 lp/mm MTF @ Nyquist Sensitivity Fill Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100% Scan Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Progressive Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. Gigabit Ethernet Temperature Range - Operating (at back cover) 10°C to 35°C (max.) (Ambient) - Storage . . . . . . . . . . . . . . . . . . . . . -20°C to +70°C Humidity - Operating (non-condensing) . . . . . . . . . . . . . . . . 10 to 90% Storage (non-condensing) . . . . . . . . . . . . . . . . . . . 10 to 90% Atmospheric Pressure - Operating . . . . . . . . . . . . . . 70 kPa to 106 kPa Storage. . . . . . . . . . . . . . . . . 70 kPa to 106 kPa Weight Limit Uniform load across entire carbon fiber surface . . . . . . 150 kg Concentrated 40mmdiameter load at the center . . . . . . . 100 kg Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Cycle Time (minimum / standard) . . . . . . . . . . . . . . . . . . . 8 / 10 sec. Sensor Protection Material . . . . . . Carbon fiber plate and aluminum Exposure Control . . . . . . . . . . . . . . . Inputs: Prepare, Expose-Request Outputs: Expose-OK Power Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 watts (cont.) 35 watts (max.) Computer Requirements RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.00 GB CPU . . . . . . . . . Pentium dual core running @ 2.0 GHz or equivalent * Without encloure I/O Interface Box . . . . . . . . . . . . . . . . . . . . . 100 - 240 VAC, 47 - 63 Hz (Up to 9m away from panel) ®PaxScan is a Registered Trademarks of Varian Medical Systems Manufactured by Varian Medical Systems Specifications subject to change without notice.

 Open the catalog to page 1
PaxScan 4336R-2

medical systems Product Specifications Drawings are for reference only Cable Replacement Cover |~2~| Denotes Approximate Center of Gravity [~3~| Active Area Dimension [~4~] Top Surface of Active Area [5] Hybrid Cable (Approximate 0 9.5MM) NOTE: As with all Varian Amorphous Silicon Image Receptors, the PaxScan 4336R is designed to be integrated into a complete X-ray system by a qualified system integrator. The system integrator medical systems 1678 South Pioneer Road Salt Lake City, Utah 84104 Varian Proprietary & Confidential Information. Use is prohibited without Varian's express written consent....

 Open the catalog to page 2

All Varian Oncology catalogs and technical brochures

  1. Halcyon

    15  Pages

  2. Eclipse

    7  Pages

Archived catalogs

  1. VitalBeam

    8  Pages

  2. Eclipse™

    2  Pages

  3. ProBeam 360

    2  Pages

  4. 360 ONCOLOGY

    3  Pages

  5. Nexus-DRF™

    2  Pages

  6. 2520DX

    2  Pages

  7. 1515DXT

    2  Pages

  8. 1308DXT

    2  Pages

  9. Clinac Brochure

    12  Pages

  10. Edge Brochure

    22  Pages

  11. NDI-452

    4  Pages

  12. M-101G

    6  Pages

  13. M-105SP

    6  Pages

  14. M-109

    6  Pages

  15. M-113

    6  Pages

  16. M-143

    6  Pages

  17. M-147SP

    6  Pages

  18. M-146

    6  Pages

  19. M-147

    6  Pages

  20. RAD-85S

    6  Pages

  21. M-149

    6  Pages

  22. M-151

    10  Pages

  23. M-152

    12  Pages

  24. M-153

    8  Pages

  25. PaxScan 3030+

    2  Pages

  26. M-171

    6  Pages

  27. PaxScan 4030E

    2  Pages

  28. 1313

    2  Pages

  29. Vitesse 3.0

    3  Pages

  30. BrachyVision

    7  Pages

  31. RapidArc

    8  Pages

  32. Vitesse? 2.5

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.