BonnieBone - 1

Bonnie Bone Marrow Biopsy™ Skills Trainer – 0240 User Manual 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 | fax 503.651.5052 | email info@vatainc.com | www.vatainc.co

Open the catalog to page 1
BonnieBone - 2

Thank you for your purchase of VATA’s Bonnie Bone Marrow Biopsy™ Skills Trainer Bonnie Bone Marrow BiopsyTM Skills Trainer - 0240 was developed with clinician input to provide a realistic simulation for teaching and practicing bone marrow biopsy procedures of the posterior spine and pelvic region. Bonnie was modeled from an average size female pelvic bone and spine to allow for the palpation of landmarks, such as the spinous process and the anterior and posterior iliac crests to facilitate proper biopsy needle placement. The Bonnie trainer includes a tilt base to simulate treating patients...

Open the catalog to page 2
BonnieBone - 3

Bonnie Bone Marrow BiopsyTM Skills Trainer - 0240 Product Components 2 1 3 5 Underside of iliac crest bone insert showing red marrow 1 Replaceable - Body Skin 5 Replaceable - Left & Right Iliac Crest 2 Replaceable - Puncture Site 3 10-Degree Tilt Base - 0244 4 5 Sets Replaceable Iliac Crest Bone Inserts - 0246 Bone Insert Base Tray with non-skid pads Baby Powder for skin surfaces Vaseline to lubricate the biopsy needles

Open the catalog to page 3
BonnieBone - 4

Set-Up Instructions Bonnie Bone Marrow BiopsyTM Skills Trainer is ready to use right out of the box. Bonnie Bone Marrow BiopsyTM Skills Trainer can be oriented in either prone or side-lying positions to accommodate different set-ups. For side-lying positions, the Bonnie Trainer must be attached to the Tilt Base.

Open the catalog to page 4
BonnieBone - 5

Set-Up Instructions – Prone Position 1. Palpate to localize either the anterior of posterior iliac crest as well as the spinous process, to ensure proper needle placement. 2. Prior to performing biopsy skills training, be sure to apply Vaseline to the entire length of your biopsy needle. Failure to do so will reduce the useful life of the puncture site skin insert. To access to posterior iliac crest, identify the appropriate location for needle insertion by following your institution’s protocol. Puncture the skin through the puncture site skin insert. Similar to an actual biopsy procedure,...

Open the catalog to page 5
BonnieBone - 6

Set-Up Instructions – Side Lying Position 1. Slide the Bonnie trainer into the 10-degree angled slot on the tilt base. The Bonnie Bone Marrow BiopsyTM Skills Trainer is notched on both left and right sides to allow for orienting the trainer for side-lying positions. 2. Insert the two black thumbscrews at the bottom of the Bonnie trainer to properly secure the tilt base. Finger tighten the thumbscrews.

Open the catalog to page 6
BonnieBone - 7

Set-Up Instructions – Side Lying Position, Continued 3. The Bonnie trainer and tilt base are designed to have a close fit. Press down firmly to seat both pieces together. When properly positioned the Bonnie trainer with tilt base should be at a 10-degree tilt off vertical.

Open the catalog to page 7
BonnieBone - 8

Care & Maintenance Instructions 1. To access the underlying pelvic bone structure and posterior iliac crest bone inserts, lift the puncture site skin insert to separate it from the body skin shell. 2. Next remove the body skin shell by pulling the side in a outward direction as shown, to separate it from the pelvic bone structure. Lift the body skin shell away from the pelvic bone structure and set aside.

Open the catalog to page 8
BonnieBone - 9

Care & Maintenance Instructions, Continued Push to insert bone Pull to remove bone 3. The posterior iliac crest bone inserts are individually labeled with “L” for left and “R” for right. These can easily be removed by pulling out and inserted by pushing into place per the pictured instructions. Helpful Hints • Lubricate the entire length of the biopsy needle with Vaseline to increase the life of the puncture site skin insert. Failure to do so will result in a shorter useful life for the puncture site skin insert. Puncture site skin insert has been tested for up to 200 punctures before...

Open the catalog to page 9
BonnieBone - 10

Cleaning Instructions 1. Skills Trainer can be easily disassembled for cleaning. Wipe off any residual Vaseline on the skin surface before cleaning the trainer. 2. All surfaces can be cleaned using a mild soap and water or wiped with alcohol. 3. Dry the trainer with a non-linting towel. 4. Once the surface of the trainer is completely dry, apply supplied baby powder to remove any stickiness and wipe off any excess powder before placing trainer in the carrying case. Storage Instructions 1. Do not rest any objects on skin surface as this may leave a permanent imprint. 2. Place the model in...

Open the catalog to page 10
BonnieBone - 11

Bonnie Bone Marrow BiopsyTM Skills Trainer - 0240 Parts List The following items are available for purchase without returning your model. Additional replacement parts are available at www.vatainc.com. Product # Bonnie Bone Marrow BiopsyTM Skills Trainer Bonnie Bone Marrow BiopsyTM Skills Trainer Carrying Case Replaceable Body Skin Shell Replaceable Puncture Site Skin Insert 5 Sets - Replaceable Left & Right Iliac Crest Bone Inserts Replaceable Puncture Site Skin and 5-sets Left & Right Iliac Crest Bone Inserts

Open the catalog to page 11
BonnieBone - 12

You Might Also Like These Products... Chester Chest™ With New Standard Arm - 2400 Chester Chest™ With New Standard Arm - Darkly Pigmented - 2402 Peter PICC Line™ - 0600 Advanced Four-Vein Venipuncture™ Training Aid - 2365 Advanced Four-Vein Venipuncture™ Training Aid - Darkly Pigmented - 2366 308 South Sequoia Parkway, Canby, Oregon 97013 USA ph. 503.651.5050 | fax 503.651.5052 | email info@vatainc.com | www.vatainc.com

Open the catalog to page 12

All VATA catalogs and technical brochures

  1. 2365/2366

    12 Pages

  2. Chester_Chest

    16 Pages

  3. LF00999

    6 Pages

  4. VATA Catalog

    24 Pages