1410 / 1412-1

SPECIFICATIONS General Display • 10.4”/12” (800 x 600) • Up to 7, 10 wave trace On/Off (3ch ECG, SpO 4 IBP, Resp EtCO • Full ECG 7 wave display (I, II, III, aVR, aVL, aVF, V) Parameters (10EA) • ECG, SpO • HRV, APG detect analysis • 2 IBP, 2 Temp, EtCO Interface • RS-232 port, VGA Port, LAN, ECG output (opt.) Port. • SD Memory Card Port. Power • AC 100~240V, 50/60Hz, 80VA (MAX) • BATTERY: Li-ion (1 pack - 2 hours) (opt: 2 Pack - 4 hours) • DC 12V (optional) Thermal Printer (optional) • 3 channel • Speed: 12.5, 25, 50 mm/sec • Paper size: 58 mm Trend • Memory storage: 7 days (standard) • Tabular & Graphic Data Interval: 1, 5, 15, 30 min and 1 hour • Save up to 20 Event data Language • ENGLISH, FRENCH, SPANISH, GERMAN, ITALIAN, RUSSIAN, TURKISH, CZECH, ROMANIAN, PORTUGUESE (BRA), POLISH Physical Dimension • 280mm X 290mm X 175mm (11” x 11.5” x 63/4”) • Weight: 4.0Kg (9 lbs.) (without battery) • HR Range • GAIN • Sweep Speed • Pacemaker Mode • Arrhythmia Detect • ST Analysis • HR Calculation SpO • Range • Accuracy • Pulse Range • Accuracy • Low Perlusion • Setting Time • GAIN • Sweep Speed Respiration • Range • Apnea • Waveform NIBP • Technique • Measurement Range • NIBP STAT • NIBP VENOUS STAT IBP ICO (Optional) • Channel • CI, SV, SI, LVSW, LVSWI, RVSW, RVSWI, SVR, • Range SVRI, PVR, PVRI • Accuracy • Catheter: Swan-Ganz standard Thermodilution pulmonary • Catheter Artery Catheter (131HF7, 744hf75) • Edward Lifesciences TEMP • Channel • Range • Accuracy Tel: 1-502-671-1014 Toll Free: 1-877-329-7775 [email protected] www.vetlandmedical.com 3 leads (Standard), 5 leads (Optional) 3 Channel: 3 leads / 7 leads (Full Display) 12 Channel: 12 leads (Optional) 0~300 bpm (± 2 bpm) 2.5, 5, 10, 20, 30, 40, Auto mm/mV 6.25, 12.5, 25, 50 mm/sec Pacemaker Arrhythmia Detection (PNF, PNC) TAC, BRD, PVC, VTAC, ASY, BGM, TGM, VENT, VFIB, CPT, TPT, MIB, RonT Range: -9.9mm ~ +9.9 mm Resolution: 0.1mm 4~16 wave 0~100% 100~70% ± 2% 69~50% ± 3% 49~0% unspecified 0~300 bpm 0~240 bpm ±2 bpm, 241~300 bpm ±3 bpm 0.1% up to Wave out Time: Max 2 sec, 0.25, 0.5, 1, 2, 3, 4, Auto mm/mV 6.25, 12.5, 25, 50 mm/sec Optional Massimo SpO 0~200 rpm (±2% or ±2bpm) OFF, 10~40 sec 0.25, 0.5, 1, 2, 3, 4, Auto ohm display Oscillometric 0~300 mmHg 5~15 min 50~200mmHg 2 (standard), 4 (optional) -50~350 mmHg ±1% Yuta, Edward, Medex (Total 6 types) 2 (standard), 4 (optional) 0~50.0°C 25.0~50.0°C ± 0.1°C 0~24.9°C ± 0.2°C EtCO • Measurement Mode • Range • Resp Rate Respironics Mainstream/Sidestream 0~99 mmHg (0~9.9kPa / 0~9.9%) 0~150 bpm • AAHA compliant data importability to any practice management software • Print trends, reports or waves via internal printer or network printer • Remote viewing possible anywhere in the world via Smart Care System Multi Parameter Patient Monitor for Veterinary Critical Care Tel: 1-502-671-1014 | Toll Free: 1-877-329-7775 www.vetlandmedical.com | [email protected]

 Open the catalog to page 1
1410 / 1412-2

Multi Parameter Patient Monitor for Veterinary Critical Care Standard: ECG (3CH) • SpO • NIBP • RESP • 2TEMP • 2IBP • HR/PR • APG • HRV Optional: EKG (12CH) • 4TEMP • 4IBP • ICO • EtCO • Touch Screen • DC 12V Multi-­Gas Phaseln AB;; AX+, OR+ • VGA OUTPUT • MASSIMO SPO TECHNOLOGY • Versatile, portable-compact design • Intuitive color display • Validated Industries Best NIBP Technology with automatic & STAT modes • 7 days tabular & graphic trend data storage...

 Open the catalog to page 2

All Vetland Medical catalogs and technical brochures

  1. VWA-3100

    2  Pages

  2. RSA/RTA-0021

    2  Pages

  3. VDA-4100

    2  Pages

  4. Eco Sorb

    1  Page

  5. EX 3000

    2  Pages

  6. V1407

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.