Protect Yourself UV radiation is dangerous for unprotected eyes and skin. Users must protect themselves against UV radiation by wearing glasses or face shields. The MP-80 is recommended for protection of the eye and the face. The MP-800 is a face shield with two lateral protections to cover the operator's ears in addition to its eyes and face. Comfortable and efficient, the LP-70 glasses provide total protection to the eyes. Electromagnetic Spectrum (Enlargement Of Ultraviolet Region) Cosmic Rays Gamma Rays Radio Waves
Open the catalog to page 2VILBER’s UV Master Technology™ VILBER is the UV fluorescence expert since 1951. Our own UV lamps emit highly concentrated UV radiation. This output is reinforced with the use of our exclusive Ondulex™ reflector, especially polished to reflect the maximum of the light to the outside. Combined with our innovative range of special UV filters, our unique fluorescence sources dramatically improve the quality of gel visualization, documentation and create unrivaled application capabilities. ISO 9001 VILBER has been approved for registration to ISO 9001:2015. This is an indication of VILBER’s...
Open the catalog to page 3LONG LIFETIME UNIQUE ELECTRODE Thanks to our special lamp Thousands hours glass filters and coating. About UV Tubes Our original UV tubes emit highly concentrated UV radiation. They use a special ultraviolet ray glass which efficiency transmits the ultraviolet rays. Ultraviolet is located at shorter wavelengths compared to visible light radiation and produces high energy potential
Open the catalog to page 4Relative Energy Relative Energy Relative Energy
Open the catalog to page 5LONG LIFETIME ONDULEX REFLECTOR Lamp stand or holder Anodized aluminum About UV Lamps Our large choice of filtered and unfiltered lamps range from 6 to 3×40 w-watt. Our filtered lamps are ideal for the fluorescence detection. The BL-BlackLight lamps provide a large light spectrum with 365nm UV and visible light. The UV germicidal 254nm lamps help to prevent contamination in research laboratories.
Open the catalog to page 6Lamps 6W - Filtered Model Black Light Black Light Black Light Black Light
Open the catalog to page 7Lamps 30W -Unfiltered Model Black Light Black Light Black Light Irradiation Surface For A Height Of About 2m Power (W) Lamps Stands & Handlers Models
Open the catalog to page 8Highly Concentrated UV Radiations Reflect The Maximum UV Output
Open the catalog to page 9LONG LIFETIME FILTER STAINLESS STEEL FRAME Unlimited life expectancy for Ideal to switch from short gel visualization to longer preparative work. ADJUSTABLE DUAL INTENSITY About UV Tables We provide first-class UV transilluminators for documentation and preparation in different dimensions and configurations. Our innovative Super-Bright filter stops all the visible light emitted by the tubes. As the UV tubes are no more visible, the Super-Bright improves dramatically the quality of gel visualization and documentation.
Open the catalog to page 10Intensity (uW/cm²) Blue Light Blue Light White Light White Light Transilluminators 8W - Multiband Model Conversion Screen Model From This Wavelength (nm) White Light
Open the catalog to page 11LARGE CAPACITY Ideal for small or large sample. EASY ACCESS TO DARKROOM Protect the user from combined at your convenience. About UV Darkrooms Our UV darkrooms provide a large effective capacity and a high detection sensitivity. They could offer any combination of UV sources, simultaneously or not. The UV darkroom CN-6 is supplied without lamps and allows different lighting possibilities according to the user’s choice.
Open the catalog to page 12Multichannel darkroom without tubes, chose betwen the set below Darkroom without lamp, the wavelengths can be chosen, between 254 nm or 365 nm - VL-6 Models Removable Lamps That Can Be U s e d F o r H a n d -H e l d A p p l i c a t i o
Open the catalog to page 13PHOTO-ELECTRIC SENSOR TIME OR ENERGY MEASURE MICROPROCESSOR CONTROLLED INTERCHANGEABLE SENSOR Wavelength dependent sensors could be used one at a time. About UV Radiometers The radiometers measure UV light intensity for a specific wavelength (254nm, 312nm or 365nm). They are designed for an accurate and direct measurement of the UV radiation. All our radiometers use a silicon photoelectric sensor for a direct measurement of the UV intensity and thus do not convert UV into visible light.
Open the catalog to page 14Sensors Model Precise, Highly Acurate And User Friendly Measure the UV radiation dose a s a f u n c t i o n o f t i m e o r e n e r g y.
Open the catalog to page 15LONG LIFETIME ONDULEX REFLECTOR Protective quartz disk on the chamber in stainless steel. About UV Bio-Link The Bio-Link crosslinker is a UV irradiation system, mainly dedicated to the linking of nucleic acid to membranes and elimination of PCR contamination. Its innovative design ensures unique features.
Open the catalog to page 16Protective Quartz Disk On the UV Sensor Cell
Open the catalog to page 17LONG LIFETIME ONDULEX REFLECTOR Protective quartz disk on the chamber in stainless steel. About UV Bio-Sun The BioSun is a complete, microprocessor controlled UV irradiation system designed for Petri dishes or micro-plates. Based on a programmable microprocessor, the system constantly monitors the UV light emission. The irradiation stops automatically when the energy received matches the programmed energy. Thanks to its advanced UV sensors, the irradiation cycles are perfectly reproducible, regardless of the intensity fluctuation of the UV source. Just program your energy and Bio-Sun...
Open the catalog to page 18FLEXIBILITY • UVA, UVB or UVA & UVB irradiation • UVC 254nm germicidal lamps fo tray sterilisation • Silicon photoelectric sensor for direct measurement of the UV intensity PERFORMANCE • Scientific grade UV Irradiation sytsem • Perfectly reproducible UV irradiation cycles • Highly homogeneous UVA and UVB sources (312 and 365nm) MULTI-APPLICATIONS • Data acquisition controlled by micro-processor • Constant monitoring of the received energy versus the programmed energy T • Temperature, UV intensity, and time passed supervision EASY & INTUITIVE • Powerful cooling system • Optional software...
Open the catalog to page 19HEADQUARTERS Vilber Lourmat ZAC de Lamirault Collegien F-77601 Marne-la-Vallee cedex 3 France Phone : + 33 (0) 1 60 06 07 71 info@vilber.com GERMANY Vilber Lourmat Deutschland GmbH Wielandstrasse 2 D-88436 Eberhardzell Deutschland Phone : + 49 (0) 7355 931 380 info@vilber.de CHINA Vilber China Room 127 Building A N° 111 Yuquangying Fengtai District – Beijing China Phone : + 86 1361 1131 545 info@vilber.cn
Open the catalog to page 20All Vilber GmbH catalogs and technical brochures
-
NEWTON 7.0
6 Pages
-
SIMPLY E-BOX PRECISE
6 Pages
-
E-BOX
1 Pages
-
Spaide FAF Filters
2 Pages
-
DRI OCT Triton series
4 Pages
-
INFINITY
1 Pages
-
FUSION SOLO S
1 Pages
-
FUSION FX
1 Pages
-
FUSION FX SPECTRA
1 Pages
Archived catalogs
-
NEWTON 7.0 VIVO
1 Pages