video corpo

VX118

VX118

VX118

Product catalog summary
Overview
The VX 118 is a comprehensive, fully automatic device for refraction and topography, designed for precise vision analysis and the detection of corneal pathologies such as keratoconus. It integrates advanced technologies for high-end refraction and vision analysis, including the Shack-Hartmann sensor and Placido disk.

Key Features
  • Extremely precise refraction measurements, including cylinder and axis, even on small pupils (1.2/1.4 mm).
  • 1400 points of analysis for a 7 mm pupil, with measurements for both daytime and nighttime vision.
  • Analysis of low-order and high-order optical aberrations.
  • Non-contact pachymetry and anterior chamber analysis using a Scheimpflug camera.
  • Data export capabilities via Wi-Fi, USB, and office networks.

Technologies Used
  • Wavefront analysis with Shack-Hartmann sensor.
  • Corneal curvature measurement using Placido disk.
  • Retro illumination and Scheimpflug camera for cataract and opacity monitoring.

Technical Specifications
  • Dimensions: W 320 mm x D 555 mm x H 540 mm; Weight: 27 kg.
  • Display: 10.1” multi-touch TFT screen.
  • Voltage: 100/120, 220/240 V CA, 50/60 Hz, 250 W.
  • Output: RS232 / USB / VGA / LAN.
  • Spherical power range: -20D to +20D; Cylinder power range: 0D to +8D.
  • Measuring area: Min. ø 2 mm - Max. 7 mm.
  • Pachymetry range: 150-1300 μm; Resolution: +/- 10 microns.
  • Corneal topography: 24 rings, 6,144 measuring points, over 100,000 points analyzed.

Benefits
  • Fully automated 3D and R/L eye alignments with high reproducibility.
  • Quick detection of refraction and higher order aberrations.
  • Significant time savings and optimal comfort due to ergonomic design.
  • Delegation of tasks and easy transfer of patient measurements to doctors.
See more

Catalog excerpts

VX118-1

One-Touch High-end Refraction, Vision Analysis, Higher Order Aberrations and Topography

 Open the catalog to page 1
VX118-2

VX118 The VX 118 is a unique, complete, and fully automatic refraction and topography device. The VX 118 features variations of refraction, pathologies such as keratoconus, and fitting of contact lenses with integrated topography. Top of the line non-contact pachymetry and analysis of the anterior chamber by the bias of a Scheimpflug camera.” With full integration in mind, the VX 118 is designed to be able to export measurements and findings and archive your data using Wi-Fi, USB key, office networks, etc. REFRACTION AND VISUAL PERFORMANCE Simulations of visual acuity > Extremely precise refraction...

 Open the catalog to page 2
VX118-3

> Screening for loss of contrast and penetration of light > Effect of the opacity on the quality of vision Opacity monitor CUSTOMIZABLE REPORTS This document is non-contractual. – Photos: Eric Bienvenu – Ind.00– 07/15 TECHNOLOGY: Retro illumination, Scheimpflug camera, Shack-Hartmann matrix. OFFLINE VERSION PATIENT MANAGEMENT SOFTWARE EHR/EMR

 Open the catalog to page 3
VX118-4

Technical data General Working distance 10,1” (1 024 x 600) TFT screen Multi-touch screen Observation area Printer Voltage ø 14 mm Integrated black and white - external color available 100/120, 220/240 V CA, 50/60 Hz, 250 W Medical directive AR & power mapping (Wavefront) Spherical power range Cylinder power range Measuring area Number of measuring points Acquisition time. Pachymetry, IC angle and pupillometry Method Pachymetry range Pachymetry resolution Pupil illumination Retro illumination Corneal topography Number of rings Number of measuring points Fully automated Number of points analyzed...

 Open the catalog to page 4

All Visionix catalogs and technical brochures

  1. weco e6 s line

    12  Pages

  2. weco e5

    12  Pages

  3. weco e32

    8  Pages

  4. weco e12

    6  Pages

  5. weco e7

    6  Pages

  6. 2022 vx40

    6  Pages

  7. vx650

    12  Pages

  8. vx100 serie

    12  Pages

  9. vx65

    8  Pages

  10. nexy A.I

    8  Pages

  11. | optovue solix

    16  Pages

  12. optovue iseries

    16  Pages

  13. Nexus,

    4  Pages

  14. briot scan8

    6  Pages

  15. briot couture

    8  Pages

  16. VX90 VISIONIX

    4  Pages

  17. WECO E.5

    6  Pages

  18. VX130

    6  Pages

  19. VX120

    6  Pages

  20. VX110

    4  Pages

  21. VX40

    2  Pages

  22. VX 60

    2  Pages

  23. VX55

    4  Pages

  24. VX130+

    8  Pages

  25. VX120+

    6  Pages

  26. VX90

    4  Pages

  27. VX36

    4  Pages

  28. perception2

    6  Pages

  29. emotion2

    6  Pages

  30. E.32 weco

    6  Pages

  31. E.12 weco

    4  Pages

  32. C.4

    4  Pages

  33. Evolution GT

    4  Pages

  34. VX 40

    2  Pages

  35. C.6

    4  Pages

  36. Attitude

    12  Pages

  37. Evolution

    6  Pages

  38. PERCEPTION

    6  Pages

  39. E.6

    6  Pages

  40. E.5

    6  Pages

  41. E.3

    4  Pages

  42. WECO E.1

    4  Pages

  43. Eye Refract

    8  Pages

  44. VX 55

    4  Pages

  45. VX 120

    6  Pages

  46. EMOTION

    6  Pages

  47. VX 24

    2  Pages

  48. VX 22

    4  Pages

  49. WECO C.6

    6  Pages

  50. VX BOX II

    4  Pages

Archived catalogs

  1. VX 130

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.