1. Catalogs
  2. Vivaproducts, Inc.
  3. Vivaspin® 15R and Vivaspin® 20

Vivaspin® 15R and Vivaspin® 20

Vivaspin® 15R and Vivaspin® 20

Vivaspin® 15R and Vivaspin® 20

Product catalog summary
Overview: Vivaspin® ultrafiltration concentrators are disposable devices designed for concentrating biological samples. The Vivaspin® 15R is suitable for sample volumes from 2 to 15 ml, while the Vivaspin® 20 can handle up to 20 ml. These devices feature a patented vertical membrane design that minimizes fouling and enhances concentration speed.
Applications: Vivaspin® devices are used for concentrating urine samples for electrophoresis, desalting, and buffer exchange. They are recommended for use with capillary systems by Sebia and Helena Labs.
Features and Benefits: The vertical membrane design ensures fast filtration rates, while integrated dead stops prevent over-concentration. The devices are made from low binding materials to ensure high sample recovery and are available in a wide range of molecular weight cutoffs.
Technical Specifications: The Vivaspin® 15R and 20 have different capacities depending on the rotor type used. Both have a total length of 116 mm and a width of 30 mm. The active membrane area is 3.9 cm2 for the 15R and 6.0 cm2 for the 20. The hold-up volume is less than 20 µl.
Materials of Construction: The body and filtrate vessel are made of polycarbonate, while the concentrator cap is polypropylene. The membrane materials include HY and PES.
Equipment Required: A centrifuge with a rotor cavity to fit 50 ml conical bottom tubes is required. The fixed rotor minimum angle is 25°, with a maximum speed of 6,000 g for fixed rotors and varying speeds for swinging bucket rotors.
Membrane Selection Guide: Different membranes are available, including Polyethersulfone (PES) for general purposes, Cellulose Triacetate (CTA) for low non-specific binding, and Hydrosart® (HY) for low protein binding.
Performance Characteristics: The document provides detailed performance data for different molecular weight cutoffs and sample types, indicating time to concentrate and sample recovery percentages.
Ordering Information: The document lists various Vivaspin® models with different molecular weight cutoffs and pack sizes, along with their corresponding product codes.
Manufacturer and Contact Information: Manufactured by Sartorius Stedim Lab Ltd., with North American distribution by Vivaproducts. Contact details and website information are provided for further inquiries and ordering.
See more

Catalog excerpts

Vivaspin® 15R and Vivaspin® 20-1

Vivaspin® 15R and Vivaspin® 20 Your Source for Clinical & Biological Concentrators Call us at 800-456-4633 Concentration & Purification of Clinical Biological Samples Technical Specifications Vivaspin® Vivaspin® Fixed angle rotor 12.5 ml 14 ml Swinging bucket rotor 15 ml 20 ml (membrane & support) Dead stop volume** 30 pl 50 pl Vivaspin® ultrafiltration concentrators are disposable devices for biological samples. Vivaspin® 15R is suitable for sample volumes from 2 to 15 ml while Vivaspin® 20 can handle samples up to 20 ml. The patented vertical membrane design and thin channel filtration chamber (US 5,647,990) minimizes membrane fouling and provides high speed concentrations. Vivaspin® 15R is supplied with the Hydrosart® membrane to provide excellent sample recovery. Vivaspin® devices are for single use and some Vivaspin® 20 products are intended for in vitro diagnostic (IVD) applications. Vivaspin® Applications — Concentration of urine prior to electrophoresis for diagnosis of multiple myeloma and amyloidosis. — Desalt and exchange buffers for urine samples prior to capillary electrophoresis. Vivaspin® 20 is recommended by Sebia and Helena Labs for their capillary systems. **Dead stop volume may vary depending on sample, temperature and rotor Body Polycarb. Polycarb. Filtrate vessel Polycarb. Polycarb. Concentrator cap Polyprop. Polyprop. Polycarb. = Polycarbonate, Polyprop. = Polypropylene * See other side for membrane descriptions Equipment Required Centrifuge Rotor cavity To fit 50 ml (30 mm) conical bottom tubes To fit 50 ml (30 mm) conical bottom tubes Fixed Rotor-Minimum Angle Fixed Rotor-Max. Speed Features Benefits Vertical membrane design Fast filtration rates. Integrated dead stop Reduces risk of concentration to dryness. Low binding materials High sample recovery. Wide range of MW cutoffs Choose MW cutoff for your specific application. Large Vivaspin® family Can process samples from 100 pl to of devices 20 ml with similar methodology. Swinging Bucket-Max. Speed ** lower g force for these > 100,000 PES Pipettes for Sample Delivery & Recovery Fixed or variable volume may be used. For maximum recovery, a thin gel loader type is recommended.

 Open the catalog to page 1
Vivaspin® 15R and Vivaspin® 20-2

Membrane Selection Guide Polyethersulfone (PES) A good general purpose membrane for most solutions. Has low fouling characteristics with very good flow rates. Tolerates a broad pH range (from 1 to 9). Good hydrophilic properties with very low non-specific binding. Cast without a membrane support that could bind filtered solutes. Use when recovery of filtrate is most important (free drug or hormone testing). Similar to regenerated cellulose but with better performance characteristics and low protein binding. Good choice for concentration and desalting of proteins that may bind to other membranes...

 Open the catalog to page 2

All Vivaproducts, Inc. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.