1. Catalogs
  2. Volk
  3. eye check
video corpo

eye check

eye check

eye check

Product catalog summary
Applications for Use
Volk Eye Check is a handheld ocular measurement device designed to improve contact lens fitting by providing real-time, objective data. It helps identify candidates for specialty lenses and provides specific measurements to facilitate proper lens fitting. Key parameters measured include Horizontal Visible Iris Diameter (HVID), pupil diameter, and lid margin to pupil margin.

Integration and Ease of Use
The device features USB and WiFi connectivity for real-time data transfer to PCs, ensuring seamless integration into clinical environments. It has a user-friendly interface with a touchscreen and point-and-click results.

Support and General Patient Care
Software upgrades keep the device up-to-date with the latest features. It serves as a complementary diagnostic tool, aiding in tracking ocular health over time.

Pediatric Examination
Eye Check provides consistent, objective measurements, facilitating quick analysis of uncooperative patients and supporting other examination methods.

Technical Specifications
The device features a 16Mp image resolution, a 3.2” TFT-LCD touchscreen, and various automatic exposure settings. It includes a Xenon flash for subject illumination and has storage capabilities with an 8GB microSD card.

Contact Lens Module
The module provides accurate measurements for professional contact lens fitting, improving the fit of both standard and specialty lenses. It measures parameters such as iris diameter, pupil size, lid positions, and pupil eccentricity.

Benefits
The device reduces drop-out rates by identifying the best fit lens quickly, eliminates trial and error, and improves office workflow by freeing time for optometrists or ophthalmologists. Measurement data can be transferred to manufacturers for custom lens design.
See more

Catalog excerpts

eye check-2

Objective data. Faster decisions. Superior care. Volk Eye Check is an electronic handheld ocular measurement device providing real time, objective data to enable smarter, faster decisions. Applications For Use > Contact Lens Fitting Over 20% of patients are candidates for specialty fit contact lenses. Research data shows that of 37- 38 Eye Check can be incorporated seamlessly into your environment, bringing instant value as a simple method for quick, costeffective ocular measurements. million contact lens users in the US1, 16% or 6,000,000 patients drop out of contact lens wear annually 2. Of...

 Open the catalog to page 2
eye check-3

> General Patient Care Accurate Output Used as a routine complementary diagnostic and data gathering tool, Eye Check measurements may be usefully gathered and recorded to track patient ocular health over time. "I used Eye Check as a diagnostic tool to help with my patient management. Plus it helped me to understand how I could improve the fitting of patient's contact lenses." Erik Roberstad, Interoptik, Tonsberg, Norway Eye Check's consistent outputs provide objective accurate measurements. Ease of use enables quick analysis of uncooperative patients to support other examination methods such...

 Open the catalog to page 3
eye check-4

Tech n ical S p eci f i cati on s 16Mp – 4608 x 3440 pixels TFT-LCD, 3.2”, 400 x 800 pixels, 16M colors Auto Exposure, Auto White Balance, Auto ISO Subject illumination Xenon Flash, GN3.1, Auto intensity, 100µS duration Fixation target 11x Visible Light LEDs flashing at approx 6Hz Width – 163mm Height – 64mm Depth – 26mm (lens retracted) Depth – 37mm (lens extended) Weight (with batteries) 1x Rechargeable, Li-ion, 3.7v, 1020mAh 2x AAA Alkaline Volk Optical Inc. | 7893 Enterprise Dr., Mentor, OH 44060 | P 440.942.6161 | E [email protected] ML-1015 Copyright© Volk Optical Inc. Rev. March 2014 Image...

 Open the catalog to page 4
eye check-5

Contact Lens Module Ideal Contact Lens Fitting - Improving First-Time Fit Ocular Measurement Device Simple. Fast. Accurate. Volk Eye Check Contact Lens Module provides accurate measurements of the key parameters needed for professional fitting of contact lenses. These measurements are a useful aid in standard and specialty contact lens fitting and optical design. > Reduce drop-out rates by quickly pointing to the best fit lens. PRIMARY FUNCTIONS > Effectively screens patients whose eye parameters, such as cornea size, pupil size, and pupil position, require non-standard lens parameters and optics....

 Open the catalog to page 5
eye check-6

- Patient report - Contact Lens Measurements Age 23 Gender Female Session date B. Pupil Center to Upper Lid C. Pupil Center to Lower Lid D. Horizontal Visible Iris Diameter E. Vertical Visible Iris Diameter F. Diagonal Visible Iris Diameter Vertical Pupil Eccentricity Horizontal Pupil Eccentricity Inter-Pupil Distance Pupil Diameter Difference HVID Difference ML-1015s Copyright© Volk Optical Inc. Rev. Jan 2015

 Open the catalog to page 6

Archived catalogs

  1. volk catalog

    44  Pages

  2. Pictor Plus

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.