IRATHERM®1000M Brochure
1 /4Pages

IRATHERM®1000M Brochure

IRATHERM®1000M Brochure
1 /4Pages

Catalog excerpts

IRATHERM®1000M Brochure-1

APPLIED BIOMEDICAL TECHNOLOGIES in Whole-Body Hyperthermia with wIRA Infrared-A Radiation for Whole-Body Hyperthermia

 Open the catalog to page 1
IRATHERM®1000M Brochure-2

Water-filtered infrared-A radiation -working principle and benefits The spectral transmission of skin starts at a long wave visual light of about 600 nm wavelength (see “Visual”) and passes the whole infrared-A until its upper long wave limit of about 1.400 nm wavelength. In contrast to that, the skin is nearly impenetrable to heat radiation from the spectral regions of infrared-B and infrared-C. Therefore, one can speak of “deepacting heat” in the case of infrared-A heat radiation, whereas with infrared-B and infrared-C radiation we speak only of “surface heat”. Water is the appropriate choice...

 Open the catalog to page 2
IRATHERM®1000M Brochure-3

Patient Monitoring with IRAsoft IRATHERM ® 1000M Highlights • solely skin-tolerable, water-filtered infrared-A heat radiation (wIRA) • uniform irradiance across the entire patient • rapid increase in body-core temperature (up to 39°C in approx. • high lying comfort • permanent and all-round access to the patient • cost and time-saving cleaning after therapy session • user-friendly monitoring Fully integrated transducer hardware in IRATHERM ® 1000M for signal processing. The purpose is to collect and provide various information. Via standard serial interface, relevant data is continously transferred...

 Open the catalog to page 3
IRATHERM®1000M Brochure-4

Exceptional homogeneity of wIRA in the patient level Cl Technical Data IRATHERM ® 1000M water-filtered infrared-A radiation (wIRA) 780 until 1400 nm wavelength Full spectrum radiation 400 until 1900 nm wavelength Irradiance 0 - 1400 W / m2 Power consumption 6.9 kW / 9.6 A / 3x 10 A / 400 V / 230 V Cooling-water consumption min. 4 l / min. Manufacturer / Distributor: Von Ardenne Institute of Applied Medical Research GmbH Zeppelinstr. 7 | 01324 Dresden | Germany Subject to technical change without notice.

 Open the catalog to page 4

All Von Ardenne Institute of Applied Medical Research catalogs and technical brochures