vulkan_catalogo_internal_hex
28Pages

{{requestButtons}}

Catalog excerpts

vulkan_catalogo_internal_hex - 2

Index Vulkan® Internal Hex. Implant System 3 About us Vulkan Internal Hex. Implant ® Implant Design and Properties VLA® Surface Treatment and Plasma Cleaning Sizes Guide Technical Specification Surgical Protocol Implant Driver and Packaging Step-by-Step Implant Placement Vulkan Internal Hex. Prosthetic Solutions and Tools ® Main Components Transepithelial Multi-Use System ® Vukan Tissue Care ® Overdenture VulkanLoc System CAD-CAM Components Surgical and Prosthetic Tools How we work Innovation, Precision and Quality Clinical Cases

Open the catalog to page 2
vulkan_catalogo_internal_hex - 3

Designed and made in Barcelona, one of the most advanced cities in the world in biotechnology About us Vulkan® is a modern, cutting-edge European dental implant brand, established in Barcelona (Spain) in 2013. Vulkan® was born out of our long and recognized expertise in the field of dental implantology. Also, because of our links with highly regarded companies and professionals in the sector and our close ties with the strong and world-renowned local biotechnological network. As a manufacturer of implants and dental prosthetic solutions, our added value is based on the high quality and...

Open the catalog to page 3
vulkan_catalogo_internal_hex - 4

Vulkan® Internal Hex., the most innovative design with the latest technology in each area of the implant Polished coronal region Polished and beveled surface of 0.5 mm. Aids the proper healing of the perimplantary mucogingival tissue, promoting the hygiene in the supracrestal area. Hinders the adhesion of bacterial plaque. Diminishes the risk of perimplantitis. Micro-slot in cortical area High primary stability at the cortical level. Suitable for immediate loading treatments with bone types lll and lV. Decrease of occlusal loading stress. Reduces the risk of cortical bone resorption. Double...

Open the catalog to page 4
vulkan_catalogo_internal_hex - 5

Internal hexagon connection of high fit Absence of micromovements (minimum GAP). Optimum sealing. Only 5 µm tolerance in manufacturing. Effective occlusal loading distribution. High resistance to torsional loading. High fit accuracy of dental attachments. Uniform platform suitable for all diameters. Simplicity in the process. Trapezoidal thread profile Optimal load distribution. Facilitates self-tapping function. Extensive bone contact surface. Atraumatic tapered apex Facilitates self-tapping to improve maneuverability. Blunt tip minimizes the risk of injuring anatomical structures....

Open the catalog to page 5
vulkan_catalogo_internal_hex - 6

VLA® Surface treatment Proven Guarantee of Success The Vulkan® IN·HEX implant has been subjected to a treatment consisting of sandblasting + double acid etching creating a surface with optimum roughness of 1.4 µm. This is a widely studied surface that provides a microstructure that stimulates the osseointegration of the implant. The VLA® surface treatment presents success rates of 98%-99%. This microstructure also ensures a large contact area between implant and bone, providing the maximum BIC (Bone Implant Contact). The Cleanest Implant In addition, an innovative final cleaning technique...

Open the catalog to page 6
vulkan_catalogo_internal_hex - 7

Vulkan® Internal Hex., the cutting-edge implant that meets all your needs * All Vulkan® Internal Hex. Implants include the Cover Screw (VINHTC) in the same pack

Open the catalog to page 7
vulkan_catalogo_internal_hex - 8

Technical specifications One Prosthetic Platform for All Implant Diameters

Open the catalog to page 8
vulkan_catalogo_internal_hex - 9

Technical specifications The best titanium for the most advanced implant In general, scientifically-proven dental implants are made of Titanium Grade 4. This material is known for providing better biocompatibility than Titanium Grade 5, because it has more pure titanium. However, although Titanium Grade 5 is less biocompatible, it has superior mechanical properties than Titanium Grade 4. This is the reason why Titanium Grade 5 is most commonly used in prosthetic components and Titanium Grade 4 in implants. The determining factor in choosing between one material or another is their...

Open the catalog to page 9
vulkan_catalogo_internal_hex - 10

Surgical Protocol These indications have been made for guidance (only). Bone drilling must be done carefully and taking into account the different bone density characteristics (Type I-IV). Important considerations (to be taken) during bone drilling · Use copious/profuse external irrigation of pre-refrigerated NaCl at 5ºC solution. · Prepare the implant bed site with sequential drilling (straight up-and-down motion during osteotomy). · Drill the osteotomy using light pressure. Recommended drill speed: (Must be individualised based on the bone density type) Pilot Drill Countersink Drill Soft...

Open the catalog to page 10
vulkan_catalogo_internal_hex - 11

Surgical Protocol Soft Bone (Type III/IV) Hard Bone (Type I/II) Countersink Drill Soft Bone (Type III/IV) Hard Bone (Type I/II) Countersink Drill Soft Bone (Type III/IV) Hard Bone (Type I/II)

Open the catalog to page 11
vulkan_catalogo_internal_hex - 12

Smart Implant Driver Vulkan® Internal Hex. √ Transportsfitthe implant by friction √ Controls the orientation of the faces of the connection. √ Visual indicator of implant depth insertion √ Places the cover screw with its 1.27 Hex tip Titanium holders Cover screw included Contra-Angle Driver Short Ratchet Driver Short

Open the catalog to page 12
vulkan_catalogo_internal_hex - 13

Step-by-Step Implant Placement STEP 1 Lift off the coloured cap to open the vial containing the implant. Place the cap into a sterile field. The implant cover screw comes attached to the top of the cap. STEP 2 Attach the implant driver to the contra angle. STEP 3 Connect the contra angle driver to the implant by exerting slight axial pressure. They will remain attached because the driver presents an elastic retention feature (rubber dots) in the area that connects to the implant. Remove the implant from the vial and carry it to the implant bed. STEP 4 Begin inserting th implant with the...

Open the catalog to page 13
vulkan_catalogo_internal_hex - 14

Step-by-Step Implant Placement STEP 5 Insert the implant 75%of it's lengthts, maximum torque 30-35 Ncm STEP 6 Finalize the implant installation manually, preferably with the dynamometric ratchet at maximum torque set to 40-45 Ncm STEP 7 Remove the cover screw from the vial cap with the H1.27 hand driver. STEP 8 Hand-tight the cover screw into the implant with a maximum torque of 10Ncm.

Open the catalog to page 14
vulkan_catalogo_internal_hex - 16

Vulkan® Internal Hex., Prosthetic Solutions and Tools Introduction Reliable and innovative prosthetic solutions ensure the perfect fit and maximum robustness. As a result of our advanced manufacturing process, we obtain a tolerance of only 5 µm, guaranteeing a perfect and extremely accurate sealed connection of the prosthetic components. Index Prosthetic Solutions and Tools 17-18 Main Components Transepithelial Multi-Use System Vulan Tissue Care Overdenture VulkanLoc System CAD-CAM Components Surgical and Prosthetic Tools - Surgical kit Single Prosthetic Driver All Vulkan® Internal Hex...

Open the catalog to page 16

All Vulkan Implants catalogs and technical brochures