video corpo cad

Endodontics
16Pages

{{requestButtons}}

Catalog excerpts

Endodontics - 1

People have Priority

Open the catalog to page 1
Endodontics - 3

PEOPLE HAVE PRIORITY Product overview of Entran, Endo Cursor, Endea, Endo NiTi 6-7 Endea, Endo NiTi 12-13

Open the catalog to page 3
Endodontics - 4

The stakes are high. We are working with people. Our most important tool is experience: W&H has been manufacturing high-quality handpieces and contra-angles since 1890. And the company has produced genuine advances in the field of endodontics over the years. The secret of our success: W&H has always placed people – regardless of whether they are partners, customers, patients or employees – in the centre. An example. We know: even educated people prefer not to read long introductions. We therefore stop here. 4 People have Priority W&H at a glance > Head office in Austria > 980 employees...

Open the catalog to page 4
Endodontics - 5

Christina Pfaffinger Employee at W&H Bürmoos

Open the catalog to page 5
Endodontics - 6

»A dream comes true: wireless working! Complete freedom of movement with no obstacles.« Dr. med dent. Holger Dennhardt specialist for dentistry and odontology, specialist for endodontics. »I can keep using my hand files!« Dr. Manfred Krah specialist for dentistry and odontology. »The smallest head! I have an outstanding view into the patient‘s mouth.« Endea Dr. Dr. Simon Enzinger specialist for oral and maxillofacial sur

Open the catalog to page 6
Endodontics - 7

Your advantages at a glance > Wireless for complete freedom of movement > Contra-angle attachment with extremely small head for the best possible access to the treatment site > Torque limiting and torque control > Auto reverse and auto forward mode > Reliability with long-life Li-ion battery > Ergonomic drive handpiece for fatigue-free and comfortable working > Contra-angle attachment thermo washer disinfectable and sterilizable More information from page 9 Your advantages at a glance > Proven hand fi les can still be used > Oscillating fi le movements > Fast and fatigue-free working >...

Open the catalog to page 7
Endodontics - 9

Absolute freedom of movement Cordless and safe: Entran is an easy-to-use endodontic system that is safe Nickel-titanium files Small head Safety functions Precise, fast and efficient The extremely small head The autoreverse and autoforward preparation ofthe root canal enlargesthe field of vision and modes with automatic safety stop with 360° rotation. offersthe best possible access minimize the risk of file breakage. Torque control The LED control ring lights up when over 75 % ofthe set torque Maximum comfort Economically shaped drive attached to the drive handpiece as required. This means...

Open the catalog to page 9
Endodontics - 10

Endea Endo Cursor

Open the catalog to page 10
Endodontics - 11

Ideal for use with hand files Fast, efficient and convenient. The Endea Endo Cursor supports your work with proven hand files, except that it is motorized. It makes your work significantly faster and virtually fatigue-free. Stainless steel hand files Root canal preparation with 60° rotary fi le motion. Small head and slim shape Excellent view with optimum access to the treatment site, particularly in the molar region.

Open the catalog to page 11
Endodontics - 13

Contra-angles specially for nickel-titanium files Versatile, precise and practical. The Endea and Endo NiTi contra-angles guarantee the best possible access to the treatment site and have been specially designed for efficient working with highly elastic nickel-titanium files. Nickel-titanium files Precise, fast and efficient preparation of the root canal with 360° rotation. Shortened file shafts They reduce the overall working height and simplify access, particularly to the posterior region of the oral cavity. Extremely small head Endea, with its extremely small head, offers even better...

Open the catalog to page 13
Endodontics - 14

Battery type: Battery voltage: Rated capacity: Speed at root canal instrument: Torque stages: Transmission ratio: Coupling system: Recommended root canal instruments Files for rotary root canal preparation at 300 min-1 with a shaft diameter of 2.35 mm thermo washer disinfectable / sterilizable Charging station Permissible voltage fluctuation: ±10 %

Open the catalog to page 14
Endodontics - 15

Endea Endo Cursor Transmission ratio: Recommended root canal instruments: Hand root canal instruments Ø 3.6 – 4 mm 6.000 min-1 Max. motor speed: Connection diameter: Coupling system: 20 mm Motors with ISO connection according to ISO 3964 (DIN 13.940) Transmission ratio: Recommended root canal instruments according to EN ISO 1797-1:1995: Connection diameter: Coupling system: Nickel-titanium files, suitable for 360° rotation, shaft diameter 2.35 mm (type 1) 20 mm Motors with ISO connection according to ISO 3964 (DIN 13.940) Endo NiTi Type: Transmission ratio: Recommended root canal...

Open the catalog to page 15
Endodontics - 16

Pictures are for illustrative purposes only. Additional equipment and accessories shown are not included as standard. Scan the QR code with your mobile phone for more information about our products W&H Dentalwerk Bürmoos GmbH Ignaz-Glaser-Straße 53, Postfach 1 5111 Bürmoos, Austria t + 43 6274 6236-0 f + 43 6274 6236-55 office@wh.com wh.com 20381 AEN Rev. 003 / 02.02.2016 Subject to alterations

Open the catalog to page 16

All W&H Dentalwerk International catalogs and technical brochures

  1. Lyla

    7 Pages

  2. RC Series

    2 Pages

  3. RC-Sets

    2 Pages

  4. Lexa

    5 Pages

  5. Proxeo Aura

    6 Pages

  6. Implantmed

    7 Pages

  7. piezomed

    5 Pages

  8. Lisa

    7 Pages

Archived catalogs