MR5501 MR Conditional Adjustable Height Patient Trolley
15Pages

{{requestButtons}}

Catalog excerpts

MR5501 MR Conditional Adjustable Height Patient Trolley - 1

MR5501 MR Conditional Adjustable Height Patient Trolley OPERATORS MANUAL

Open the catalog to page 1
MR5501 MR Conditional Adjustable Height Patient Trolley - 2

Introduction Thank you for purchasing this MR Conditional product. Manufactured and tested to the highest standards it is guaranteed MR Conditional to 7.0T. Our products are manufactured by Wardray Premise Ltd to BS EN ISO 13485:2016 and are CE marked. Manufacturing address: Wardray Premise Limited, Northern Regional Office, Unit 2, Springvale Works, Elland Road, Brighouse, West Yorkshire, HD6 2RN, UK To ensure that you obtain maximum benefit from your product, please take a few minutes to read the enclosed information regarding operation, service and maintenance. If you have any problems...

Open the catalog to page 2
MR5501 MR Conditional Adjustable Height Patient Trolley - 3

Safety Definitions for MRI as Defined by International Standard F2503-13 MR SAFE: An item that poses no known hazards resulting from exposure to any MR environment. MR SAFE items are composed of materials that are electrically non-conductive, non-metallic, and non-magnetic. MR CONDITIONAL: An item with demonstrated safety in the MR environment within defined conditions. At a minimum, address the conditions of the static magnetic field, the switched gradient magnetic field and the radiofrequency fields. Additional conditions, including specific configurations of the item, may be required....

Open the catalog to page 3
MR5501 MR Conditional Adjustable Height Patient Trolley - 4

Specification The MR5501 Trolley is designed to be MR Conditional and is manufactured and tested to the highest standards. The MR5501 is constructed from 3 main materials, these being aluminium, brass and 316 stainless steel. The Top Frame, Pivot Sections, X Frames and Base Frame are all manufactured from aluminium, which whilst being MR compatible is also lightweight, this aids the easy movement of the trolley. Brass and stainless steel materials are used in the manufacture of the Pivot Bolts and parts within the Hydraulic Pump and Cylinder. It is advisable that the product is inspected...

Open the catalog to page 4
MR5501 MR Conditional Adjustable Height Patient Trolley - 5

MR5501 Trolley parts reference Backrest Serial Number under backrest Backrest gas cylinder Handle to operate backrest Trendelenburg position Cot sides Corner buffers Push bar Plunger Head end Pinch points IV Pole (stored on left of head) Brake Lever Castor (Optional Directional Locking Castor see page 9) Pull Handle for Trendelenburg action Thumb screw for IV Pole 5

Open the catalog to page 5
MR5501 MR Conditional Adjustable Height Patient Trolley - 6

Operating Instructions Raising and Lowering Trolley There is a pedal located each side of the trolley. To raise the trolley place your foot on the black rubber (Fig.1) and push down until you feel it stop, lift foot and allow the pedal to raise until it stops, repeat until desired height is reached, or top height is achieved (Fig 2). To lower, place foot on black rubber and push down until you feel the stop, then push further and table top will lower (Fig 3). Remove foot when table reaches desired height or lowest position is achieved. Please note the trolley is fitted with a safety...

Open the catalog to page 6
MR5501 MR Conditional Adjustable Height Patient Trolley - 7

Operating Instructions Trendelenburg The Trendelenburg can be operated easily by placing your hands on the push bar, at the head end, and pulling the handle up towards you with your fingers as shown (Fig 1) Push the top down to the desired angle (Maximum of 13 degrees - Fig 2) and release handle. To bring the top to a horizontal position, pull the handle which will then return the top to the horizontal position. Please note:- when returning to the horizontal position, the upward movement is power assisted. Backrest The backrest is operated by squeezing the handle located under the right...

Open the catalog to page 7
MR5501 MR Conditional Adjustable Height Patient Trolley - 8

Operating Instructions Cot Sides The trolley is fitted with raise and lower cot sides (Fig 1) these protect the patient during transportation to and from the ward. The cot sides should not be used to steer/ push the trolley. When lowering cot sides ensure nothing can become trapped between the cot sides and or the bed. Depending on the design of the trolley, it will be fitted with one or other of the plungers indicated below; Standard Plunger (Fig 2) or Flag Plunger (Fig 4) Standard Plunger To operate the Standard Plunger: To lower the cot sides, pull the black plunger to disengage (Fig 3)...

Open the catalog to page 8
MR5501 MR Conditional Adjustable Height Patient Trolley - 9

Operating Instructions Castors Press down firmly to lock Press down firmly to release The trolley is fitted with four 150mm diameter, individually braked castors. To engage the brakes, place your foot on the front part of the brake lever (Fig 1) and push down firmly, the brake will lock in place and stop the castor from moving. To release the brake place your foot on the rear part of the brake lever (Fig 2) and press down firmly, this will release the brake. If your trolley is fitted with a Directional Locking Castor, this is denoted by the green locking lever. To engage a directional...

Open the catalog to page 9
MR5501 MR Conditional Adjustable Height Patient Trolley - 10

Operating Instructions Oxygen Cylinder Holder An Oxygen Cylinder holder is also optional, suitable for a size E cylinder, it is usually fitted on the right hand side of the base (Fig 1). WARNING: THE OPERATOR MUST ENSURE THE OXYGEN CYLINDER IS SAFE TO USE IN YOUR MR ENVIRONMENT

Open the catalog to page 10
MR5501 MR Conditional Adjustable Height Patient Trolley - 11

Operating Instructions IV Pole The trolley is fitted with 4 locations for the IV pole,1 located at each corner of the trolley. A thumb screw allows the pole, both to be locked vertically for use, and horizontally for storage as shown (Fig 1 and Fig 2). The IV Pole is manufactured from 316 stainless steel, and is stamped with the serial No. of the trolley. IMPORTANT NOTE: As a safety precaution, please check the serial No. of the IV Pole matches the trolley’s serial No. before using.

Open the catalog to page 11
MR5501 MR Conditional Adjustable Height Patient Trolley - 12

Do’s and Dont’s Do ensure the following are observed:  The trolley should only be used by properly trained staff at all times. The trolley must be operated by 2 people when transporting a patient. When a patient is on board, the cot sides must be in an upright locked position before moving the trolley or adjusting the trolley height. The trolley must only be used for the purpose for which it was designed. Lift the trolley upwards by the top Push the trolley over rough or uneven ground Drop heavy or sharp objects onto the solid plastic top Push the trolley by the cot sides, these are for...

Open the catalog to page 12
MR5501 MR Conditional Adjustable Height Patient Trolley - 13

General Maintenance It is strongly recommended that the following checks are carried out on a weekly basis by trained personnel, to ensure trouble free operation of the trolley.  Check the solid plastic top for cracks or other obvious signs of damage or contamination. Report any damage found. Check mattress for any sign of damage or contamination. Report damage or clean where necessary with mild soap and water. Check castors for free movement and the braking mechanism for functionality, check and remove any debris that may have been caught between the forks and around the axles. This is a...

Open the catalog to page 13