
Group: Waston medical

Catalog excerpts

PROFESSIONAL RELIABLE ANKLE CATALOGUE
Open the catalog to page 1
Introduction Changzhou Waston Medical Appliance Co., Ltd, which is one of China's most dynamic and innovative surgical medical device manufacturers and service providers,was founded in 2002. It consists of five divisions, including the Orthopedics Department, Surgical Stapler Department, Thoracic Surgery Department, Surgical Instruments Department and New Product Development Department. Our company has three R&D and production bases, they are National Changzhou Hi-tech Industry Zone of Jiangsu, National Wujin Hi-tech Industry Zone of Jiangsu, and Science and Technology Center of Changzhou...
Open the catalog to page 2
Distal First Metatarsal Osteotomy Plate 1. After-osteotomy anatomic design is good for reduction, and no need to pre-bend the plate during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early functional exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. Product NO. 108.00.006 108.00.206 108.00.406 108.00.106 108.00.306 108.00.506 Specifications Left Left Left Right Right Right Description of screw: 2.7mm and 3.0mm screws are available according to patient's...
Open the catalog to page 4
Metatarsophalangeal Joint Fusion Plate I 1. Anatomic design, 9 ° dorsal flexure, and 11 ° extorsion, to avoid effect on the plate strength while it is bended during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. Product NO. 108.01.005 108.01.205 108.01.006 108.01.105 108.01.305 108.01.106 Specifications Left Left...
Open the catalog to page 5
Metatarsophalangeal Joint Fusion Plate II 1. Anatomic design, 9 ° dorsal flexure,and 11 ° extorsion, to avoid effect on the plate strength while it is bended during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. Product NO. 108.02.004 108.02.104 Specifications Left Right Description of screw: 2.7mm and 3.0mm...
Open the catalog to page 6
Hollow Metatarsal Osteotomy Plate 1. Anatomic design is good for after-osteotomy reduction, and no need to pre-bend the plate during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Hole for bone grafting is reserved on the plate, and this design facilitates the bone grafting surgery after osteotomy. 4. Design with high-strength is beneficial for the early functional exercise. 5 . S m a r t d e s i g n o f t h e e d ge re d u ce s s o f t t i s s u e irritation;thickness of the plate is 1.5mm. Product NO. 108.04.005 108.04.105 Specifications Left Right...
Open the catalog to page 7
Hollow Cuboid Osteotomy Plate 1. Cuboid anatomic design is good for after-osteotomy reduction, and no need to pre-bend the plate during surgery. 2.Plate and screw are designed based on curvature of human anatomy. 3. Hole for bone grafting is reserved on the plate, and this design facilitates the bone grafting surgery after osteotomy. 4. Design with high-strength is beneficial for the early functional exercise. 5. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.8mm. Product NO. 108.05.005 Specifications Standard Description of screw: 2.7mm and 3.0mm...
Open the catalog to page 8
Metatarsal Cuneiform Joint Dorsal Plate 1. Anatomic design is good for reduction, and no need to pre-bend the plate during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. Product NO. 108.06.004 Specifications Standard Description of screw: 2.7mm and 3.0mm screws are available according to patient's bone quality. Universal design of the screw hole...
Open the catalog to page 9
The First Metatarsal Cuneiform Joint Medial Plate 1. Anatomic design is good for reduction, and no need to pre-bend the plate during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. Product NO. 108.07.005 108.07.006 Specifications Small Large Description of screw: 2.7mm and 3.0mm screws are available according to...
Open the catalog to page 10
The Second Metatarsal Cuneiform Joint Dorsal Plate 1. Anatomic design is good for reduction, and no need to pre-bend the plate during surgery. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. Product NO. 108.08.006 108.08.007 108.08.207 108.08.008 108.08.106 108.08.107 108.08.307 108.08.108 Specifications Left Description of...
Open the catalog to page 11
Lisfrance Fusion Plate 1. Anatomic design is good for reduction, and no need to pre-bend the plate during surgery to avoid effect on the plate strength when it’s bended. 2. Plate and screw are designed based on curvature of human anatomy. 3. Design with high-strength is beneficial for the early passive exercise. 4. Smart design of the edge reduces soft tissue irritation; thickness of the plate is 1.5mm. 5. Screw cap is lower than the plate, and that reduces the soft tissue irritation. 6. Multi-articular surface fusion system facilitates the anatomic rebuilding arches of the foot. Product...
Open the catalog to page 12All Waston medical catalogs and technical brochures
-
Sternalink™
14 Pages
-
APEX BALLOON
20 Pages
-
APEX-T, APEX-L
20 Pages
-
Claw Sternum Plate
4 Pages
-
Neptuno II
8 Pages
-
1500599900
2 Pages
-
1500188800
2 Pages
-
10603 GAMMA
2 Pages
-
X Series and X series (L/R)
2 Pages
-
INTRAMEDULLARY NAIL SYSTEM
9 Pages
-
clavicle
5 Pages
-
Linear surgical stapler FHY
1 Pages
-
Linear surgical stapler ZHY
1 Pages
-
Curved surgical stapler HQY
1 Pages
-
Linear surgical stapler QHD
1 Pages
-
trocar CCQ and HFY and HBQ
1 Pages
-
ulna & radius
12 Pages
-
humerus
6 Pages