PROFESSIONAL RELIABLE TRAUMA CATALOGUE
Open the catalog to page 1Humerus Locking Plate Used for humeral shaft fracture. Screw: 10751 3.5 Locking Screw / 10503 3.5 Cortical Screw Instrument Set: 15001-888 Small Bone Fragment Instrument Set Distal Medial Humeral Locking Plate Used for distal medial humeral fracture, supracondylar fracture of humerus and nonunions of humeral fracture Screw: Head Part 10960 2.7 Self-tapping Locking Screw (20° ) Shaft Part 10751 3.5 Locking Screw 10503 3.5 Cortical Screw 10520,10521 HB4.0 Cancellous Screw Instrument Set: 15001-888 Small Bone Fragment Instrument Set
Open the catalog to page 2Locking Plate System Proximal Humeral Locking Plate II Used for proximal humeral fracture. Screw: 10751 3.5 Locking screw / 10503 3.5 Cortical Screw 10520,10521 HB4.0 Cancellous Screw Instrument Set: 15001-888 Small Bone Fragment Instrument Set Proximal Humeral Locking Plate III Used for proximal lateral humeral fracture. Screw: 10751 3.5 Locking Screw / 10503 3.5 Cortical Screw 10520,10521 4.0 Cancellous Screw Instrument Set: 15001-888 Small Bone Fragment Instrument Set
Open the catalog to page 3Locking Plate System Distal Lateral Humeral Locking Plate I Used for distal humeral fracture, supracondylar fracture of humerus and nonunions of humeral fracture Screw: Head part 10960 2.7 Self-tapping Locking Screw (20° ) Shaft part 10751 3.5 Locking Screw / 10503 3.5 Cortical Screw 10520,10521 HB4.0 Cancellous Screw Instrument Set: 15001-888 Small Bone Fragment Instrument Set Distal lateral humeral Locking Plate II Used for distal humeral fracture, supracondylar fracture of humerus and nonunions of humeral fracture Screw: Head part 10960 2.7 Self-tapping Locking screw (20° ) Shaft part 10751...
Open the catalog to page 4HA2.7 Locking Screw (20° , Self-tapping, Torx) HA3.5 / HA5.0 Locking Screw (Self-tapping,Torx) Length(mm) 10-48(In 2mm increments) 50-60(In 5mm increments) Length(mm) 12-42(2mm increments) 45-60(5mm increments) 14-50(2mm increments) 55-70(5mm increments) 75-110(5mm increments) Cancellous Screw (Fully threaded / Half-threaded) Note: L2=threaded part length
Open the catalog to page 5More Professional More Effective Your Reliable Waston Changzhou Waston Medical Appliance Co.,Ltd 9Xihu Road,Wujin Hi-Tech Industry Zone, Jiangsu Province,China TEL:+86-519-89888852 Email:[email protected] www.wastonmed.com