Force NC
8Pages

{{requestButtons}}

Catalog excerpts

Force NC - 3

PTCA NC Balloon Catheter FORCE NC, the high pressure PTCA catheter that ensures pressure when pressure is needed without compromising on flexibility, profile and catheter performance. Now get the highest rated burst pressure on the market with superb catheter performances that enables precise and safe post dilatation. Excellent re-wrap and re-cross

Open the catalog to page 3
Force NC - 4

THE FIRST LOW PROFILE, FLEXIBLE HIGH PRESSURE Highest rated burst pressure available - Rated burst pressure 24 bar, nominal pressure 12 bar - Providing an extensive and safe working range - No longitudinal growth for controlled expansion, even at high pressures - No balloon deformations up to rated burst pressure for precise stent apposition - No dog boning between nominal and rated burst pressure Unsurpassed flexibility and low profile Optimized materials and design for unsurpassed flexibility and low profiles Ease of use equal to high performance workhorse catheters Lesion entry profile...

Open the catalog to page 4
Force NC - 5

Real non compliant - Real non compliant: less than 1% growth per atmosphere between nominal and rated burst pressure - Controlled equal growth during inflation up to rated burst pressure - Precise compliance ensuring exact and protected sizing Newest generation hydrophilic coating - Fully coated, tip to distal shaft including folded balloon - Eliminates catheter friction, prevents release of particles - Remains durable during multiple inflations FORCE NC balloon Quantum Maverick balloon NC Sprinter balloon nom. 12 atm/RBP 24 atm. nom. 12 atm/RBP 20 atm. nom. 10 atm/RBP 18 atm.

Open the catalog to page 5
Force NC - 6

BALLOON CATHETER COMPLIANCE CHART NP: Nominal Pressure RBP: Rated Burst Pressure. Do not exceed * Max. recommended inflation pressure

Open the catalog to page 6
Force NC - 7

Nominal Pressure: Rated Burst Pressure: Balloon material: Folding: Guiding catheter compatibility: Guide wire compatibility: Catheter type: Proximal shaft: Distal shaft: Lesion entry profile: Usable Catheter Length: Deflation time: Tapered tip: Shaft coating: Shelf life: 12 bar 24-22 bar Non-compliant polyamide for controlled dimensions 3-folds 5F (min ID 0.056”/1.42 mm) max 0.014” (0.36 mm) Rapid Exchange 1.9F (0.64 mm) 2.7F (0.90 mm) 0.016” (0.40 mm) 154 cm 4 seconds (0 3.0, L: 20) 3 mm Hydrophilic coating 3 Years from sterilization date

Open the catalog to page 7
Force NC - 8

Order number description: XFOR DDLL (D=Diameter, L=Length) bluemeoical BLUE MEDIC AL DEVICES B.V., PAOOVEWWEG 7, 5708 HR HELMOND, THE NETHERLANDS PHONE: +31 (0)492 58 89 00, FAX: +31 (0)492 5E 89 09, E-MAIL: CS@BLUEMEDICAL.COM,WWW.BLUEMEDICAL.COM Indications, contraindications, wardi ngs and instructiou foruse can be found inthe nroduct labeling. CAUTION: restricted to sale by or on the order of a physician