Primum
1 /1Page

Primum

Primum
1 /1Page

Catalog excerpts

Primum-1

Ordering information ...even challenging cases will look easy from now on UFT Hydrophilic coating providing new frontiers • Smooch catheter introduction • Low friction during catheter advancement in tortuous and calcified anatomy • Reduced vessel spasm in radial approach resulting in more patient comfort • Less trauma to the vessel wall reducing the risk of debris flowing downstream which could lead to TIA's • The uncoated proximal 25 cm of the catheter stays outside the body which makes manipulation easier Very precise control • No stick slip effect due to Hydrophilic coating provides more accurate tip positioning in ostial lesions • The uncoated segment In the valve of the sheath prevents unintentional movement of the catheter during the procedure • No catheter friction provides real 1:1 torque control of the tip • Encapsulated ultra thin high strength flat wire braiding provides high kink resistance against torsional and radial compression and excellent pushability characteristics Largest inner lumen over the whole range • Good contrast injection, also in combination with kissing balloon technique • Larger lumens offer expanded device compatibility for large profile devices and enables downsizing 1 058'; | .071' ; I o82* ’ 091' Superior back up support • Excellent shape retention during prolonged procedure time • Minimal temperature softening of the catheter providing more passive backup support • Uncoated segment in the tip providing good grip at ostium and support of opposite aorta wall to give additional passive backup support * also available with 2 sideholn. To order ihi* Uiape with odeholei please change the 7lh number in ihe article number from 0 into 2 Guiding catheter www pcndracure.com © Ptndrrfjrc Initfruiiorul t.V SPEC Cvo)i-o? As of today hydrophilic coating the guiding catheter will change landscape... shape selector Guiding catheter selection considerations FEMORAL small I normal I dilated ■ small Wear resistant hydrophilic coating approx. 7cm proximal from the tip until 25 cm distal from the hub ftftft ftftft Extra back up shapes Amptatz shapes OTHER TAKE-OFFS Uf* EALING I DOWNWARD I FACING ftftft ftftft The guiding catheter is the key to a successful procedure. In combination with the unique features of the PRIMUM. the selection of a guiding catheter depends on: The shape selection • Femoral or Radial approach • French size 5F. 6F. 7F or SF • Target vessel: RCA. LAD. LCX or bypass • Narrow, normal or dilated aortic root • Upward-, normal or downward facing coronary artery take-off • Location of the lesion • Severity of the lesion • Active support needed • Amount of calcium in target vessel French size • 6F is the workhorse and the majority cases can be successfully performed with a 6F. • 5F mainly for radial approach with small vessel and single vessel disease • 7F when the back up support of a 6F may not be sufficient or for rotablator procedures with a Burr to 1.75 mm • SF for rotablator procedures with a Burr bigger than 1.75mm Extra back up shapes ftftft ftftft Ampiatz shapes Small a traumatic softtip Superior shape retention and back up support Low friction in tortuous and calci

 Open the catalog to page 1

All Wellinq catalogs and technical brochures

  1. Force NC

    8  Pages

  2. Summit

    8  Pages

  3. Pointer

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.