Protégé/Protégé NC
1 / 12Pages

Catalog excerpts

Protégé/Protégé NC - 3

Drug eluting balloon catheter Only innovations based on scientific evidence create the level of confidence required to transfer optimal treatment methods to higher quality of life. Blue Medical has developed a drug eluting balloon that opens a window of opportunities with regard to treating coronary diseases. Supported by independent scientific evidence, we offer a safe, effective and reliable tool to further enhance patient care with accurate local drug delivery. With Protégé NC, the non compliant DEB, safe and reproducible drug delivery is now combined with the proven treatment advantages...

Open the catalog to page 3
Protégé/Protégé NC - 4

Safe and reproducible drug delivery - Drug incorporated in hydrophilic coating - No airborne particles at any time and no premature release of Paclitaxel - Paclitaxel is only released when the balloon touches the vessel wall - Hydrophilic coating delivers Paclitaxel homogeneous to the vessel wall instantaneously upon contact - Paclitaxel is rapidly and maximally absorbed by the vessel wall - Minimized drug content in contact with operator - Minimized drug loss in bloodstream prior to inflation securing reliable drug dose delivery - Load secured to achieve the therapeutic window within 30...

Open the catalog to page 4
Protégé/Protégé NC - 5

No procedural limitations - No change in standard operating procedures or handling required - No pre-dilatation required: tight lesion crossing does not influence drug delivery - Multiple inflations will not lead to toxic levels - Therapeutic window achieved after 30 seconds inflation time - Flexibility and characteristics of a normal workhorse PTCA balloon Proven balloon platform - Based on Blue Medical’s proven high-end PTCA catheters Everest and Force - Incorporated latest insights on re-folding and re-wrap interactions - Technology optimized to reach and cross the most difficult lesions...

Open the catalog to page 5
Protégé/Protégé NC - 6

DRUG DELIVERY NOW COMBINED Non compliant PTCA balloons are commonly used to post-dilatate stents or to treat in stent restenosis (ISR). With the introduction of Drug Eluting Balloons medication was added to PTCA balloon treatment. But the need for precise and powerful dilatation remained. With Protégé NC we succeeded in combining safe and reproducible drug delivery with the proven treatment advantages of a non compliant balloon. Thus reducing procedural costs and post procedural medication requirements and at the same time increasing procedure efficiency, safety and patients comfort. In...

Open the catalog to page 6
Protégé/Protégé NC - 7

WITH PRECISE POWERFUL DIL ATATION High rated burst pressure - Rated burst pressure 24 bar, nominal pressure 12 bar - Providing an extensive and safe working range Real non compliant - No longitudinal growth for controlled expansion, even at high pressures - No balloon deformations up to rated burst pressure for precise stent apposition - No dog boning between nominal and rated burst pressure - Presice compliance ensuring exact and protected sizing No compromise on flexibility and profile - Optimized materials and design for unsurpassed flexibility and low profiles - Ease of use equal to...

Open the catalog to page 7
Protégé/Protégé NC - 8

NP: Nominal Pressure RBP: Rated Burst Pressure. Do not exceed

Open the catalog to page 8
Protégé/Protégé NC - 9

Nominal Pressure: Rated Burst Pressure: Balloon material: Folding: Drug: Guiding catheter compatibility: Guide wire compatibility: Catheter type: Proximal shaft: Distal shaft: Lesion entry profile: Usable Catheter Length: Average deflation time: Tapered tip: Catheter coating: For additional details please refer to our website www.bluemedical.com.

Open the catalog to page 9
Protégé/Protégé NC - 10

NP: Nominal Pressure RBP: Rated Burst Pressure. Do not exceed * Max. recommended inflation pressure

Open the catalog to page 10
Protégé/Protégé NC - 11

Nominal Pressure: Rated Burst Pressure: TECHNICAL DATA Protege non compliant DEB Balloon material: Folding: Drug: Guiding catheter compatibility: Guide wire compatibility: Catheter type: Proximal shaft: Distal shaft: Lesion entry profile: Usable Catheter Length: Average deflation time: Tapered tip: Catheter coating: For additional details please refer to our website www.bluemedical.com.

Open the catalog to page 11
Protégé/Protégé NC - 12

ORDER NUMBERS Order number description: PNC DDLL / PRO DDLL (D=Diameter, L=Length) BLUE MEDICAL DEVICES B.V., PANOVENWEG 7, 5708 HR HELMOND, THE NETHERLANDS PHONE: +31 (0)492 58 89 00, FAX: +31 (0)492 58 89 09, E-MAIL: CS@BLUEMEDICAL.COM, WWW.BLUEMEDICAL.COM Indications, contraindications, warnings and instruction for use can be found in the product labeling. CAUTION: restricted to sale by or on the order of a physician PRO9.0001.04 02/2015

Open the catalog to page 12