PRAXIS 2 ELITE USER’S MANUAL AND MAINTENANCE GUIDE

Open the catalog to page 1
PRAXIS 2 ELITE - 2

General information Manufacturer Equipment intended use and description storage Symbols Special warnings and use restrictions Use en setting up accessories Cleaning and conservation Maintenance Preventive maintenance Corrective maintenance Spare parts Troubleshooting Technical data sheet Warranty Service record Starting up Setting up and adjustment Transportation and brakes 1. GENERAL INFORMATION MANUFACTURER Wesseling BV, Venenweg 31, 1161 AK Zwanenburg, Netherlands-Tel.+31 204975183-Fax+31 204975909 – website:www.wesseling-bv.com EQUIPMENT INTENDED USE AND DESCRIPTION The Praxis tables...

Open the catalog to page 2
PRAXIS 2 ELITE - 3

2. SPECIAL WARNINGS AND USE RESTRICTIONS Equipment must not be used:  Without knowing the user’s manual.  When the safety load exceeds the stated capacity.  Without the patient being monitored.  When the patient and/or equipment is not stable enough.  When table is not on its feet when stopped, during treatment, or when patient is moved to/from other equipment.  When the original product has been tampered with and/or modified from its original configuration.  When the controls and/or components are even only partially faulty or defective.  When incorrectly configured or when you...

Open the catalog to page 3
PRAXIS 2 ELITE - 4

14-5-2018 A hydraulic table is equipped with a hydraulic pump with foot pedals on both sides of the table. The height adjustment by means of the pappels: Up:  Push down the pedals with your foot by pressing the designated footpath. Repeat until the desired height is reached. Down:  Push up the pedals with your foot by pushing the designated footpath. Keep pushing until the desired height is reached. To adjust the back section pull the control handle, and support the section as it moves. Release the handle to secure the position. The control handles are on both sides of the table. With the...

Open the catalog to page 4
PRAXIS 2 ELITE - 5

4. USE AND SETTING UP OPTIONS With the use of the optional accessories this table can be used for multiple treatments. The paper holder is always mounted on the head-section of the Praxis. The maximum roll width that fits into holder 60cm. PAPRAX: Paper roll holder Praxis Placing a roll of paper:  Turn the knob and pull the rod out of the holder.  Place the paper roll in the holder and push through the rod.  Tighten the knob to hold the rod in place. The adapters are supplied per set and assembled for delivery to the table. The adapters are rotatable and can be positioned in every...

Open the catalog to page 5
PRAXIS 2 ELITE - 6

14-5-2018 The stir-ups are supplied per set and will be delivered with the table. In combination with the rotatable adapters they can be positioned in every desired position. The height of the this support can be adjusted as follows: Turn the black knob and fit the support to the desired height. Then tighten the knob again to maintain this height. With the weight of the patient on the support, loosen the knob only if you are sure that the whole weight is supported. The leg-/knee supports are supplied per set and will be delivered with the table. Due to the bend in the chromed bar this...

Open the catalog to page 6
PRAXIS 2 ELITE - 7

14-5-2018 By choosing to barswitch-system the standard switch will not be on the table. By pushing the bars which are located on both sides of the table, you can adjust the height of the table. Adjusting the height:  Push down one of the bars to let the table go down. Stop pushing when you have reached the desired height.  Push up one of the bars to let the table go up. Stop pushing when you have reached the desired height. Standard the table is mounted with one switch of choice. We can equip the table with multiple switches. If you choose for an extra hand switch, you also need a link to...

Open the catalog to page 7
PRAXIS 2 ELITE - 8

14-5-2018 The standard parts are filled with polyether and are about 55mm thick. When the optional Lazy Foam is chosen the total thickness is 70mm. The upholstered sections will not only be thicker but also softer and therefore more comfortable for patients who need to be longer on the table. LAZYFOAM: memory foam This neck pillow ensures that the patient can sit/lie comfortably. The cushion has an elastic strap on the rear with Velcro closure. This is to position the cushion at almost every place. The cushion has a size of 58x18x9cm. The cover on the back is also equipped with a zipper and...

Open the catalog to page 8
PRAXIS 2 ELITE - 9

6. MAINTENANCE Maintenance operations must be carried out by technicians who are familiar with the contents of this instruction booklet. Check the equipment is safe after any instances of "rough handling" (e.g. fall, bumps, etc.) and any time you are in doubt about safety. ROUTINE MAINTENANCE Routine maintenance operations must be carried out with the frequency indicated in the table. General equipment cleaning. Visual and functional inspection of the equipment and related hydraulic and manual controls. Frame and mechanical parts: Check screws and bolts are tight; state of wear of bushings...

Open the catalog to page 9
PRAXIS 2 ELITE - 10

14-5-2018 If the equipment fails to operate, please follow the troubleshooting process below. Issue Adjustment of the head-/back section doesn’t work or the position is not maintained One of the actuators does not work Cause Gas spring faulty or incorrectly set Transmission cable damaged or broken Solution Contact Wesseling BV The attached switch is broken or not connected properly Power cable is damaged or not connected properly Actuator is damaged or not connected properly 8. TECHNICAL DATA SHEET Product Name Product Code Safe working load Max patient weight Height adjustment Adjustment...

Open the catalog to page 10
PRAXIS 2 ELITE - 11

14-5-2018 GENERAL AFTER-SALES SERVICE CONDITIONS FOR WESSELING ITEMS The warranty has a 24-month validity from the date of delivery. The warranty does not cover consumable items, rechargeable batteries, and generally all the material subject to wear, breakdowns caused by knocks, falls, misuse or improper use, accidental events and transport damage. This warranty shall be automatically invalidated if the equipment is tampered with. Repair of the equipment will be carried out in relation to the breakdown stated. An estimate must be specifically requested. Payment is cash on delivery, unless...

Open the catalog to page 11