Ceramotherm® 3000
16Pages

{{requestButtons}}

Catalog excerpts

Ceramotherm® 3000 - 1

Baby changing, Examination, Intensive care  One radiant warmer for all applications  Baby changing, Examination, Intensive care Convenient, safe, reliable

Open the catalog to page 1
Ceramotherm® 3000 - 2

Sensible cosy and gentle warming In various situations patients need support to maintain their body temperature. This applies to unclothed babies during nappy changing, infants under longer examination, centralized patients and theatre preparation and recovery. Infrared radiant warmers are ideal for this purpose. But which is the right one? Infra-red radiation is part of the solar spectrum and invisible for human beings. It is devided in three ranges according to their wave-length. CERAMOTHERM CERAMOTHERM Wave length µm Wave length µm Callus Callus Epidermis Epidermis Wave length µm Wave...

Open the catalog to page 2
Ceramotherm® 3000 - 3

The radiant warmer Radiant Warmers CERAMOTHERM are the result of nearly 40 years of continuous development in the medical use of infrared radiation. Convenient handling and function, comfortable operation as well as a safe use are the priorities of this radiant warmer. Intensity display in mW/cm² Integrated timers Ceramic heating elements Adjusting knob Dazzle-free illumination Finger touch protection Convenient, safe, reliable

Open the catalog to page 3
Ceramotherm® 3000 - 4

Impressive warming efficiency Quick-Heat function Infrared rays do not warm-up the ambient air but are absorbed by the bodies they impinge on and are so converted into heat. By the new developed high-performance reflector the heat is directed to the patient pad even more efficiently and evenly. The Quick-Heat function produces the required warming energy within shortest time and outshines conventional radiant heaters. Weyer CERAMOTHERM 3100 Conventional radiant warmer Alarm reset Multi-functional display Adjusting knob Easy to operate Same as the well-proven product series THERMOCARE and...

Open the catalog to page 4
Ceramotherm® 3000 - 5

Homogeneous illumination CERAMOTHERM APGAR For the smallest patients the best light is just good enough. Infants, in particular new born babies, are stressed when they are dazzled by a sudden glaring spot-light. Therefore the large-area lamps of the CERAMOTHERM 3000 switch on and off the light gently. Small patients remain calm and feel cosy. The colour temperature of the light is 4000 Kelvin which guaranties an excellent appearance and is suitable for examination and minor operations. The illumination intensity can be adapted in 5 steps according to the actual situation. So the optimum...

Open the catalog to page 5
Ceramotherm® 3000 - 6

Application with maximum safety The infrared spectrum of the radiant warmers CERAMOTHERM was chosen in a way that on one hand the patients are warmed efficiently and on the other hand it cannot cause any injuries to the eye and the skin, expert use provided. Very small or hypothermic patients often require high radiation intensity to maintain their body temperature. In most cases this is above 10 mW/cm² which in the long run can cause hyperthermia and skin injuries. In order to avoid such hazards after a certain time the radiation intensity is automatically reduced to a safe value and a...

Open the catalog to page 6
Ceramotherm® 3000 - 7

CERAMOTHERM 3100 with 1 heating element, mainly for babies during postnatal care, nappy changing and examination as well for application in the care sector. The device is also suitable for partial warming of body parts. CERAMOTHERM 3200 with 2 heating elements, covering a larger area. Safe application for pre-term infants, babies, infants and adults as well as for pre-warming of patient beds. Sensible convenient warming during care, nappy changing, examination It must be avoided that in particular unclothed new-born infants loose body heat. During postnatal care and after bathing there is a...

Open the catalog to page 7
Ceramotherm® 3000 - 8

CERAMOTHERM 3000 Warming - wherever it is required ® Wide range of fixtures Radiant warmers CERAMOTHERM 3000 can be mounted at the wall, the ceiling or a mobile stand. Keeping in mind the intended use and constructional conditions a wide range of fixtures can be chosen for the individual application. Static arrangement to the patient pad 1 1 2 Ceiling bracket, distance between patient pad and bottom edge of solid ceiling max. 2600 mm CERAMOTHERM 3100 Order No. WY3117 CERAMOTHERM 3200 Order No. WY3217 In case of larger distance to the solid ceiling a connection flange B0329 is required....

Open the catalog to page 8
Ceramotherm® 3000 - 9

Swivelling wall arms For applications where it is not necessary to adjust the distance between patient pad and radiant warmer, wall arms in 3 lengths are available which can be swivelled ±90°. The radiant warmer can be rotated by 360° and locked in the desired horizontal position. As option these arms can also be equipped with vertical extension and vertical adjustment. Horizontal swivelling ±90° and lockable, warmer rotatable 360° Wall arm 320 mm length CERAMOTHERM 3100 Order No. WY3101 CERAMOTHERM 3200 Order No. WY3201 Wall arm 480 mm length CERAMOTHERM 3100 Order No. WY3102 CERAMOTHERM...

Open the catalog to page 9
Ceramotherm® 3000 - 10

Further arrangements Double-joint wall arm, R1 = 480 mm, R2 = 480 mm, Wall arm swivelling ±90° and lockable, warmer rotatable 360°, vertical adjustment ± 45° CERAMOTHERM 3100 Order No. WY3104 CERAMOTHERM 3200 Order No. WY3204 Option: R1 = 320 or 600 mm R2 = 320 or 600 mm 8 Ceiling bracket, distance between patient pad and bottom edge of solid ceiling max. 2600 mm CERAMOTHERM 3100 Order No. WY3117 CERAMOTHERM 3200 Order No. WY3217 In case of larger distance to the solid ceiling a connection flange B0329 is required. Refer to mounting information on page 14. Height-adjustable double-joint...

Open the catalog to page 10
Ceramotherm® 3000 - 11

For each field the right solution A variety of components are available for realizing special solutions. A combination of examination light or phototherapy device with a radiant warmer is possible as well as a combination of radiant warmers for a central baby-changing area. Flexible - heat everywhere Radiant warmers often need to be arranged completely flexible, either to allow the patient the required elbow room or to warm certain body parts or to swivel them into parking position after use. For mobile nursing beds or height-adjustable examination stretchers in most cases a radiant warmer...

Open the catalog to page 11

All Weyer catalogs and technical brochures

  1. VARIOTHERM®

    8 Pages

  2. EASY CARE

    4 Pages

  3. THERMOCARE

    8 Pages

  4. CERAMOTHERM

    16 Pages

Archived catalogs

  1. Thermocare

    2 Pages

  2. VARIOTHERM

    8 Pages

  3. MINIVAC