Treatment & Care
8Pages

{{requestButtons}}

Catalog excerpts

Treatment & Care - 1

VARIOTHERM Warming is life Resuscitation Intensive care Warming therapy Phototherapy VARIOTHERM THERMOCARE

Open the catalog to page 1
Treatment & Care - 2

It is most important for all new born and preterm infants to have a warm and cosy environment and as much contact with their parents as possible. The infant care systems Variotherm and Thermocare have been specifically designed for these conditions, allowing full access for the necessary diagnostic, therapeutic and nursing procedures to be carried out. resuscitation unit in the delivery room or operation theatre as well as for intensive care of small preterm infants. VARIOTHERM devices have low perspex walls and are intended to be used as open care systems whereas THERMOCARE devices are...

Open the catalog to page 2
Treatment & Care - 3

The comfortable conductive under-pad heating device with anti-decubitus gel pad warms up even hypothermic infants quickly and efficiently. The standard temperature selection range of 35° to 37° can be increased via safety lock to 30° to 38.5°. Selected and actual temperature are displayed as well as the residual heat when the device is switched-off. Alarms are provided for high and low temperature, system faults and power failure. A separate safety circuit switches off the heating in the case of fault. Temperature selection Temperature display For resuscitation and intensive care it is...

Open the catalog to page 3
Treatment & Care - 4

The base devices Warming bed with conductive under-pad heating device for the warming care of infants. Oxygen therapy is possible by supplying oxygen into the interior at a concentration of 40 % or via oxygen headbox. THERMOCARE K Order No. WY2030 Electrically powered height-adjustment 4 fold-down perspex walls 250 mm high 1 perspex canopy 2 perspex safety side walls, retractable into the bassinet 1 instrument and monitor shelf at the rearside of the device 4 take-off sockets 230 V for connecting additional devices Order No. WY2030 Infant care system with conductive under-pad heating device...

Open the catalog to page 4
Treatment & Care - 5

Upgrade items and accessories Order No. WY2060 WY2061 WY2067 WY2068 WY2075 WY2062 WY2065 WY2063 WY1003 WY1004 Upgrade of base devices For all base devices Shelf for the trolley with raised sides and instrument rail 25 x 10 mm at the front-end, or optionally: Drawer unit for the trolley with 2 drawers, top designed as shelf, with raised sides and instrument rail 25 x 10 mm at the front-end. High-grade steel infusion pole Ø 25 mm, 600 mm long, fixed at the instrument and monitor shelf High-grade steel infusion pole Ø 25 mm, height-adjustable, fixed at the instrument and monitor shelf...

Open the catalog to page 5
Treatment & Care - 6

Phototherapy For treatment of the neonatal hyperbilirubinemia the phototherapy device BILI-COMPACT delivers the high-effective "Blue-BAM spectrum by 10 energy saving bulbs. By the high utilization of intensity the treatment times are shortened considerably. The device operates in complete silence and practically no heat is emitted in the direction of the patient. Therefore it can just be placed on the canopy of warming bed THERMOCARE K, order No. WY2030. It is also possible to place it on incubators with suitable canopy (up to 5° slant, load approx. 5 kg), without influencing the...

Open the catalog to page 6
Treatment & Care - 7

Technical data THERMOCARE K General data Base device Depth Width Height Weight Height adjustment, range Castors Ø 125 mm / kickstop Bumpers Ø 70 mm Patient area Depth Width Level Head up/feet down Feet down/head up Under-pad heating device Gel pad, conductive Pad, non-conductive Perspex walls, fold-down Perspex canopy Safety perspex side walls, retractable Tube assembly with radiant warmer Radiant warmer swiveling Operating and performance data Operating voltage / power supply Max. power input - without additional devices - with additional devices Take-off sockets for additional devices...

Open the catalog to page 7
Treatment & Care - 8

Technical data (continued) THERMOCARE K THERMOCARE KCE VARIOTHERM REA-KCE VARIOTHERM REA-C Colours Trolley Bassinet Radiant warmer White RAL 9002 White RAL 9010 - White RAL 9002 White RAL 9010 White RAL 9010 White RAL 9002 White RAL 9010 White RAL 9010 White RAL 9002 White RAL 9010 White RAL 9010 Classification Protection class Device type MDD class 1 B IIa 1 B IIb 1 B IIb 1 B IIa Standards EN 60601 (edition 1996) EN 60601-2-35 *, 1997-12 EN 60601-2-21**, 1995-12 resp. modification A1 1998-01 Yes Yes Yes Yes Yes Yes Yes - - Yes Yes Yes Maintenance Inspection Preventive maintenance Annual...

Open the catalog to page 8

All Weyer catalogs and technical brochures

  1. VARIOTHERM®

    8 Pages

  2. EASY CARE

    4 Pages

  3. THERMOCARE

    8 Pages

  4. CERAMOTHERM

    16 Pages

Archived catalogs

  1. Thermocare

    2 Pages

  2. VARIOTHERM

    8 Pages

  3. MINIVAC

    2 Pages