1. Catalogs
  2. WITT
  3. Flashback arrestors for propylene
video corpo

Flashback arrestors for propylene

Flashback arrestors for propylene

Flashback arrestors for propylene

Product catalog summary
Overview
WITT-GaseTechnik GmbH & Co KG manufactures safety devices for propylene service, including mixing, metering, and control equipment, as well as analyzing systems for common gases. Their Flashback Arrestors provide reliable protection against reverse gas flow and flashbacks, adhering to EN 730-1 / ISO 5175 standards.
Key Features
  • Large surface area flame arrestor made of stainless steel to extinguish flashbacks.
  • Temperature-sensitive cut-off valve to prevent sustained flashbacks.
  • Spring-loaded non-return valve to prevent reverse gas flow.
  • Filter at the gas inlet to protect against dirt contamination.
Operation and Usage
  • Used to protect gas cylinders and pipeline outlet points.
  • Suitable for high-use pipeline outlets and single cylinders.
  • Can be mounted in any position or orientation.
  • Maximum ambient/working temperature is 70°C (158°F).
Maintenance
  • Annual testing of non-return valve, body leak tightness, and flow capacity is recommended.
  • Servicing should be performed by the manufacturer, except for dirt filter replacement.
Approvals
  • Company certified according to ISO 9001 and PED 97/23/EC module H.
  • CE-marked according to PED 97/23/EC.
Technical Data
  • Models include E460, RF53N, 85-10, 85-20, and 85-30, with varying maximum working pressures and dimensions.
  • Flow diagrams provided for propylene at 20°C (68°F) with different inlet pressures.
See more

Catalog excerpts

Flashback arrestors for propylene-1

safety devices for Propylene service E460 WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to EN 730-1 / ISO 5175. Every Arrestor 100% tested. The best Flashback Arrestors in the world ●● for torches of burners: Model E460 ●● a large surface area flame arrestor FA of stainless ●● WITT Flashback Arrestors may be mounted in any steel construction extinguishes any dangerous flashback entering the device in any direction ●● a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level (not on E460) sudden reverse gas flow forming explosive mixtures in the gas supply ●● a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life (only RF53N, 85-10, 85-30) ●● Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks ●● for pipeline outlets and single cylinders with high users Technical Data 70 °C / 158 °F Maintenance ●● annual testing of the non-return valve, body leak tightness and flow capacity is recommended ●● WITT is happy to supply special test equipment ●● Flashback Arrestors are only to be serviced by the manufacturer. The dirt filter may be replaced by competent staff Operation / Usage single Flashback Arrestor ●● the maximum ambient / working temperature is Approvals Company certified according to ISO 9001 and PED 97/23/EC module H CE-marked according to: - PED 97/23/EC Length [inch] Brass Elastomer Connections available on request manufactures mixing, metering and control equipment as well as analysing systems and safety equipment for all common gases Product Information ●● a spring loaded non-return valve NV prevents slow or position /orientation ●● only one piece of equipment may be connected to a

 Open the catalog to page 1
Flashback arrestors for propylene-2

safety devices for Propylene service 35 Standard volume flow [Nm3/h] (1013 mbar / 14.7 psi, 0 °C / 32 °F) Inlet pressure: Pv [bar] Opening pressure: 30 mbar Flow diagram for propylene (20 °C / 68 °F) 65 Flow diagram for propylene (20 °C / 68 °F) Standard volume flow [Nm3/h] (1013 mbar / 14.7 psi, 0 °C / 32 °F) Inlet pressure: Pv [bar] Opening pressure: 30 mbar Standard volume flow [Nm3/h] (1013 mbar / 14.7 psi, 0 °C / 32 °F) Flow diagram for propylene (20 °C / 68 °F) Standard volume flow [Nm3/h] (1013 mbar / 14.7 psi, 0 °C / 32 °F) Flow diagram for propylene (20 °C / 68 °F) Inlet pressure: Pv...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.