1. Catalogs
  2. WITT
  3. Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2
video corpo

Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2

Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2

Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2

Product catalog summary
Overview: The document provides technical specifications and features of gas analysers manufactured by WITT-GaseTechnIk GmbH & Co KG, focusing on the PA 3 and PA 7.0 models. These analysers are designed for monitoring protective atmospheres in food packaging and welding applications.
Key Features:
  • Compact design suitable for continuous and intermittent sampling.
  • Touch panel operation with a large illuminated graphic display.
  • Interfaces include mini SD and mini USB ports for updates and data transfer.
  • Integrated data logger capable of storing the last 500 measurements.
  • Multilingual menu guide available in several languages.
  • System errors trigger alarms and can shut down machinery to prevent quality issues.
  • Splash-proof and robust housing.
Options:
  • Software obCC for result recording and data cable.
  • Separate table printer for instant documentation.
Technical Specifications:
  • Measuring systems for O2 and CO2 with various measuring cells and ranges.
  • Sample gas requirements and calibration details provided.
  • Temperature range for operation: 5 – 40 °C (41 – 104 °F).
  • Gas connections and inlet pressure specifications detailed.
  • Alarm contacts and interface options including RS 232 and analog output.
  • Housing is splash-proof with dimensions and weight specified.
  • Power options include 230 V AC, 110 V AC, or 24 V DC.
Certifications:
  • ISO 9001 and ISO 22000 certified.
  • CE-marked according to EMC 2004/108/EC and Low Voltage Directive 2006/95/EC.
  • Compliant with Regulation (EC) No 1935/2004 for food-grade gases.
See more

Catalog excerpts

Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2-1

GAs AnAlysers Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2 Compact analyser for the monitoring of protective atmospheres in food packaging (MAP) and welding. For continuous analysis (in-line) and also intermittent sampling via a needle e.g. from food packs. A flexible analyser to guarantee quality and productivity of production processes. Whenever you need a record of your measurement this instrument together with the exclusive OBCC-Software is the solution. Provide your customer with the results proving that your product has the best possible quality. Benefits ●● new operation by touch panel Spanish, Dutch, Swedish, Finish, Polish, Hungarian, Romanian and Turkish (more to come) ●● system errors or exceeding of set limits trigger an alarm and switch a potential free contact (e.g. to shut down machinery to avoid quality problems) ●● splash-proof and robust housing ●● interface for transfer of logged data ●● large illuminated graphic display Product Information ●● multilingual menu guide: German, English, French, Italian, ●● Interfaces on front: mini SD and mini USB port - update possibility - data transfer via mini USB ●● minimum sample gas required for analysing of smallest volumes (e.g. food packing) ●● fast measuring results of sampling ●● integrated data logger for the last 500 measurements ●● assignment of measurements to different product names, users and product lines Options ●● software OBCC for recording of results incl. data cable (see separate data sheet) ●● separate table printer for instant documentation Other models, options and accessories available on request. Please identify the individual gases at the time of enquiring! Measuring systems Measuring system chemical measuring cell chemical measuring cell zirconia measuring cell infrared measuring cell O2 for sampling O2 for continuous analysis Measuring range Response time Service life long lifetime long lifetime manufactures mixing, metering and control equipment as well as analysing systems and safety equipment for all common gases Technical Data

 Open the catalog to page 1
Portable Process Analyser PA 7.0 for O2, CO2 or O2/CO2-2

Finish P-version L-version S-version over pressure measurement measurement via lance with pump sample measuring O2 and/or CO2; balance gas: N2, Ar (others on request) not for flammable, corrosive or toxic gases! Measuring system simple two point calibration Withdrawal sample continuous automatic via needle using integrated pump by pump or pressure regulator (optional) Temperature (gas/environment) Gas connections sample continuous needle with integrated pump hose connection for ID 4 mm with integrated pump Inlet pressure pump pressure regulator L-version S-version max. 0.3 barg max. 10 barg pressureless...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.