Technical Specifications:
The Autoloop PRO is an automatic carousel designed for flame sterilizing up to four inoculation loops. It features a microprocessor-controlled system with a graphic dot-matrix display. Users can adjust flame sterilization time (1-15 seconds) and cooling time (1-45 seconds), with an optional foot pedal for additional sterilization. Safety features include temperature control, flame activation warning, cooling time indicator, tilt sensor, and residual heat display. The sterilization monitor has three intensity settings and an off switch, and the device automatically shuts off after 1 hour of inactivity.
Design and Usability:
Constructed from stainless steel and anodized aluminum, the Autoloop PRO is robust and resistant to extreme laboratory conditions. It is user-friendly, accommodating both right and left-handed users, with a graphic menu for quick function selection and real-time updates on flaming and cooling times.
Efficiency and Safety:
The device prevents unintentional use of hot loops by displaying cooling times and positions of cool loops. An intelligent sensor ensures safe sterilization, and the loop holder's position minimizes contamination. Precise flame control extends loop life and reduces gas consumption, enhancing efficiency.
Additional Features:
The Autoloop PRO includes coordinated mounts and optical detectors for loop holders, with start options for immediate operation or full rotation sterilization. It is compatible with Fuego SCS and gasprofi 1 SCS micro series burners, though a laboratory gas burner is not included.
Compliance and Warranty:
The device complies with CE standards EN 61326-1 and EN 61010, and EEC guidelines 2004/108/EC and 2006/95/EC. It comes with a 2-year warranty, excluding parts subject to wear and tear.
Overview:
The document outlines the Autoloop PRO's technical specifications and operational details, emphasizing ease of use, safety, and efficiency improvements.
Specifications:
The device supports 1 to 4 inoculation loop holders with optical detection and adjustable flame sterilizing times. Additional sterilization can be activated via an optional foot pedal.
Safety Features:
Includes temperature control, flame activation warning, cooling time indicator, tilt sensor, and residual heat display, with an adjustable sterilization monitor.
Construction and Compliance:
Made of stainless steel and aluminum, resistant to UV and solvents, and compliant with relevant CE and EEC standards.
Efficiency and Cost Savings:
The Autoloop PRO reduces working time by up to 70% compared to traditional methods, achieving cost-effectiveness after approximately 50 working hours.
Included Components:
Includes four inoculation loop holders, loops, a pedestal, a foot pedal connector, and an instruction manual. A laboratory gas burner is not included.
Optional Accessories:
Spare loop holders and loops, and a spray protector for enhanced safety are available.
See more

Catalog excerpts

Autoloop Pro-1

Technische Daten: mit 4 Impfösenhaltern 4 Impfösen Standfuß Fußpedalanschluss Bedienungsanleitung 2 Jahre Garantie Laborgasbrenner nicht im Lieferumfang enthalten includes 4 inoculation loop holders 4 inoculation loops Pedestal Foot pedal connector Instruction manual 2-year warranty Laboratory gas burner not included für Fuego SCS - Serie Art.-Nr. 8.000.400 for Fuego SCS - Series Art.-No. 8.000.400 für gasprofi 1 SCS micro - Serie Art.-Nr. 6.000.400 for gasprofi 1 SCS micro - Series Art.-No. 6.000.400 Ersatzimpfösenhalter aus Edelstahl, mit Überwurfmutter, für Impfösen mit Draht Ø 0,6 - 1 mm Spare inoculation loop holder made of stainless steel, with sleeve nut, for inoculation loops with wire Ø 0.6 - 1 mm Technik: Microprozessor Anzeige: vollgraphisches Dot-Matrix Display Drehrichtung: links / rechts, je nach Halterentnahme Impfösenhalter: 1 - 4, mit optischer Haltererkennung Einstellbare Ausglühzeit: 1 - 15 sec Einstellbare Abkühlzeit: 1 - 45 sec Zusätzl.Flammensterilisation: über Fußpedal (optional) Sicherheitseinrichtungen: Übertemperaturschutz Flammenaktivierungsanzeige Anzeige der verbleibenden Abkühlzeit Kippsensor, Restwärmeanzeige Einstellbarer Sterilisationsmonitor: 1 - aus 2 - niedrige Ausglühintensität 3 - mittlere Ausglühintensität 4 - hohe Ausglühintensität Stand by: automatische Geräteabschaltung: 1 h (oder mit Stand-By Zeit des Brenners) Spannungsversorgung: über Fußpedalbuchse des Brenners Gehäuse: Edelstahl & Almuninium, UV- und lösungsmittelbeständig Abmessungen: Bodenplatte (Art.-Nr. 8.000.400): 135 x 180 mm (B x T) Bodenplatte (Art.-Nr. 6.000.400): 135 x 135 mm (B x T) Höhe Autoloop : 305 mm Gewicht: Art-Nr.: 8.000.400: 1200 g Art-Nr.: 6.000.400: 1100 g CE: EN 61326-1, EN 61010 EWG Richtlinien: 2004/108/EG, 2006/95/EG Technical data: Spray protector for Autoloop for more safety when handling with pathogenic material PRO Art.-Nr./Art.-No. 6.000.210 Ersatzimpfösen aus Spezialedelstahl, Draht Ø 0,6 mm Spare inoculation loops made of special stainless steel, wire Ø 0.6 mm Öse i.Ø 1 mm / Loop int. Ø 1 mm Art.-Nr./Art.-No. 6.000.371 Öse i.Ø 3 mm / Loop int. Ø 3 mm Art.-Nr./Art.-No. 6.000.373 Öse i.Ø 5 mm / Loop int. Ø 5 mm Art.-Nr./Art.-No. 6.000.375 andere Größen auf Anfrage / other sizes on request 2004/108/EC 2006/95/EC (Verschleißteile ausgenommen) (Except parts to wear and tear) Spritzschutz für Autoloop für mehr Sicherheit im Umgang mit pathogenem Material Technology: Microprocessor Display: fully graphic dot-matrix Rotational direction: left / right, depends on removed holder Inoculation loop holder: 1 - 4, with optical holder detection Time of flame sterilizing: 1 - 15 sec Time for cool-down period: 1 - 45 sec Additional flame sterilization: by foot pedal (optional) Safety features: temperature control flame activation warning indicator of remaining cooling time tilt sensor, residual heat display Adjustable sterilization monitor: 1 - Off 2 - low intensity 3 - middle intensity 4 - high intensity Stand by: automatic unit switch off: 1 h (or with stand-by time of the burner) Operating voltage: via gas burner (foot pedal socket) Casing: stainless steel & aluminum, UV and solvent resistant Measurements: Pedestal (Art.-No. 8.000.400): 135 x 180 mm (w x d) Pedestal (Art.-No. 6.000.400): 135 x 135 mm (w x d) Height Autoloop : 305 mm Weight: Art-No. 8.000.400: 1200 g Art-No. 6.000.400: 1100 g CE: EN 61326-1, EN 61010 EEC guidelines: 2004/108/EC, 2006/95/EC Email: [email protected] • Internet: http://www.wld-tec.com (02/14, 8.999.514) Technische Änderungen vorbehalten / Specifications subject to change without notice Karussell zum Ausglühen von Impf

 Open the catalog to page 1
Autoloop Pro-2

Flammenzeit Sekundengenaue Einstellung der benötigten Flammensterilisationszeit Das vollautomatische Karussell zum Ausglühen von Impfösen. Das Ösenkarussell Autoloop , passend für bis zu 4 Impfösen, wurde nach aktuellen Bedürfnissen in Laboren der Mikrobiologie, Zellbiologie und Biotechnologie entwickelt. PRO Flame time Precise settings of the required flame sterilization time Abkühlzeit Je nach Impfösenmaterial kann die entsprechende Abkühlzeit sekundengenau eingestellt werden Cooling period The cooling time can be set for the inoculation loop material used - exact to the second Mehr Sicherheit...

 Open the catalog to page 2
Autoloop Pro-3

Flammenzeit Sekundengenaue Einstellung der benötigten Flammensterilisationszeit Das vollautomatische Karussell zum Ausglühen von Impfösen. Das Ösenkarussell Autoloop , passend für bis zu 4 Impfösen, wurde nach aktuellen Bedürfnissen in Laboren der Mikrobiologie, Zellbiologie und Biotechnologie entwickelt. PRO Flame time Precise settings of the required flame sterilization time Abkühlzeit Je nach Impfösenmaterial kann die entsprechende Abkühlzeit sekundengenau eingestellt werden Cooling period The cooling time can be set for the inoculation loop material used - exact to the second Mehr Sicherheit...

 Open the catalog to page 3
Autoloop Pro-4

Technische Daten: mit 4 Impfösenhaltern 4 Impfösen Standfuß Fußpedalanschluss Bedienungsanleitung 2 Jahre Garantie Laborgasbrenner nicht im Lieferumfang enthalten includes 4 inoculation loop holders 4 inoculation loops Pedestal Foot pedal connector Instruction manual 2-year warranty Laboratory gas burner not included für Fuego SCS - Serie Art.-Nr. 8.000.400 for Fuego SCS - Series Art.-No. 8.000.400 für gasprofi 1 SCS micro - Serie Art.-Nr. 6.000.400 for gasprofi 1 SCS micro - Series Art.-No. 6.000.400 Ersatzimpfösenhalter aus Edelstahl, mit Überwurfmutter, für Impfösen mit Draht Ø 0,6 - 1 mm...

 Open the catalog to page 4
Autoloop Pro-5

Speed-up Flame Sterilizing Inoculation Loops and Cut Down Your Costs! Case 1: Bunsen Burner & 1 Inoculation Loop Loop 1 4 sequences finished after 80 seconds Working with inoculation loop Flaming inoculation loop Time to change loops Cooling down period Case 2: Fuego SCS & 4 Inoculation Loops placed on a Tray Loop 1 Loop 2 Loop 3 Loop 4 Fall 3: Fuego SCS with Automated Caroussel Autoloop Pro & 4 Inoculation Loops (Optimized Flaming with Sterilization Monitor) Loop 1 Loop 2 Loop 3 Loop 4 Compared to Case 2 the Autoloop Pro has paid off after approx. 50 working hours!* * based on an hourly rate...

 Open the catalog to page 5

All WLD-TEC catalogs and technical brochures

  1. SteriMax

    4  Pages

  2. Flame 110

    4  Pages

  3. Flame 100

    4  Pages

  4. Fuego

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.