EVOLVE PROLINE
2Pages

{{requestButtons}}

Catalog excerpts

EVOLVE PROLINE - 1

Radial Head System: The Market Leader Now with plating options: introducing the EVOLVE® TRIAD™ Radial Head and Radial Neck Plates. Radial Head Plate Radial Neck Plate EVOLVE® PROLINE Radial Head System • Over 35,000 implanted1 • Independently studied: non-design team JBJS study from Oulu, Finland concludes that smooth stems and cemented bipolar designs should be considered superior to press-fit prosthesis2 • Smooth stem implant designs supported by two long term studies (12-year3 and 8-year4 average follow up) • Prospective data shows proven performance in two-year outcomes5 • Press-fit ingrowth designs have been shown to experience symptomatic loosening6 • Smooth stem design avoids ingrowth, and thereby avoids the need for a tight fit in fractured bone • Smooth stem design allows for dynamic adjustment, a biomechanical design rationale chosen because: EVOLVE® TRIAD™ Fixation System REFERENCES 1. Internal Sales Data 2. T. Flinkkilä, T. Kaisto, K. Sirniö, P. Hyvönen, J. Leppilahti, J. of Bone and Joint Surgery, Short-to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow. VOL. 94-B, No. 6, JUNE 2012 3. Harrington; Journal of Trauma. 2001 50:46-52 4. King; J. Bone Joint Surg. 2008;90:271-80. 5. Grewal; J. Bone Joint Surg. 2006;88:2192-2200 6. Cloke, Ali, Stanley; Early Failure of a Press-fit, Anatomical Radial Head Prosthesis; Shoulder & Elbow 2010; 2 p223 (Abstracts from 21st Annual Scientific Meeting, BESS) 7. Graham King, MD et al, An Anthropometric Study of the Radial Head. J of Arthroplasty, 2001. > “The native radial head lacks a consistently > “The native radial head is variably offset from the axis of the neck of the radius”7 • Modular stem and head design provides 324 size combinations to match variable anatomy • Simple design has no polyethylene, moving parts or set screws to wear out over time

Open the catalog to page 1
EVOLVE PROLINE - 2

Elbow Plating System with ORTHOLOC® Polyaxial Locking Think Elbow ® Think EVOLVE ORTHOLOC® Polyaxial Locking • Allows for screw placement in 30 degree cone - 15 degrees from center axis • No need to tap threads in plate interoperatively • Hardness differential between plate and screw increases locking strength EVOLVE® EPS Elbow Plating System • Polished stainless steel • ORTHOLOC® Polyaxial locking • Anatomically contoured low profile plate design • 90 or 180 degree humeral plating options For more information, visit wmt.com ™Trademarks and ®Registered marks of Wright Medical Technology,...

Open the catalog to page 2

All Wright Medical Technology catalogs and technical brochures

  1. FORCE FIBER

    4 Pages

  2. BIOFOAM®

    1 Pages

  3. TENSIX

    2 Pages

  4. ALLOPURE

    6 Pages

  5. MEDIALMAX

    2 Pages

  6. DARCO™

    1 Pages

  7. INVISION™

    2 Pages

  8. PROPHECY

    6 Pages

  9. css

    4 Pages

  10. CL AW ® II

    20 Pages