P/V1500 BLACK ANALOG PUMP
9Pages

{{requestButtons}}

Catalog excerpts

P/V1500 BLACK ANALOG PUMP - 1

TECHNICAL DATA SHEET V/P1500 Analog Black edition gas pumps 2. General information 3. General flow performance 4. Standard models 5. Electronic interface 8. Performance charts 9. Drawings

Open the catalog to page 1
P/V1500 BLACK ANALOG PUMP - 2

P/V1500 BLACK ANALOG PUMP Technical Datasheet BLACK EDITION MICRO PUMPS FROM XAVITECH Xavitech’s Black edition is our pump model with the most functionality and flexibility. Our goal is for you to be able to use this micro pump in your new system or as a drop-in replacement in your existing system easily and conveniently. The Black edition pumps are divided into two categories; The Analog edition and the Intelligent edition. The analog edition comes with a 3-cable connection and allows for analog control and can be used with our AFC for easy experimenting. GUARANTEED LIFETIME The...

Open the catalog to page 2
P/V1500 BLACK ANALOG PUMP - 3

P/V1500 BLACK ANALOG PUMP General flow performance Free flow: 1200 ml/min Maximum vacuum: -150 mbar Flow can be calibrated to deliver a certain flow at a certain vacuum level. Ask us for more information. Maximum pressure: 350 mbar Maximum vacuum: -350 mbar Free flow: 1200 ml/min Maximum pressure: 150 mbar Figure 1: General flow performance for Xavitech P1500 (left) and V1500 (right) pumps IMPORTANT NOTES Pump Flow: Flow is one-directional, it cannot be reversed Filters: To ensure lifetime, air filters should be used to prevent contaminations like dust to enter the pump Capacitor: Missing...

Open the catalog to page 3
P/V1500 BLACK ANALOG PUMP - 4

P/V1500 BLACK ANALOG PUMP Standard models STANDARD MODELS (PART NUMBER) LIFE TIME (Hours) ANALOG FLOW CONTROL CONNECTION INTERFACE FREE FLOW (ml/min) PART NUMBER MAXIMUM PRESSURE/ MAXIMUM VACCUM (mbar) Xavitech provides several pre-calibrated standard models. For these models, the voltage and the maximum flow is calibrated to standard values. When buying a standard pump, you still have a few choices you can make. Choose voltage, connection and lifetime. And if you’re pumping agressive gases you can chose Viton or Kalrez membranes. The chart below lists the standard pumps models that...

Open the catalog to page 4
P/V1500 BLACK ANALOG PUMP - 5

P/V1500 BLACK ANALOG PUMP Electronic interface Inside Pump 2.85 V DC Pull-up Molex 52610 or 52271 or similiar for flex cable Molex 530470510 for 3 or 5-wire connections Note: A VCC capacitor is required for 24-volt pumps * Serial interface applies on pump with flex or 5 wire connection Figure 2: Electronic interface INTERFACE DESCRIPTION Pump Cycle Maximum input voltage: Calibrated voltage + 0.5 V DC. The pump can be damaged otherwise. Minimum input voltage: 5 V DC. However, the pump performance is reduced if the voltage is set lower than calibrated value. Xavitech recommends to always run...

Open the catalog to page 5
P/V1500 BLACK ANALOG PUMP - 6

P/V1500 BLACK ANALOG PUMP I/O X This is a general I/O connected to an A/D converter of the microcontroller inside the pump. The default functionality is frequency control: • 0 – 0.05 V DC: Maximum frequency of the pump • 0.06 – 2.75 V DC: Frequency control of the pump • 2.75 – 2.85 V DC: Pump stops • Max input voltage: 3.3 V DC (the pump can be damaged if exceeded) Note that the frequency adjustment can only lower the frequency from the factory default frequency. Normally a pump is calibrated to have its maximum frequency (maximum flow) set as default at factory. The use of I/O X can be...

Open the catalog to page 6
P/V1500 BLACK ANALOG PUMP - 7

P/V1500 BLACK ANALOG PUMP CAPACITOR SPECIFICATIONS Xavitech recommends using a capacitor parallel to the power supply (see Figure 2) to reduce the power spikes generated by the electromagnetic motor. For 24-volt pumps, a VCC capacitor is required to not damage the pump. See the recommended capacitors sizes below. Recommended capacitator

Open the catalog to page 7
P/V1500 BLACK ANALOG PUMP - 8

P/V1500 BLACK ANALOG PUMP Performance charts PERFORMANCE CHARTS The charts show typical performance and are provided as a reference. Exact performance will differ between pump individuals. Flow (ml/min) Pressure (mbar) Pressure (mbar) Flow (ml/min) Flow (ml/min) Vacuum (mbar) (mbar) Vacuum Flow (ml/min) Flow (ml/min)

Open the catalog to page 8
P/V1500 BLACK ANALOG PUMP - 9

P/V1500 ANALOG BLACK PUMP BLACK EDITION P1500 AND V1500 WITH 3 OR 5 WIRE CONNECTION PUMP MODEL Drawing Scale Dimension Tolerance Pump Weight Recommended Connectors Recommended Tube Inner Diameter This information is accurate and reliable. However, specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. Xavitech products are not authorized for use as critical components in life support devices or systems without express written approval of Xavitech. © 2021 Xavitech - All Rights Reserved...

Open the catalog to page 9

All Xavitech AB catalogs and technical brochures

  1. Xavitech