P/V200 ORANGE AFFORDABLE
7Pages

{{requestButtons}}

Catalog excerpts

P/V200 ORANGE AFFORDABLE - 1

TECHNICAL DATA SHEET V/P200 Affordable Orange edition gas pumps 2. General information & flow performance 3. Standard models 4. Electronic interface 6. Pump parameters 7. Drawings

Open the catalog to page 1
P/V200 ORANGE AFFORDABLE - 2

P/V200 ORANGE AFFORDABLE PUMP Technical Datasheet ORANGE EDITION The orange edition is suitable for those who need a high quality micro pump with a lifetime of 5 000 hours. • High quality • Affordable solution • Guaranteed service lifetime GUARANTEED LIFETIME OF 5 000 HOURS With the Orange edition, you get a micro pump that is guaranteed to work for the full 5 000 hours it was designed to do, at a very good price. In this way, you do not need to pay for pumps with a longer lifetime in order to be assured that the pumps will actually work for the stated number of hours. HIGH QUALITY AT AN...

Open the catalog to page 2
P/V200 ORANGE AFFORDABLE - 3

P/V200 ORANGE AFFORDABLE PUMP Standard models STANDARD MODELS (PART NUMBER) ANALOG CONTROL MAXIMUM PRESSURE/ MAXIMUM VACCUM (mbar) FREE FLOW (ml/min) PART NUMBER The Orange version is only available in fixed voltages and cannot be customized with flow calibration. The lifetime is also fixed. Choose the Black edition if you need more flexible solutions.

Open the catalog to page 3
P/V200 ORANGE AFFORDABLE - 4

P/V200 ORANGE AFFORDABLE PUMP Electronic interface Molex 52610 or 52271or similiar for flex cable Note: A VCC capacitor is required for 24-volt pumps GND Figure 2: Electronic interface INTERFACE DESCRIPTION Pump Cycle Maximum input voltage: Calibrated voltage + 0.5 V DC. The pump can be damaged otherwise. Each pump is setup to run at 5 or 12 V DC. Minimum input voltage: 3.2 V DC. However, the pump performance is reduced if the voltage is set lower than calibrated value. Xavitech recommends to always run the pump at the calibrated voltage. Electromagnet ON Figure 3 shows in terms of current...

Open the catalog to page 4
P/V200 ORANGE AFFORDABLE - 5

P/V200 ORANGE AFFORDABLE PUMP up procedure which takes up to 3 s (depending on default pump frequency) when the power is turned on. During this time, the pump adjusts the stroke length to reach its calibrated length. The regulation adjusts the stroke length for every pump stroke thus it depends on the pump frequency. CAPACITOR SPECIFICATIONS Xavitech recommends using a capacitor parallel to the power supply (see Figure 2) to reduce the power spikes generated by the electromagnetic motor. For 24-volt pumps, a VCC capacitor is required to not damage the pump. See the recommended capacitors...

Open the catalog to page 5
P/V200 ORANGE AFFORDABLE - 6

P/V200 ORANGE AFFORDABLE PUMP Performance charts PERFORMANCE CHARTS The charts show typical performance and are provided as a reference. Exact performance will differ between pump individuals. Flow (ml/min) Pressure (mbar) Flow (ml/min) Vacuum (mbar) Vacuum (mbar) Flow (ml/min) Flow (ml/min)

Open the catalog to page 6
P/V200 ORANGE AFFORDABLE - 7

P/V200 ORANGE AFFORDABLE PUMP ORANGE EDITION P200 AND V200 WITH 2 WIRE CONNECTION PUMP MODEL Drawing Scale Dimension Tolerance Pump Weight Recommended Connectors Recommended Tube Inner Diameter This information is accurate and reliable. However, specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. Xavitech products are not authorized for use as critical components in life support devices or systems without express written approval of Xavitech. © 2021 Xavitech - All Rights Reserved...

Open the catalog to page 7

All Xavitech AB catalogs and technical brochures

  1. Xavitech

    27 Pages