video corpo

Easy
1 /1Page

Easy

Easy
1 /1Page

Catalog excerpts

Easy-1

SHALYA Complete range of electro surgical solutions... Helping you make the right choice.. Add Hi-Tech Precision to your Surgical Expertise... Technical Specifications of SHALYA Monopolar Cut: Pure Sine wave 390 kHz Sp Cut- Programmable Pulse or continues output 250 W at 300 Ù, CF 1.5 Pure - Continues output, 250 W at 300 Ù, CF 1.5 Blend - Bursts repeating at 29 kHz 55% ON cycle, 150 W at 300 Ù, CF 2.5 Monopolar Coag : Damped Sine wave 460 kHz Soft - Repetition Frequency 62 kHz, 100 W at 500 Ù, CF 5.0 Fulgurate - Repetition Frequency 52 kHz, 100 W at 500 Ù, CF 6.5 Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz, 100 W at 500 Ù, CF 8.0 Bipolar : Pure Sine wave 390 kHz Micro - Lower output voltage, 60 W at 100 Ù, CF 1.5 Macro - Higher output voltage, 60 W at 100 Ù, CF 1.5 DESIGN STANDARD Classification according to the EC-Directive 93/ 42/ EEC : II b Protective class according to EN 60 601-1 : I Type according to EN 60 601-1 : CF LEAKAGE CURRENTS • RF leakage current • Monopolar : < 150 mA rms • Bipolar : < 60 mA rms • Low frequency leakage currents • Normal polarity, intact ground : < 10 µ • Normal polarity, ground open : < 50 µA PREM SYSTEM Measuring Frequency : 85 kHz ± 10 kHz Measuring current : < 10 µA Acceptable Resistance Range Dual Area PREM Patient Return Electrode : 10-135 Ù Single Area Patient Return Electrode : < 10 Ù FEEDBACK SYSTEM • 3 Microprocessor Controlled 6SENSE Technology with sampling rate above 2000 sense/second • Maximum output power deviation < 15% or 5 watts, whichever is greater at any setting with PER-97 INPUT POWER Operating Voltage : 190-265 Volt AC, (other ratings available on request) Max. Power input : 1000 VA, Fuse : 4 A DIMENSIONS L x W x H in cm - 38.0 x 30.5 x 11.5, Extended Range Features of SHALYA 6SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology. PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns. Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area. Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any. Bipolar Cut : Macro mode can be used for bipolar cutting with hooks and other cutting devices. Argon Beam Coagulator up-gradable : ESU can be upgraded for Argon Beam Coagulation module. User Programmable : THREE Surgical Programs help in setting the system after power ON. BiCoag Alarm (Optional) : Audio feedback at completion of Bipolar coag, reduces charring and sticking. electro surgical Sp Cut : Low voltage cut mode for cutting with minimum smoke & charring for endoscopic procedure. Soft/Dissect Coag : Faster cutting with coagulation for thicker tissues & soft coagulation. 3057, Bhandup Indl. Estate, Pannalal Compound, LBS Marg, Bhandup (W), Mumbai - 400 078. India • Tel : +91-22-2596 4645 / 3299 5113 Email : [email protected]

 Open the catalog to page 1

Archived catalogs

  1. Shalya Lx

    2  Pages

  2. Shalya Easy

    2  Pages

  3. Shalya Mx

    2  Pages

  4. Shalya Dx

    2  Pages

  5. Shalya Easy +

    2  Pages

  6. APC

    1  Page

  7. Products

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.