Shalya TURoSeal - Technical Specifications... MONOPOLAR CUT Pure Sine wave 390 kHz Sp Cut - Programmable Pulse or continues output, 300 W at 300 Ω, CF 1.5 Pure - Continues output, 300 W at 300 Ω, CF 1.5 Blend - Bursts repeating at 29 kHz 55% ON cycle, 200 W at 300 Ω, CF 2.5 MONOPOLAR COAG Damped Sine wave 460 kHz Soft - Repetition Frequency 62 kHz, 120 W at 500 Ω, CF 5.0 Fulgurate LCF - Repetition Frequency 42 kHz, 120 W at 500 Ω, CF 6.2 Fulgurate HCF- Repetition Frequency 34 kHz, 120 W at 500 Ω, CF 7.0 Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz, 120 W at 500 Ω, CF 8.0 BIPOLAR Pure Sine wave 440 kHz Micro - Lower output voltage, 95 W at 100 Ω, CF 1.5 Macro - Higher output voltage, 95 W at 100 Ω, CF 1.5 SEAL MODE Pure Sine wave 440 kHz Seal - Pulse output mode, 5 level, 150 W at 100 Ω, CF 1.5 Bip Coag - Medium output voltage, 120 W 100 Ω, CF 1.5 Bip Cut - Higher output voltage, 120 W 100 Ω, CF 1.5 SALINE RESECTION (BITUR) MODE : Sine wave 440 kHz Saline Cut. - Continues output, 300 W at 100 Ω, CF 1.5 Saline Coag - Continues output, 120 W at 100 Ω, CF 1.5 PREM SYSTEM Measuring Frequency : 85 kHz ± 10 kHz Measuring current : < 10 µA Acceptable Resistance Rang upto 40% Dual Area PREM Patient Return Electrode : 5-135 Ω (Adaptive) Single Area Patient Return Electrode : < 10 Ω FEEDBACK SYSTEM • 3 Microprocessor Controlled 6 SENSE Technology with sampling rate above 4000 sense/second • Maximum output power deviation < 15% or 5 watts, whichever is greater at any setting with PER-98 DESIGN STANDARD Classification according to the EC- Directive 93/ 42/ EEC: Class IIb General Safety Standards: IEC 60601-1-1, IEC 60601-2-2 EMI/EMC Compatibility Standard: IEC 60601-1-2 IS Safety Standard: IS 7583 LEAKAGE CURRENTS • RF leakage current • Monopolar : < 150 mA rms • Bipolar : < 60 mA rms • Low Frequency leakage currents • Normal polarity, intact ground : < 10 µA • Normal polarity, ground open : < 50 µA INPUT POWER Operating Voltage : 180-265 Volt AC, (other ratings available on request) Max. Power input : 1000 VA, Fuse : 4 A, UPS Backup : 1.5KVA DIMENSIONS L x W x H in cm - 45.0 x 35.5 x 11.5, Note : Unit is available in other HF power ratings on request. Extended Range Add Hi-Tech Precision to your Surgical Expertise... Complete range of electro surgical solutions... XcelLance Medical Technologies Pvt. Ltd. Helping you make the right choice.. Plot No. W239, Rabale MIDC,TTC Industrial Area, Rabale, Navi Mumbai - 400 701. INDIA T:+91-22-2760 2261 / 2 / 3, F: +91-22-2760 2263 E: info@shalya

Open the catalog to page 1
Turoseal Brochure - 2

Complete range of electro surgical solutions... Vessel Seal Module Innovative technology to seal the artery, vein and tissue bundle by applying calibrated pressure with RF energy. 10mm reusable instruments with changeable blade Sealing Instruments The Collagen & Elastin within the tissue vessel wall melts & restructures to form translucent seal. System senses the density of tissue held in the instrument & delivers an appropriate amount of energy to form the permanent seal. Vseal-M : Open clamp Vseal-C : Sealing clamp Vseal-5L : Lapro 5mm reusable instruments 5mm Vseal-5S : Open surgery...

Open the catalog to page 2
Turoseal Brochure - 3

Coag Modes : These modes offer every range of coagulation ability required for today's modern surgeries. Desiccate : Specifically designed for contact coagulation at lower voltages, hence suitable for Neuro, ENT & Endoscopy cases. Fulgurate : Suitable for non contact coagulation with moderate sparking in variety of applications such as cardiothoracic surgeries. Electrosurgery Module Spray Coag : Non touch coagulation for large areas with minimum depth of tissue damage & necrosis. Useful in Lever, Cancer & Trauma. Effect Modes - Plotted response as the tissue demands... Vessel Seal / Bipolar...

Open the catalog to page 3
Turoseal Brochure - 4

Complete range of electro surgical solutions... Saline Instruments Saline Plasma Module A Plasma Corona generated in saline medium due to discharge of highly energized electric current. The mobility of ions around the loop creates a cutting effect. Sufficient amount of haemostasis enables coagulation of the capillary bleeders with resection. By applying low voltage energy, resistive heating of tissue achieves coagulation and the depth is controlled by firm application of pressure with sufficient amount of time to control the bleeders. Shalya Saline working elements with isolated sheath...