Overview: The Alyza IQ analyzers are designed for measuring phosphate (PO4) and ammonium (NH4) levels with minimal reagent use, simple maintenance, and reliable data output. They integrate seamlessly with the IQ Sensor Net systems.
Key Features:
  • Low reagent consumption and waste reduction.
  • Simple maintenance requiring only 10 minutes every three months.
  • Reliable results across a wide range of measurements.
  • Easy reagent replacement with no-drip pouches.
  • Available in one- and two-channel versions.
  • Optimized user interface with self-diagnostics.
Measurement Methods:
  • Ammonium Measurement: Utilizes the Indophenol method, resulting in a blue coloration analyzed photometrically. Suitable for wastewater treatment and river monitoring.
  • Orthophosphate Measurement: Employs the Molybdate-Vanadate method, producing a yellow color analyzed at 420 nm. Used in wastewater treatment and precipitation control.
Applications:
  • Wastewater treatment plant effluent monitoring with high accuracy at low concentrations.
  • River monitoring with long reagent life and minimal maintenance.
  • Precipitation control with automatic cleaning and cost reduction.
Configuration Examples: The Alyza IQ can be configured with various IQ Sensor Net systems, such as System 2020 and System 282/284, without needing additional power supply modules.
Technical Data:
  • Measurement ranges for NH4: 0.02-4.00 mg/l and 0.10-20.00 mg/l.
  • Measurement ranges for PO4: 0.02-15.00 mg/l and 0.2-50.0 mg/l.
  • Automatic cleaning and calibration features.
  • Operational temperature range: -4 to 104 °F (-20 to +40 °C).
Ordering Information: Various models and reagent sets are available for both NH4 and PO4 measurements, with specific order numbers provided for each configuration.
Company Information: Xylem is a global leader in water technology, providing solutions for water challenges through advanced technology and analytics. They offer a wide range of products and services for different sectors, including public utilities and industrial applications.
See more

Catalog excerpts

Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-2

How much reagent does Less Reagents Minimized reagent consumption and waste Simple Service Regular maintenance takes just 10 minutes every 3 months Better Data Reliable results from low to high measuring levels Simple Service Built with Service in mind, all service items can be quickly and easily exchanged without calling a service technician or service contracts. Long Life Reagents Easy and safe reagent replacement with no-drip reagent pouches.

 Open the catalog to page 2
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-3

The advantages • Measurement of PO4 or NH4 • High accuracy at low measuring ranges • Extremely low reagent consumption • Connectable to the IQ Sensor Net (provides 10 W) • Installation of PO4 and NH4 analyzer directly at the basin • One- and Two-channel versions available • Safe and easy replacement of reagents • Optimized user interface and self diagnostics • Minimum maintenance and easy handling Clear Information Clear measurement menu - even for 2 channel versions and monitoring of reagent life time. The Alyza IQ is fully integrated into the IQ Sensor Net as a sensor. The new analyzer can...

 Open the catalog to page 3
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-4

Ammonium measurement Method Indophenol method according to DIN 38 406 As the name suggests, the Indophenol method results in a blue coloration of the sample. The color is generated by the reaction of ammonium ions from the sample with hypochlorite ions and carbolic acid or a carbolic acid derivative under alkaline conditions (pH approx. 12.6). For acceleration of the reaction, a catalyst is used. The reaction can be sped up further by increasing the temperature of the reaction solution. The colored sample then is analyzed photometrically in the red spectral range. The higher the ammonium concentration,...

 Open the catalog to page 4
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-5

Orthophosphate measurement Method Molybdate-Vanadate method (Yellow method) In the Molybdate Vanadate process, Orthophosphate (dissolved PO43-) is detected. Thereby, a color reagent consisting of Molybdate and Vanadate is added to the sample. Under acid consitions, the PO43- ions are integrated into the generated polyanions. The intensity of the occurring yellow color depends on the concentration of PO43-. Subsequently, the sample is analyzed in the photometer at approx. 420 nm. Precipitation control • Automatic cleaning reduces maintenance effort and increases operational safety • Reduction...

 Open the catalog to page 5
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-6

Order no. 470022 480008 480042 user selected Example configuration MIQ/TC 2020 3G MIQ/JB SACIQ-7,0 IQ Sensors Example configuration DIQ/S 284-CR6 MIQ/JB SACIQ-7,0 IQ Sensors Order no. 472130 480008 480042 user selected expansion) • Alyza IQ NH4 (Analyzer incl. SNCIQ cable and power supply) Additional hardware required: • 3 SACIQ (sensor cables) • 3 IQ sensors (e.g. turbidity, pH, oxygen) • DIQ/S 284-CR6 (controller) • Alyza IQ PO4 (analyzer incl. SNCIQ cable and power supply) Additional hardware required: • 2 SACIQ (sensor cables) Neither example 1 nor example 2 needs a power supply module MIQ/PS,...

 Open the catalog to page 6
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-7

For further technical data please see datasheets D2.24 and D2.25 Model Description Order no. Alyza IQ for Ammonium measurement Alyza IQ NH4-111 NH4 analyzer, 1-channel, with 2 measuring ranges, Indophenol method, connectable to 825011 IQ Sensor Net Systems 2020 and 282/284, provides 10 W to the IQ Sensor Net; including 2m SNCIQ cable; reagnet sets need to be ordered separately Alyza IQ NH4-112 NH4 analyzer, 2-channel, with 2 measuring ranges, Indophenol method, connectable to 825012 IQ Sensor Net Systems 2020 and 282/284, provides 10 W to the IQ Sensor Net; including 2m SNCIQ cable; reagnet sets...

 Open the catalog to page 7
Alyza IQ: The Simple choice for PO4 and NH4 Analyzers-8

Xylem |'zil0nn| 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We're a global team unified in a common purpose: creating advanced technology solutions to the world's water challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services settings. Xylem also provides a leading portfolio of...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.