Capillary Viscometry - 1

Catalogue Viscometry ViscoSystem® | AVS® | ViscoClock | Viscometers

Open the catalog to page 1
Capillary Viscometry - 2

Capillary viscometry from SI Analytics – know-how from the very beginning Innovative capillary viscometry – Further developments and improve- The viscosity of Newtonian fluids can be most precisely determined using capillary viscometers. This method of measurement, measures the time taken for a defined quantity of fluid to flow through a capillary with a known diameter and known length. With the industrial production of such precisely calibrated capillary viscometers, we have created the conditions to enable this measuring method to establish itself instru-ments and accessories led to a...

Open the catalog to page 2
Capillary Viscometry - 3

Content viscometry Applications for AVS® measurement systems Page 4 WinVisco 370 software Page 16 CT 72 Transparent Thermostats Page 26 Viscometers and their range of use Page 30 Ubbelohde viscometers, normal form (DIN) Page 31 Ubbelohde viscometers, normal form (ASTM) Page 32 Ubbelohde viscometers, with additional tube and threads Page 33 Ubbelohde viscometers with TC sensors Page 34 Micro-Ubbelohde viscometers with TC sensors Page 36 Micro-Ubbelohde viscometers Page 37 Cannon-Fenske viscometers Page 38 Ostwald viscometers Page 40 AVS* measuring stands Page 46

Open the catalog to page 3
Capillary Viscometry - 4

AVS® measurement systems within quality assurance systems Business sector Automotive engineering motor oil (fresh and used) high polymer plastics original wort hop-wort bumpers beer beer Electrical engineering and electronics high polymer plastics of all types chips, casings Power supply transformer oil Plastics manufacturers high polymer plastics of all types Plastics processors high polymer plastics of all types injection molding Food industry instant flour thickeners jelly bears packaging materials yogurt containers milk products yogurt drink fruit and fruit juice concentrates...

Open the catalog to page 4
Capillary Viscometry - 5

Polymer applications for the AVS® measurement systems Polymers, their applications and utilization of our automatic systems Suitability of the AVS® measurement systems Operating temperature SNV 195598 DIN EN 60450 ASTM D 4243 ISO 5351 AST; D 1795 SCAN CM 15:99 TAPPI T230-0M99 Polybutylene terephthalate Decahydro -naphthalene Polyethylene terephthalate Polyethylene terephthalate Polyethylene terephthalate Dichloroacetic acid Polymethyl methacrylate Polyvinyl chloride Styrene-acrylonitrile copolymer Ethyl methyl ketone EWN Cuen (CED) Cuen (CED) Cuen (CED) Cuen (CED) Cuen (CED) Cuen (CED)...

Open the catalog to page 5
Capillary Viscometry - 6

ViscoCIock. If you need more accuracy: The ViscoClock is the economically priced introductory model in the field of automatic viscosity measurements. Manual measurements with a stopwatch and a trained eye is something of the past because time is money. The ViscoCIock The ViscoClock is an electronic time-measuring unit used to determine abso-lute and relative viscosity. It consists of a stand which is used to mount a viscometer and the electronic measuring unit. The two measuring levels are integrated in the stand made of high-quality PPA synthetic material, and the electronic measuring unit...

Open the catalog to page 6
Capillary Viscometry - 7

Technical data ViscoCIock Measuring range - time Accuracy of time measurement ± 0.01 s / ± 1 digit; however no more precise than 0.1 %; indicated as measuring uncertainty with a confidence level of 95 % Measuring range - viscosity 0.35 to10,000 mm²/s (cSt) the absolute, kinematic viscosity is additionally dependent on the uncertainty of the numerical value of the viscometer constant and on the measuring conditions, in particular the measuring temperature. 5-digit LCD display, 20 x 48 mm (H x W), digit height 12.7 mm, seconds indication with 2 decimal digits after the decimal point,...

Open the catalog to page 7
Capillary Viscometry - 8

Precise Capillary Viscometry – Easy, Flexible and Independent: AVS® 470 No PC needed: “Suction” and “Pressure” measurements P erfectly equipped for fully with just one instrument automatic viscosity measurements The AVS® 470 is the first viscosity measurement device that The AVS® 470 is a measuring system that includes almost allows “suction” and “pressure” measurements completely everything you need to take precise and ­ eproducible mear independent of a PC. This allows for maximum indepen- surements. All common types of viscosity calculation are dence and flexibility; set up a measuring...

Open the catalog to page 8
Capillary Viscometry - 9

“Suction” or “Pressure”? Preferred applications in comparison “Pressure” highly viscous samples e.g. oils, polymers Solvents: (examples) highly volatile Sulfuric acid Dichloroacetic acid Toluene Hexafluoro-isopropanol m-cresol Formic acid S imple and updateable Modular Concept The AVS® 470 is of a modular design and an optional optical or TC version ViscoPump II module. You can use your existing accessories such as thermostats, ­ A utomatic and highly precize measurements – independent of a PC ®  470 S stands, flow-through coolers or automatic cleaners e.  g. " Suction" and "pressure"...

Open the catalog to page 9
Capillary Viscometry - 10

AVS® 470 - Precise and Reliable ^ Working with the AVS® 470 is easy The desired measurement method can be preselected and started on the device. The entire measurement is automatic to eliminate subjective measurement errors. Once the set pre-heating time is reached, the desired number of mea- surements are taken and the viscometer automatically cleaned if required.The status of the measurements is con- tinuously displayed. If required, individual parameters may be input via an included PS 2 keyboard. A serial printer can be used to print measurement logs. The connections are on the front...

Open the catalog to page 10
Capillary Viscometry - 11

Technical data Clear user guidance, clear status - even without PC! UiscoPunp Check After switching on the AVS® 470 a self test is run and then an entry prompt appears. The parameters can be set in the test mode. The t0 value is determined automatically. punp power: All setup parameters can be preset conveniently e.g. pressure/suction, velocity waiting time between two tests, etc. result, carr-. stand. dev,= The readings can be read off conveniently on the display regardless of whether or not Measuring range (time) up to 9,999.99 s; resolution 0.01 s Measuring range (viscosity)pressure:...

Open the catalog to page 11